Full Polysomnography in the Home
The DOI matches its Crossref record.
Abstract
STUDY OBJECTIVES: To evaluate unattended full polysomnography (PSG) recorded in the home by the DigiTrace Home Sleep System (DHSS) and to assess the ability to acquire, store and analyze polysomnographic data using the DHSS compared to standard paper PSG. DESIGN: Part 1 used a prospective, cross-over design. Part 2 consisted of a prospective concurrent collection of polysomnographic data. SETTING: Sleep Disorders Center in a university medical center. PARTICIPANTS: All adult patients who required standard clinical PSG as part of their clinical evaluation, regardless of suspected diagnosis, except patients requiring video recording for abnormal behaviors. MEASUREMENTS AND RESULTS: The DHSS is a digital recording system with miniature preamplifiers and the capacity to record 18 channels of polysomnographic data, including 4 channels of EEG (C3-A2, C4-A1, C3-O1 and C4-O2), right and left EOG, two channels of chin EMG, ECG naso-oral airflow, respiratory effort (piezo crystal thoracic and abdominal belts and bilateral interacostal EMG), snore microphone, bilateral anterior tibialis EMG, and body-position sensor. In part 1,77 DHSS home recordings were evaluated. No recordings were lost due to equipment failure and each parameter was scorable in greater than 95% of all epochs. Most of the subjective assessments by questionnaire following each study revealed no difference between the two testing situations. However, patients reported more sleep time and a better overall test experience in the lab. Assessments of sleep quality and morning alertness compared to usual were rated higher in the lab. After completing both studies, more patients preferred the lab study (p < .01), mostly because of minor inconveniences and apprehension regarding acquisition of data during the home study. There was no difference in the assessment of which test most accurately represented their sleep. In Part 2, the DHSS recorded concurrently with paper PSG in the laboratory in 16 patients. The results show no significant differences for any parameter and strong positive correlations for all parameters. CONCLUSION: Using the DHSS, unattended full PSG can be performed in the home with reliable and high quality recordings. Full PSG can be extended to a larger patient population, because it is no longer limited by the number of beds, and there is a reduction in cost due to elimination of overnight staff and facility cost.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Home Diagnosis of Sleep Apnea: A Systematic Review of the Literature
Flemons, W. W., Littner, M. R., Rowley, J. A., Gay, P., Anderson, W. M., Hudgel, D. W., McEvoy, R. D., & Loube, D. I. (2003) · Chest · doi:10.1378/chest.124.4.1543 · Cited by 571
Prevalence of Sleep-disordered Breathing in Middle-aged Korean Men and Women
Kim, J., In, K., Kim, J., You, S., Kang, K., Shim, J., Lee, S., Lee, J., Lee, S., Park, C., et al. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200404-519oc · Cited by 516
Iber, C., Redline, S., Gilpin, A. M. K., Quan, S. F., Zhang, L., Gottlieb, D. J., Rapoport, D., Resnick, H. E., Sanders, M., & Smith, P. (2004) · Sleep · doi:10.1093/sleep/27.3.536 · Cited by 195
Pittman, S. D., Ayas, N. T., MacDonald, M. M., Malhotra, A., Fogel, R. B., & White, D. P. (2004) · Sleep · doi:10.1093/sleep/27.5.923 · Cited by 175
Zou, D., Grote, L., Peker, Y., Lindblad, U., & Hedner, J. (2006) · Sleep · doi:10.1093/sleep/29.3.367 · Cited by 162
Hypertension prevalence in obstructive sleep apnoea and sex: a population-based case–control study
Hedner, J., Bengtsson-Boström, K., Peker, Y., Grote, L., Råstam, L., & Lindblad, U. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00042105 · Cited by 158
Diagnosis of Obstructive Sleep Apnea Syndrome and Its Outcomes With Home Portable Monitoring
de Oliveira, A. C. T., Martinez, D., Vasconcelos, L. F. T., Cadaval Gonçalves, S., do Carmo Lenz, M., Costa Fuchs, S., Gus, M., de Abreu-Silva, E. O., Beltrami Moreira, L., & Danni Fuchs, F. (2009) · Chest · doi:10.1378/chest.08-1859 · Cited by 129
Home sleep studies in the assessment of sleep apnea/hypopnea syndrome
Golpe, R., Jime´nez, A., & Carpizo, R. (2002) · Chest · doi:10.1378/chest.122.4.1156 · Cited by 109
CAMPBELL, A. J., & NEILL, A. M. (2011) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2010.00854.x · Cited by 94
Guidelines for sleep studies in adults-a position statement of the Australasian Sleep Association
Douglas, J. A., Chai-Coetzer, C. L., McEvoy, D., Naughton, M. T., Neill, A. M., Rochford, P., Wheatley, J., & Worsnop, C. (2017) · Sleep Medicine · doi:10.1016/j.sleep.2017.03.019 · Cited by 78
Yin, M., Miyazaki, S., & Ishikawa, K. (2006) · Otolaryngology–Head and Neck Surgery · doi:10.1016/j.otohns.2005.10.019 · Cited by 60
Planès, C., Leroy, M., Bouach Khalil, N., El Mahmoud, R., Digne, F., de Roquefeuil, F., & Raffestin, B. (2010) · Sleep and Breathing · doi:10.1007/s11325-009-0275-1 · Cited by 12
“Comparative studies of unattended home polysomnography and attended in-laboratory polysomnography found similar respiratory parameter values with the two methods [21, 22].”
MethodPatel, M. R., Alexander, T. H., & Davidson, T. M. (2007) · Operative Techniques in Otolaryngology-Head and Neck Surgery · doi:10.1016/j.otot.2007.01.005 · Cited by 8
Metadata
- Authors
- Fry, J. M., DiPhillipo, M. A., Curran, K., Goldberg, R., & Baran, A. S.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-09
- Volume
- 21
- Issue
- 6
- Pages
- 635-642
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W186027583
- Cited by
- 97
- References
- 0
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.