Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 201

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Self-Efficacy in Sleep Apnea: Instrument Development and Patient Perceptions of Obstructive Sleep Apnea Risk, Treatment Benefit, and Volition to Use Continuous Positive Airway Pressure

Weaver, Terri E., Maislin, Greg, Dinges, David F., Younger, Joel, Cantor, Charles, McCloskey, Susan, Pack, Allan I.·2003·Sleep

Abstract

STUDY OBJECTIVES: The purpose of this study was to evaluate the Self-Efficacy Measure for Sleep Apnea (SEMSA) designed to assess adherence-related cognitions. DESIGN: Subjects completed the questionnaire prior to the initiation of continuous positive airway pressure (CPAP) treatment. Test-retest reliability of the instrument was evaluated by having a subset of subjects complete the SEMSA a second time at home, 1 week later, returning the questionnaire by mail. PATIENTS: 213 subjects with newly diagnosed obstructive sleep apnea were recruited from the clinic populations of 2 sleep disorders centers. MEASUREMENTS AND RESULTS: Content validity was confirmed by a panel of expert judges. Confirmatory factor analysis validated the 3 a priori sub-scales: risk perception, outcome expectancies, and treatment self-efficacy. The internal consistency of the total instrument was 0.92. Test-retest reliability coefficients (N = 20) were estimated to be 0.68, P = 0.001, for Perceived Risk; 0.77, P more more than 0.0001, for Outcome Expectancies; and 0.71, P = 0.0005, for the Treatment Self-Efficacy subscale. Subject responses indicated that approximately half of the subjects did not perceive problems with concentration, sexual performance, sleepy driving, or an accident as related to sleep apnea. More than 60% of the subjects acknowledged most of the benefits of CPAP presented to them, but only 53% associated CPAP use with enhanced sexual performance. Frequently identified barriers to treatment use were nasal stuffiness, claustrophobia, and disturbing bed partner sleep. CONCLUSION: These findings indicate that the SEMSA has strong psychometric properties and has the potential for identifying patient perceptions that may indicate those most likely to not adhere to treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/sleep/26.6.727

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 201

Metadata

Authors
Weaver, T. E., Maislin, G., Dinges, D. F., Younger, J., Cantor, C., McCloskey, S., & Pack, A. I.
Venue
Sleep
Published
2003-09-01
Volume
26
Issue
6
Pages
727-732
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W2113602769
Cited by
201
References
6
FWCI
1.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Self-Efficacy in Sleep Apnea: Instrument Development and Patient Perceptions of Obstructive Sleep Apnea Risk, Treatment Benefit, and Volition to Use Continuous Positive Airway Pressure. https://app.cochat.ai/papers/10.1093/sleep/26.6.727
The paper
Weaver, T. E., Maislin, G., Dinges, D. F., Younger, J., Cantor, C., McCloskey, S., & Pack, A. I. (2003). Self-Efficacy in Sleep Apnea: Instrument Development and Patient Perceptions of Obstructive Sleep Apnea Risk, Treatment Benefit, and Volition to Use Continuous Positive Airway Pressure. Sleep. https://doi.org/10.1093/sleep/26.6.727

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.