The Effect of Measurement Unreliability on Sleep and Respiratory Variables
The DOI matches its Crossref record.
Abstract
INTRODUCTION: Unreliability associated with scoring sleep variables is a potentially problematic issue in clinical and research studies. When scoring unreliability is unrecognized, it can contribute to the following: increase variability in the measures of interest, decrease a study's ability to detect important relationships, attenuate correlation coefficients, and increase clinical trial costs. METHODS: This paper first models the relationship between scoring variability and reliability in commonly studied sleep variables. The paper then models the relationship between unreliability and sample size requirements and statistical power. Standard methods are used to model reliability using the intraclass correlation coefficient. RESULTS: The analysis shows that when scoring unreliability is minimized (i.e., scoring reliability is maximized), correlation coefficients are more robust, sample size requirements are reduced, statistical power is increased, and clinical trial costs are reduced. DISCUSSION: When scoring unreliability is recognized, research studies can compensate by increasing the number of research subjects studied; however, it is at the cost of increasing the costs of research and exposing greater numbers of subjects to possible study risks. An effective solution is to implement rigorous initial and ongoing training efforts to maintain high inter-rater and intra-rater reliability coefficients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The new AASM criteria for scoring hypopneas: impact on the apnea hypopnea index
Ruehland, W. R., Rochford, P. D., O’Donoghue, F. J., Pierce, R. J., Singh, P., & Thornton, A. T. (2009) · SLEEP · doi:10.1093/sleep/32.2.150 · Cited by 696
The Visual Scoring of Sleep and Arousal in Infants and Children
Grigg-Damberger, M., Gozal, D., Marcus, C. L., Quan, S. F., Rosen, C. L., Chervin, R. D., Wise, M., Picchietti, D. L., Sheldon, S. H., & Iber, C. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26819 · Cited by 361
A review of signals used in sleep analysis
Roebuck, A., Monasterio, V, Gederi, E., Osipov, M., Behar, J., Malhotra, A., Penzel, T., & Clifford, G. D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/1/r1 · Cited by 223
“Inter-rater reliability/agreement has been shown to vary between 0.6 and 0.9 (using Cohen’s κ value14 (Crowell et al 1997, Stepnowsky et al 2004, Ferri et al 2005, Rosa et al 2006).”
MethodInfluentialData Quality in Clinical Research
Nahm, M. (2012) · Health Informatics · doi:10.1007/978-1-84882-448-5_10 · Cited by 32
Garza, M. Y., Williams, T., Ounpraseuth, S., Hu, Z., Lee, J., Snowden, J., Walden, A. C., Simon, A. E., Devlin, L. A., Young, L. W., et al. (2025) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2024.105749 · Cited by 17
Metadata
- Authors
- Stepnowsky, C. J., Berry, C., & Dimsdale, J. E.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-08
- Volume
- 27
- Issue
- 5
- Pages
- 990-995
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W105407044
- Cited by
- 31
- References
- 0
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.