Validation of a Suprasternal Pressure Transducer for Apnea Classification During Sleep
The DOI matches its Crossref record.
Abstract
STUDY OBJECTIVES: To validate a new method of evaluation of respiratory efforts during polysomnographic recordings. SETTING: NA PARTICIPANTS: 26 patients with sleep apnea syndrome, either during diagnostic assessment (n=16) or under nasal continuous positive airway pressure (n=10). METHODS: This method consists of measuring suprastemal pressure by a pressure transducer placed over the trachea above the sternal notch (Pst). It was compared to the reference method (ie, esophageal pressure) during the same polysomnogram. RESULTS: The analysis was based on 3,261 episodes of apnea, classified as obstructive in 2,556 cases, mixed in 347 cases, and central in 358 cases according to the esophageal pressure monitor. The concordance between the two methods was very good, with a sensitivity of Pst of 99.4% for the detection of apneas with respiratory efforts and a specificity of 93.6%. Twenty-three (6.4%) of the 358 central apneas were classified by Pst as apneas with respiratory efforts and 18 of the 353 central apneas classified by Pst were actually apneas with respiratory efforts on the esophageal pressure monitor. CONCLUSION: The suprasternal pressure transducer, which presents a good sensitivity and a good specificity for identification of respiratory efforts, can be used to classify apneas during polysomnographic recordings in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Scoring of Respiratory Events in Sleep: Reliability and Validity
Redline, S., Budhiraja, R., Kapur, V., Marcus, C. L., Mateika, J. H., Mehra, R., Parthasarthy, S., Somers, V. K., Strohl, K. P., Gozal, D., et al. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26818 · Cited by 305
A combined neuropsychological and brain imaging study of obstructive sleep apnea
YAOUHI, K., BERTRAN, F., CLOCHON, P., MÉZENGE, F., DENISE, P., FORET, J., EUSTACHE, F., & DESGRANGES, B. (2009) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2008.00705.x · Cited by 238
“The occurrence of respiratory efforts was validated by means of a suprasternal pressure transducer (Meslier et al., 2002).”
MethodChronically implanted pressure sensors: challenges and state of the field
Yu, L., Kim, B., & Meng, E. (2014) · Sensors · doi:10.3390/s141120620 · Cited by 200
“Current methods utilize measurements of stomach distension or suprasternal placement of strain sensors [109] to infer pressures within the thoracic cavity, but these noninvasive approaches lack accuracy and specificity, limiting clinical use.”
MethodNguyên, X.-L., Chaskalovic, J., Rakotonanahary, D., & Fleury, B. (2010) · Sleep Medicine · doi:10.1016/j.sleep.2010.04.008 · Cited by 69
“The portable monitor (CID 102, CIDELEC, Gemmes sur Loire, France) analyzes snoring, oxyhaemoglobin saturation, nasal airflow by a nasal cannula and monitors respiratory effort with thoracic and abdominal strain gauges and a substernal pressure captor [19].”
Planès, C., Leroy, M., Bouach Khalil, N., El Mahmoud, R., Digne, F., de Roquefeuil, F., & Raffestin, B. (2010) · Sleep and Breathing · doi:10.1007/s11325-009-0275-1 · Cited by 12
“The simplified automated device, CID102L8, may be well-suited to the diagnosis of OSA in coronary patients since it differentiates between obstructive and central apnoea [28].”
Method
Metadata
- Authors
- Meslier, N., Simon, I., Kouatchet, A., Ouksel, H., Person, C., & -Louis Racineux, J.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-10
- Volume
- 25
- Issue
- 7
- Pages
- 753-757
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W2405756845
- Cited by
- 39
- References
- 0
- FWCI
- 0.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of a Suprasternal Pressure Transducer for Apnea Classification During Sleep. https://app.cochat.ai/papers/10.1093/sleep/25.7.753
- The paper
- Meslier, N., Simon, I., Kouatchet, A., Ouksel, H., Person, C., & -Louis Racineux, J. (2002). Validation of a Suprasternal Pressure Transducer for Apnea Classification During Sleep. Sleep. https://doi.org/10.1093/sleep/25.7.753
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.