The DOI matches its Crossref record; 164 of the 164 references it cites were found in a registry or an index.
Educational, supportive and behavioural interventions to improve usage of continuous positive airway pressure machines in adults with obstructive sleep apnoea
Open accessAbstract
BACKGROUND: Although effective in the treatment of obstructive sleep apnoea (OSA), continuous positive airway pressure (CPAP) is not universally accepted by users. Educational, supportive and behavioural interventions may help people with OSA recognise the need for regular and continued use of CPAP. OBJECTIVES: To assess the effectiveness of strategies that are educational, supportive or behavioural in encouraging people who have been prescribed CPAP to use their machines. SEARCH METHODS: Searches were conducted on the Cochrane Airways Group Specialised Register of trials. Searches are current to 17 January 2013. SELECTION CRITERIA: We included randomised parallel controlled trials that assessed an intervention designed to inform participants about CPAP or OSA, to support them in using CPAP or to modify their behaviour in increasing their use of CPAP machines. Studies of any duration were considered. DATA COLLECTION AND ANALYSIS: Two review authors assessed studies to determine their suitability for inclusion in the review. Data were extracted independently and were entered into Review Manager software for analysis. MAIN RESULTS: Thirty studies (2047 participants) were included. We categorised studies by intervention type: supportive interventions during follow-up, educational interventions and behavioural therapy. Across all three intervention classes, most studies incorporated elements of more than one intervention. For the purposes of this systematic review, we categorised them by the prevailing type of intervention, which we expected would have the greatest impact on the study outcome.Baseline Epworth Sleepiness Scale (ESS) scores indicated that most participants experienced daytime sleepiness, and CPAP was indicated on the basis of sleep disturbance indices. A vast majority of recruited participants had not used CPAP previously. Most of the studies were at an unclear risk of bias overall, although because of the nature of the intervention, blinding of both study personnel and participants was not feasible, and this affected a number of key outcomes. Adverse events were not reported in these studies.Low- to moderate-quality evidence showed that all three types of interventions led to increased machine usage in CPAP-naive participants with moderate to severe OSA syndrome. Compared with usual care, supportive ongoing interventions increased machine usage by about 50 minutes per night (0.82 hours, 95% confidence interval (CI) 0.36 to 1.27, N = 803, 13 studies; low-quality evidence), increased the number of participants who used their machines for longer than four hours per night from 59 to 75 per 100 (odds ratio (OR) 2.06, 95% CI 1.22 to 3.47, N = 268, four studies; low-quality evidence) and reduced the likelihood of study withdrawal (OR 0.65, 95% CI 0.44 to 0.97, N = 903, 12 studies; moderate-quality evidence). With the exception of study withdrawal, considerable variation was evident between the results of individual studies across these outcomes. Evidence of an effect on symptoms and quality of life was statistically imprecise (ESS score -0.60 points, 95% CI -1.81 to 0.62, N = 501, eight studies; very low-quality evidence; Functional Outcomes of Sleep Questionnaire 0.98 units, 95% CI -0.84 to 2.79, N = 70, two studies; low-quality evidence, respectively).Educational interventions increased machine usage by about 35 minutes per night (0.60 hours, 95% CI 0.27 to 0.93, N = 508, seven studies; moderate-quality evidence), increased the number of participants who used their machines for longer than four hours per night from 57 to 70 per 100 (OR 1.80, 95% CI 1.09 to 2.95, N = 285, three studies; low-quality evidence) and reduced the likelihood of withdrawal from the study (OR 0.67, 95% CI 0.45 to 0.98, N = 683, eight studies; low-quality evidence). Participants experienced a small improvement in symptoms, the size of which may not be clinically significant (ESS score -1.17 points, 95% CI -2.07 to -0.26, N = 336, five studies).Behavioural therapy led to substantial improvement in average machine usage of 1.44 hours per night (95% CI 0.43 to 2.45, N = 584, six studies; low-quality evidence) and increased the number of participants who used their machines for longer than four hours per night from 28 to 47 per 100 (OR 2.23, 95% CI 1.45 to 3.45, N = 358, three studies; low-quality evidence) but with high levels of statistical heterogeneity. The estimated lower rate of withdrawal with behavioural interventions was imprecise and did not reach statistical significance (OR 0.85, 95% CI 0.57 to 1.25, N = 609, five studies, very low-quality evidence). AUTHORS' CONCLUSIONS: In CPAP-naive people with severe sleep apnoea, low-quality evidence indicates that supportive interventions that encourage people to continue to use their CPAP machines increase usage compared with usual care. Moderate-quality evidence shows that a short-term educational intervention results in a modest increase in CPAP usage. Low-quality evidence indi
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Cochrane Handbook for Systematic Reviews of Interventions: Cochrane Book Series
(2008) · doi:10.1002/9780470712184 · Cited by 25,048
Self-efficacy mechanism in human agency
Bandura, A. (1982) · American Psychologist · doi:10.1037/0003-066x.37.2.122 · Cited by 15,975
Pharmacological interventions for somatoform disorders in adults
Kleinstäuber, M., Witthöft, M., Steffanowski, A., van Marwijk, H., Hiller, W., & Lambert, M. J. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010628.pub2 · Cited by 11,335
Stages and processes of self-change of smoking: Toward an integrative model of change.
