CoChat

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Comparison between Automatic and Fixed Positive Airway Pressure Therapy in the Home

Abstract

We tested the hypothesis that continuous positive airway pressure (CPAP) use and outcomes can be improved by an autotitrating CPAP device in patients with obstructive sleep apnea–hypopnea syndrome (OSAHS) who require higher CPAP (10 cm H2O or more). In this multisite randomized single-blind cross-over study, 44 patients (mean age, 49 ± 10 years) were randomized to 6 weeks at laboratory-determined fixed pressure and 6 weeks on autotitrating CPAP. Average nightly use was greater in automatic mode (306 versus 271 minutes, p = 0.005); median and 95th centile pressures in automatic mode were lower (p < 0.002). Automatic CPAP resulted in better SF-36 Vitality scores (65 ± 20 versus 58 ± 23, p < 0.05) and mental health scores (80 ± 14 versus 75 ± 18, p < 0.05), but no significant difference in Epworth score (p = 0.065). During automatic therapy, patients reported more restful sleep, better quality sleep, less discomfort from pressure, and less trouble getting to sleep for both the first week of therapy and for the averaged scores for Weeks 2–6 (all p values < 0.006). Patients who require higher fixed CPAP use autotitrating CPAP more and report greater benefit from this therapy.

Overview

Integrity signals

Registry

Crossref · 10.1164/rccm.200201-022oc

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 39 references

Research works printed but not linked: 6

  1. 2000, Sleep, 23, S102
  2. 1982, Am Rev Respir Dis, 126, 625
  3. 2001, Sleep, 24, 96, 10.1093/sleep/24.1.96 · DOI · Paper page
  4. 1994, Eur Respir J, 7, 1776, 10.1183/09031936.94.07101776 · DOI
  5. 2000, Sleep, 23, 645
  6. 2000, Sleep, 23, S150

Cited by

See all 178

Metadata

Authors
Massie, C. A., McArdle, N., Hart, R. W., Schmidt-Nowara, W. W., Lankford, A., Hudgel, D. W., Gordon, N., & Douglas, N. J.
Affiliations
The University of Western Australia (AU)
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2003-01-01
Volume
167
Issue
1
Pages
20-23
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2103235422
Cited by
177
References
39
Citations by year
2025: 4 · 2023: 3 · 2022: 1 · 2021: 3 · 2020: 5 · 2019: 2 · 2018: 2 · 2017: 5 · 2016: 2 · 2015: 9 · 2014: 8 · 2013: 10 · 2012: 9
FWCI
5.00
Type
journal article
Language
en
Open access
closed
Locations
  • American Journal of Respiratory and Critical Care Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
Keywords
continuous positive airway pressure, obstructive sleep apnea-hypopnea syndrome, CPAP titration, CPAP adherence, sleep quality, quality of life, daytime sleepiness, patient-reported outcomes
MeSH terms
Adolescent, Adult, Aged, Female, Home Care Services, Humans, Male, Middle Aged, Positive-Pressure Respiration, Quality of Life, Sleep, Treatment Outcome, Cross-Over Studies, Sleep Apnea, Obstructive

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison between Automatic and Fixed Positive Airway Pressure Therapy in the Home. https://app.cochat.ai/papers/10.1164/rccm.200201-022oc
The paper
Massie, C. A., McArdle, N., Hart, R. W., Schmidt-Nowara, W. W., Lankford, A., Hudgel, D. W., Gordon, N., & Douglas, N. J. (2003). Comparison between Automatic and Fixed Positive Airway Pressure Therapy in the Home. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.200201-022oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.