CoChat

Autoadjusting CPAP Therapy Based on Impedance Efficacy, Compliance and Acceptance

RANDERATH, WINFRIED J., SCHRAEDER, OLIVER, GALETKE, WOLFGANG, FELDMEYER, FRANK, RÜHLE, KARL-HEINZ · 2001 · American Journal of Respiratory and Critical Care Medicine

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

Constant continuous positive airway pressure (CPAP) is the treatment of choice for the obstructive sleep apnea syndrome (OSAS). To enable the pressure to be matched more accurately to actual requirements, and thus increase patient acceptance, an autoadjusting device based on the measurement of upper airway impedance was developed (APAPFOT). We investigated the efficacy and compliance in continuous use at home. Fifty-two patients were treated (randomized crossover) with CPAP and APAPFOT for 6 wk each. Respiratory disturbances, sleep profile, and arousals improved significantly with both modes (AHI: baseline, 35.1 ± 26/h; APAPFOT, 5.0 ± 5.2; CPAP, 4.3 ± 6.3; p < 0.001 baseline versus each mode). The mean pressure with APAPFOT was significantly reduced as compared with CPAP (CPAP, 7.8 ± 1.5 cm H2O; APAPFOT, 5.7 ± 1.8 cm H2O; p < 0.001). Under APAPFOT the pressure was lower than that under CPAP for 81.5 ± 21% of the time. Although overall use did not differ, 75% of the patients preferred APAPFOT for home treatment. We conclude that APAPFOT is as efficacious as constant CPAP in the treatment of OSAS. The treatment pressure can be reduced significantly, and sleep microstructure improved with APAPFOT. These might be the reasons for patient preference of automatic therapy.

Overview

Integrity signals

Registry

Crossref · 10.1164/ajrccm.163.3.2006168

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 28 references

Research works printed but not linked: 1

  1. Hoster, 1996, Influence of automated self-setting CPAP systems on sleep and breathing in sleep apnea syndrome., Wien Med Wochenschr, 146, 385

Cited by

See all 143

Metadata

Authors
RANDERATH, W. J., SCHRAEDER, O., GALETKE, W., FELDMEYER, F., & RÜHLE, K.-H.
Affiliations
Witten/Herdecke University (DE)
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2001-03-01
Volume
163
Issue
3
Pages
652-657
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W1975723518
Cited by
143
References
28
Citations by year
2025: 3 · 2024: 2 · 2023: 2 · 2022: 2 · 2021: 5 · 2020: 4 · 2019: 6 · 2018: 2 · 2017: 6 · 2016: 3 · 2014: 4 · 2013: 4 · 2012: 5
FWCI
6.59
Type
journal article
Language
en
Open access
closed
Locations
  • American Journal of Respiratory and Critical Care Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
Keywords
auto-titrating CPAP, paracetamol, obstructive sleep apnea, CPAP adherence, patient acceptance, sleep microstructure, arousal
MeSH terms
Female, Humans, Male, Middle Aged, Patient Compliance, Positive-Pressure Respiration, Prospective Studies, Electric Impedance, Cross-Over Studies, Sleep Apnea, Obstructive

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Autoadjusting CPAP Therapy Based on Impedance Efficacy, Compliance and Acceptance. https://app.cochat.ai/papers/10.1164/ajrccm.163.3.2006168
The paper
RANDERATH, W. J., SCHRAEDER, O., GALETKE, W., FELDMEYER, F., & RÜHLE, K.-H. (2001). Autoadjusting CPAP Therapy Based on Impedance Efficacy, Compliance and Acceptance. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.163.3.2006168

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.