CoChat

Full Polysomnography in the Home

Fry, June M., DiPhillipo, Mark A., Curran, Kenneth, Goldberg, Rochelle, Baran, A. Sinan · 1998 · Sleep
Cited by 97

The DOI matches its Crossref record.

Abstract

STUDY OBJECTIVES: To evaluate unattended full polysomnography (PSG) recorded in the home by the DigiTrace Home Sleep System (DHSS) and to assess the ability to acquire, store and analyze polysomnographic data using the DHSS compared to standard paper PSG. DESIGN: Part 1 used a prospective, cross-over design. Part 2 consisted of a prospective concurrent collection of polysomnographic data. SETTING: Sleep Disorders Center in a university medical center. PARTICIPANTS: All adult patients who required standard clinical PSG as part of their clinical evaluation, regardless of suspected diagnosis, except patients requiring video recording for abnormal behaviors. MEASUREMENTS AND RESULTS: The DHSS is a digital recording system with miniature preamplifiers and the capacity to record 18 channels of polysomnographic data, including 4 channels of EEG (C3-A2, C4-A1, C3-O1 and C4-O2), right and left EOG, two channels of chin EMG, ECG naso-oral airflow, respiratory effort (piezo crystal thoracic and abdominal belts and bilateral interacostal EMG), snore microphone, bilateral anterior tibialis EMG, and body-position sensor. In part 1,77 DHSS home recordings were evaluated. No recordings were lost due to equipment failure and each parameter was scorable in greater than 95% of all epochs. Most of the subjective assessments by questionnaire following each study revealed no difference between the two testing situations. However, patients reported more sleep time and a better overall test experience in the lab. Assessments of sleep quality and morning alertness compared to usual were rated higher in the lab. After completing both studies, more patients preferred the lab study (p < .01), mostly because of minor inconveniences and apprehension regarding acquisition of data during the home study. There was no difference in the assessment of which test most accurately represented their sleep. In Part 2, the DHSS recorded concurrently with paper PSG in the laboratory in 16 patients. The results show no significant differences for any parameter and strong positive correlations for all parameters. CONCLUSION: Using the DHSS, unattended full PSG can be performed in the home with reliable and high quality recordings. Full PSG can be extended to a larger patient population, because it is no longer limited by the number of beds, and there is a reduction in cost due to elimination of overnight staff and facility cost.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/sleep/21.6.635

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 97

Metadata

Authors
Fry, J. M., DiPhillipo, M. A., Curran, K., Goldberg, R., & Baran, A. S.
Venue
Sleep
Published
1998-09
Volume
21
Issue
6
Pages
635-642
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W186027583
Cited by
97
References
0
FWCI
7.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Full Polysomnography in the Home. https://app.cochat.ai/papers/10.1093/sleep/21.6.635
The paper
Fry, J. M., DiPhillipo, M. A., Curran, K., Goldberg, R., & Baran, A. S. (1998). Full Polysomnography in the Home. Sleep. https://doi.org/10.1093/sleep/21.6.635

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.