Prochaska, J. O., & DiClemente, C. C. (1983) · Journal of Consulting and Clinical Psychology · doi:10.1037/0022-006x.51.3.390 · Cited by 9,098
Health Promotion by Social Cognitive Means
Bandura, A. (2004) · Health Education & Behavior · doi:10.1177/1090198104263660 · Cited by 7,238
Cochrane Handbook for Systematic Reviews of Interventions Version 5.0.1. The Cochrane Collaboration
Higgins, J., Green, S. R., & Higgins, J. (2008) · Cited by 5,544
Prospective Study of the Association between Sleep-Disordered Breathing and Hypertension
Peppard, P. E., Young, T., Palta, M., & Skatrud, J. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005113421901 · Cited by 4,973
Marin, J. M., Carrizo, S. J., Vicente, E., & Agusti, A. G. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71141-7 · Cited by 4,678
Epidemiology of Obstructive Sleep Apnea: A Population Health Perspective
Young, T., Peppard, P. E., & Gottlieb, D. J. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2109080 · Cited by 4,244
Cited by
Meschia, J. F., Bushnell, C., Boden-Albala, B., Braun, L. T., Bravata, D. M., Chaturvedi, S., Creager, M. A., Eckel, R. H., Elkind, M. S. V., Fornage, M., et al. (2014) · Stroke · doi:10.1161/str.0000000000000046 · Cited by 2,650
Diagnosis and Management of Obstructive Sleep Apnea: A Review
Gottlieb, D. J., & Punjabi, N. M. (2020) · JAMA · doi:10.1001/jama.2020.3514 · Cited by 1,482
Trends in CPAP adherence over twenty years of data collection: A flattened curve
Rotenberg, B. W., Murariu, D., & Pang, K. P. (2016) · Journal of Otolaryngology - Head & Neck Surgery · doi:10.1186/s40463-016-0156-0 · Cited by 742
Pathophysiological mechanisms and therapeutic approaches in obstructive sleep apnea syndrome
Lv, R., Liu, X., Zhang, Y., Dong, N., Wang, X., He, Y., Yue, H., & Yin, Q. (2023) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-023-01496-3 · Cited by 477
Tietjens, J. R., Claman, D., Kezirian, E. J., De Marco, T., Mirzayan, A., Sadroonri, B., Goldberg, A. N., Long, C., Gerstenfeld, E. P., & Yeghiazarians, Y. (2019) · Journal of the American Heart Association · doi:10.1161/jaha.118.010440 · Cited by 397
Metadata
- Authors
- Wozniak, D. R., Lasserson, T. J., & Smith, I.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2014-01-08
- Volume
- 4
- Issue
- 1
- Pages
- CD007736-CD007736
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W2105795440
- Cited by
- 379
- References
- 164
- FWCI
- 24.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Educational, supportive and behavioural interventions to improve usage of continuous positive airway pressure machines in adults with obstructive sleep apnoea. https://app.cochat.ai/papers/10.1002/14651858.cd007736.pub2
- The paper
- Wozniak, D. R., Lasserson, T. J., & Smith, I. (2014). Educational, supportive and behavioural interventions to improve usage of continuous positive airway pressure machines in adults with obstructive sleep apnoea. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd007736.pub2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.