CoChat

Validation of a New System of Tracheal Sound Analysis for the Diagnosis of Sleep Apnea-Hypopnea Syndrome

Open access
Nakano, Hiroshi, Hayashi, Makito, Ohshima, Etsuko, Nishikata, Nahoko, Shinohara, Toshimitsu · 2004 · Sleep
Cited by 103

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

STUDY OBJECTIVES: To evaluate the validity of a novel method of using tracheal sound analysis for the diagnosis of sleep apnea-hypopnea syndrome. DESIGN: Retrospective analysis in consecutive patients. SETTING: A sleep clinic in a general hospital. PATIENTS: A total of 383 patients who were referred for suspected sleep apnea-hypopnea syndrome and underwent diagnostic polysomnography with sufficient quality. INTERVENTIONS: N/A. MEASUREMENTS AND RESULTS: Ordinary polysomnography with simultaneous tracheal sound recording was performed. The apnea-hypopnea index (AHI) was calculated as the number of apnea and hypopnea events per hour of sleep. Tracheal sounds were digitized and recorded as power spectra. An automated computer program detected transient falls (TS-dip) in the time series of moving average of the logarithmic power of tracheal sound. We defined the tracheal sound-respiratory disturbance index (TS-RDI) as the number of TS-dips per hour of examination. We also calculated the oxygen desaturation index (the number of SaO2 dips of at least 4% per hour of examination). The TS-RDI highly correlated with AHI (r = 0.93). The mean (+/- SD) difference between the TS-RDI and AHI was -8.4 +/- 10.4. The diagnostic sensitivity and specificity of the TS-RDI when the same cutoff value was used as for AHI were 93% and 67% for the AHI cutoff value of 5 and 79% and 95% for the AHI cutoff value of 15. The agreement between the TS-RDI and AHI was better than that between the oxygen desaturation index and AHI. CONCLUSIONS: The fully automated tracheal sound analysis demonstrated a relatively high performance in the diagnosis of sleep apnea-hypopnea syndrome. We think that this method is useful for the portable monitoring of sleep apnea-hypopnea syndrome.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/sleep/27.5.951

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 103

Metadata

Authors
Nakano, H., Hayashi, M., Ohshima, E., Nishikata, N., & Shinohara, T.
Venue
Sleep
Published
2004-08
Volume
27
Issue
5
Pages
951-957
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W36564834
Cited by
103
References
3
FWCI
1.33
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of a New System of Tracheal Sound Analysis for the Diagnosis of Sleep Apnea-Hypopnea Syndrome. https://app.cochat.ai/papers/10.1093/sleep/27.5.951
The paper
Nakano, H., Hayashi, M., Ohshima, E., Nishikata, N., & Shinohara, T. (2004). Validation of a New System of Tracheal Sound Analysis for the Diagnosis of Sleep Apnea-Hypopnea Syndrome. Sleep. https://doi.org/10.1093/sleep/27.5.951

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.