CoChat

Treatment of Obstructive Sleep Apnea With a Self-Titrating Continuous Positive Airway Pressure (CPAP) System

Sharma, S., Wali, S., Pouliot, Z., Peters, M., Neufeld, H., Kryger, M. · 1996 · Sleep
Cited by 69

The DOI matches its Crossref record.

Abstract

Conventional manually adjusted continuous positive airway pressure (CPAP) is an effective therapy for sleep-disordered breathing. We prospectively investigated the efficacy of a self-titrating nasal CPAP system in the acute treatment of obstructive sleep apnea (OSA) syndrome. Twenty patients with moderately severe OSA [apnea hypopnea index (AHI) > 15/hour] were enrolled in a randomized, controlled, prospective clinical trial. An initial diagnostic sleep study was performed, followed by randomization to a manually adjusted CPAP titration on one night and self titrating CPAP on the other night. On the conventional CPAP night, the CPAP was manually adjusted until abolition of all apneas and electroencephalographic (EEG) arousals, whereas the self-titrating CPAP was set in automatic mode at lights out. The self-titrating CPAP system utilized an algorithm based on airway vibration patterns to detect airway stability. The AHI decreased from 50.8 +/- 28.8/hour [mean +/- standard deviation (SD)] at baseline to 3.8 +/- 3.1/hour (p < 0.005) during manually adjusted and 6.1 +/- 5.3/hour (p < 0.005) during self-titrating CPAP. The arousal index (Ar-I) decreased from 34.1 +/- 23.1/hour (baseline) to 11.2 +/- 5.0/hour on manual adjustment (p < 0.005) and 11.3 +/- 0.3/hour on self titration (p < 0.005), whereas total sleep time was unchanged. No significant differences in any measure of oxygenation or sleep architecture were observed between the manually adjusted and self-titrating CPAP nights except that the lowest arterial oxygen saturation (SaO2) was higher with manual titration (84.4 +/- 4.2% vs. 79.9 +/- 9.7%, p < 0.05). The maximum pressure required for abolition of apneas and arousals was significantly lower (p < 0.05) during the self-titrating study (10.1 +/- 3.8 cmH2O) as compared to manually adjusted CPAP (12.3 +/- 3.9 cmH2O). Failure to increase pressure and failure to maintain minimum pressure occurred in 7 of the 20 subjects during the self-titrating study. This required manual resetting of the system in five subjects, but the system self-corrected in two subjects. An unsupervised study would have resulted in undertreatment of OSA. Based on a single-night laboratory study, self-titrating CPAP was well tolerated and improved OSA and sleep architecture comparable to manually adjusted CPAP. The future modifications of this prototype will require further research to assess its efficacy and safety in the laboratory and home environments before its recommendation for general long-term use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/sleep/19.6.497

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 69

Metadata

Authors
Sharma, S., Wali, S., Pouliot, Z., Peters, M., Neufeld, H., & Kryger, M.
Venue
Sleep
Published
1996-08
Volume
19
Issue
6
Pages
497-501
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W109061776
Cited by
69
References
0
FWCI
2.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Treatment of Obstructive Sleep Apnea With a Self-Titrating Continuous Positive Airway Pressure (CPAP) System. https://app.cochat.ai/papers/10.1093/sleep/19.6.497
The paper
Sharma, S., Wali, S., Pouliot, Z., Peters, M., Neufeld, H., & Kryger, M. (1996). Treatment of Obstructive Sleep Apnea With a Self-Titrating Continuous Positive Airway Pressure (CPAP) System. Sleep. https://doi.org/10.1093/sleep/19.6.497

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.