The DOI matches its Crossref record.
Non-Invasive Detection of Respiratory Effort-Related Arousals (RERAs) by a Nasal Cannula/Pressure Transducer System
Abstract
STUDY OBJECTIVES: The published AASM guidelines approve use of a nasal cannula/pressure transducer to detect apneas/hypopneas, but require esophageal manometry for Respiratory Effort-Related Arousals (RERAs). However, esophageal manometry may be poorly tolerated by many subjects. We have shown that the shape of the inspiratory flow signal from a nasal cannula identifies flow limitation and elevated upper-airway resistance. This study tests the hypothesis that detection of flow limitation events using the nasal cannula provides a non-invasive means to identify RERAs. DESIGN: N/A. SETTING: N/A. PATIENTS: 10 UARS/OSAS and 5 normal subjects INTERVENTIONS: N/A. MEASUREMENTS AND RESULTS: All subjects underwent full NPSG. Two scorers identified events from the nasal cannula signal as apneas, hypopneas, and flow limitation events. Two additional scorers identified events from esophageal manometry. Arousals were scored in a separate pass. Interscorer reliability and intersignal agreement were assessed both without and with regard to arousal. The total number of respiratory events identified by the two scorers of the nasal cannula was similar with an Intraclass Correlation (ICC) =0.96, and was essentially identical to the agreement for the two scorers of esophageal manometry (ICC=0.96). There was good agreement between the number of events detected by the two techniques with a slight bias towards the nasal cannula (4.5 events/hr). There was no statistically significant difference (bias 0.9/hr, 95%CI -0.3-2.0) between the number of nasal cannula flow limitation events terminated by arousal and manometry events terminated by arousal (RERAs). CONCLUSION: The nasal cannula/pressure transducer provides a non-invasive reproducible detector of all events in sleep disordered breathing; in particular, it detects the same events as esophageal manometry (RERAs).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Berry, R. B., Budhiraja, R., Gottlieb, D. J., Gozal, D., Iber, C., Kapur, V. K., Marcus, C. L., Mehra, R., Parthasarathy, S., Quan, S. F., et al. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2172 · Cited by 5,302
Malhotra, A., & White, D. P. (2002) · The Lancet · doi:10.1016/s0140-6736(02)09464-3 · Cited by 1,190
Weaver, T. E., Maislin, G., Dinges, D. F., Bloxham, T., George, C. F. P., Greenberg, H., Kader, G., Mahowald, M., Younger, J., & Pack, A. I. (2007) · Sleep · doi:10.1093/sleep/30.6.711 · Cited by 1,058
Patil, S. P., Schneider, H., Schwartz, A. R., & Smith, P. L. (2007) · Chest · doi:10.1378/chest.07-0040 · Cited by 556
Complex Sleep Apnea Syndrome: Is It a Unique Clinical Syndrome?
Morgenthaler, T. I., Kagramanov, V., Hanak, V., & Decker, P. A. (2006) · Sleep · doi:10.1093/sleep/29.9.1203 · Cited by 462
Metadata
- Authors
- Ayappa, I., Norman, R. G., Krieger, A. C., Rosen, A., O'Malley, R. L., & Rapoport, D. M.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-09
- Volume
- 23
- Issue
- 6
- Pages
- 763-771
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W149332737
- Cited by
- 230
- References
- 0
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-Invasive Detection of Respiratory Effort-Related Arousals (RERAs) by a Nasal Cannula/Pressure Transducer System. https://app.cochat.ai/papers/10.1093/sleep/23.6.763
- The paper
- Ayappa, I., Norman, R. G., Krieger, A. C., Rosen, A., O'Malley, R. L., & Rapoport, D. M. (2000). Non-Invasive Detection of Respiratory Effort-Related Arousals (RERAs) by a Nasal Cannula/Pressure Transducer System. Sleep. https://doi.org/10.1093/sleep/23.6.763
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.