Abstract

STUDY OBJECTIVES: Evaluate the utility of overnight monitoring limited to nasal cannula airflow and oximetry in the diagnosis of obstructive sleep apnea-hypopnea syndrome (OSAHS). DESIGN: Prospective randomized study, blinded analysis. SETTING: Sleep disorder center, academic institution. PARTICIPANTS: 56 patients with suspected OSAHS, 10 normal volunteers. MEASUREMENTS AND RESULTS: In-laboratory full nocturnal polysomnography (NPSG) and unattended ambulatory study with monitoring of only airflow and oximetry performed in randomized order. Obstructive respiratory events were scored on the full NPSG while visualizing all signals and then rescored on the full NPSG and on the ambulatory study while visualizing only airflow and oximetry signals. Respiratory disturbance indexes (RDI) for the limited studies (RDIFlowNPSG and RDIFlowAmbulatory) were calculated as the sum of the apneas and hypopneas (defined using airflow amplitude and O2 desaturation) divided by the valid flow-signal time. The reference RDIFullNPSG was calculated from the sum of the apneas and hypopneas (defined using flow amplitude, O2 desaturation and electroencephalographic arousal) identified on the full NPSG divided by the total sleep time. RDIFullNPSG was greater than RDIFlowNPSG (bias = 5.6 events per hour) and RDIFlowAmbulatory (bias = 10.9 events per hour), but the differences were mainly in subjects with an RDI > 40 events per hour. The diagnostic sensitivity and specificity for the diagnosis of OSAHS using a cutoff of 18 events per hour were 96% and 93% using the flow signal from the NPSG and 88% and 92% using the flow signal from the ambulatory study performed on a separate night. CONCLUSIONS: In subjects with OSAHS, analysis of the flow signal from a nasal cannula can provide an RDI similar to that obtained in a full NPSG.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/sleep/27.6.1171

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 42

Metadata

Authors
Ayappa, I., Norman, R. G., Suryadevara, M., & Rapoport, D. M.
Venue
Sleep
Published
2004-09
Volume
27
Issue
6
Pages
1171-1179
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W61612457
Cited by
42
References
0
FWCI
1.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Limited Monitoring Using a Nasal-Cannula Flow Signal to Full Polysomnography in Sleep-Disordered Breathing. https://app.cochat.ai/papers/10.1093/sleep/27.6.1171
The paper
Ayappa, I., Norman, R. G., Suryadevara, M., & Rapoport, D. M. (2004). Comparison of Limited Monitoring Using a Nasal-Cannula Flow Signal to Full Polysomnography in Sleep-Disordered Breathing. Sleep. https://doi.org/10.1093/sleep/27.6.1171

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.