A Laboratory Validation Study of the Diagnostic Mode of the Autoset™ System for Sleep-Related Respiratory Disorders
The DOI matches its Crossref record.
Abstract
We performed a validation study of the diagnostic mode of the Autoset system (ResMed, Australia) on a group of 44 snorers (10 women). We compared the result of the Autoset's automatic analysis of nasal airflow (using nasal prongs) to those of an in-laboratory polysomnographic study with a Fleisch facemask pneumotachograph. For the first 29 patients, the Autoset software was set to recognize only apneas; for the remaining 15, the software was modified to recognize both apneas and hypopneas. Relative to polysomnography, the Autoset overestimated the number of apneas. Oral breathing or displacement of the nasal prongs partially explained these differences. A significant correlation was found between the apnea indices (AI) assessed by the two methods (r = 0.98). For an AI of 20/hour the Autoset was 100% sensitive and 88% specific. The Autoset significantly underestimated the number of hypopneas compared to the polysomnograph with pneumotachograph (62.9 +/- 4.7 vs. 85.5 +/- 73.1, P = 0.04), although for an apnea-hypopnea index of 20, Autoset was 100% sensitive and 88% specific. The lack of linearity of Autoset's volume evaluation at low volumes could explain most of the differences. Our results indicate that the Autoset system, in its diagnostic mode, is a useful tool for identifying patients with significant obstructive sleep apnea syndrome. The system is less useful in patients with mild to moderate sleep disordered breathing, where it may give erroneous results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Long-term Use of CPAP Therapy for Sleep Apnea/Hypopnea Syndrome
McARDLE, N., DEVEREUX, G., HEIDARNEJAD, H., ENGLEMAN, H. M., MACKAY, T. W., & DOUGLAS, N. J. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.4.9807111 · Cited by 820
Home Diagnosis of Sleep Apnea: A Systematic Review of the Literature
Flemons, W. W., Littner, M. R., Rowley, J. A., Gay, P., Anderson, W. M., Hudgel, D. W., McEvoy, R. D., & Loube, D. I. (2003) · Chest · doi:10.1378/chest.124.4.1543 · Cited by 571
Flemons, W. W. (2002) · New England Journal of Medicine · doi:10.1056/nejmcp012849 · Cited by 362
Autoadjusting CPAP Therapy Based on Impedance Efficacy, Compliance and Acceptance
RANDERATH, W. J., SCHRAEDER, O., GALETKE, W., FELDMEYER, F., & RÜHLE, K.-H. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.3.2006168 · Cited by 143
Prevalence of Sleep Apnea Syndrome in Lone Atrial Fibrillation
Porthan, K. M., Melin, J. H., Kupila, J. T., Venho, K. K. K., & Partinen, M. M. (2004) · Chest · doi:10.1378/chest.125.3.879 · Cited by 114
Metadata
- Authors
- Fleury, B., Rakotonanahary, D., Hausser-Hauw, C., Lebeau, B., & Guilleminault, C.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-08
- Volume
- 19
- Issue
- 6
- Pages
- 502-505
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W289207924
- Cited by
- 59
- References
- 0
- FWCI
- 2.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Laboratory Validation Study of the Diagnostic Mode of the Autoset™ System for Sleep-Related Respiratory Disorders. https://app.cochat.ai/papers/10.1093/sleep/19.6.502
- The paper
- Fleury, B., Rakotonanahary, D., Hausser-Hauw, C., Lebeau, B., & Guilleminault, C. (1996). A Laboratory Validation Study of the Diagnostic Mode of the Autoset™ System for Sleep-Related Respiratory Disorders. Sleep. https://doi.org/10.1093/sleep/19.6.502
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.