Assessment of Automated Scoring of Polysomnographic Recordings in a Population with Suspected Sleep-disordered Breathing
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
STUDY OBJECTIVES: To assess the accuracy of an automated system (Morpheus I Sleep Scoring System) for analyzing and quantifying polysomnographic data from a population with sleep-disordered breathing. SETTING: Sleep laboratory affiliated with a tertiary care academic medical center. MEASUREMENTS AND RESULTS: 31 diagnostic polysomnograms were blindly analyzed prospectively with the investigational automated system and manually by 2 registered polysomnography technologists (M1 & M2) from the same laboratory. Sleep stages, arousals, periodic limb movements, and respiratory events (apneas and hypopneas) were scored by all 3. Agreement, Cohen kappa, and intraclass correlation coefficients were tabulated for each variable and compared between scoring pairs (A-M1, A-M2, M1-M2). The 26,876 epochs (224 hours of recording time) were analyzed. For sleep staging, agreement/kappa were A-M1: 78%/0.67, A-M2: 73%/0.61, and M1-M2: 82%/0.73. The mean respiratory disturbance indexes were M1: 20.6+/-23.0, M2: 22.5+/-24.5, and A: 23.7+/-23.4 events per hour of sleep. The respiratory disturbance index concordance between each scoring pair was excellent (intraclass correlation coefficients > or = 0.95 for all pairs), although there was disagreement in the classification of moderate sleep-disordered breathing (percentage of positive agreement: A-M1, 37.5% and A-M2, 44.4%) defined as a respiratory disturbance index between 15 and 30 events per hour of sleep. For respiratory-event detection, agreement/kappa were A-M1 and A-M2: 90%/0.66 and M1-M2: 95%/0.82. The agreement and kappa for limb movement detection were A-M1: 93%/0.68, A-M2: 92%/0.66, and M1-M2: 96%/0.77. The scoring of arousals was less reliable (agreement range: 76%-84%, kappa range: 0.28-0.57) for all pairs. CONCLUSIONS: Agreement between manual scorers in a population with moderate sleep-disordered breathing was close to the average pairwise agreement of 87% reported in the Sleep Heart Health Study. The automated classification of sleep stages was also close to this standard. The automated scoring system holds promise as a rapid method to score polysomnographic records, but expert verification of the automated scoring is required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Reliability of Scoring Respiratory Disturbance Indices and Sleep Staging
Whitney, C. W., Gottlieb, D. J., Redline, S., Norman, R. G., Dodge, R. R., Shahar, E., Surovec, S., & Nieto, F. J. (1998) · Sleep · doi:10.1093/sleep/21.7.749 · Cited by 327 · cited 1×
“The information gathered from the EEG, EOG, and EMG signals is fused by the Rechtschaffen and Kales criteria for automatic sleep staging, in the following manner: (1) the membership level in the high-frequency state and detected movements are used for scoring stage wake; (2) the membership level in the low-energy mixe…”
Method
Cited by
Mulgrew, A. T., Fox, N., Ayas, N. T., & Ryan, C. F. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-3-200702060-00004 · Cited by 368
Automatic Analysis of Single-Channel Sleep EEG: Validation in Healthy Individuals
Berthomier, C., Drouot, X., Herman-Stoïca, M., Berthomier, P., Prado, J., Bokar-Thire, D., Benoit, O., Mattout, J., & d'Ortho, M.-P. (2007) · Sleep · doi:10.1093/sleep/30.11.1587 · Cited by 294
Automated sleep scoring: A review of the latest approaches
Fiorillo, L., Puiatti, A., Papandrea, M., Ratti, P.-L., Favaro, P., Roth, C., Bargiotas, P., Bassetti, C. L., & Faraci, F. D. (2019) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2019.07.007 · Cited by 284
Anderer, P., Gruber, G., Parapatics, S., Woertz, M., Miazhynskaia, T., Klösch, G., Saletu, B., Zeitlhofer, J., Barbanoj, M. J., Danker-Hopfe, H., et al. (2005) · Neuropsychobiology · doi:10.1159/000085205 · Cited by 284
Performance of an Automated Polysomnography Scoring System Versus Computer-Assisted Manual Scoring
Malhotra, A., Younes, M., Kuna, S. T., Benca, R., Kushida, C. A., Walsh, J., Hanlon, A., Staley, B., Pack, A. I., & Pien, G. W. (2013) · Sleep · doi:10.5665/sleep.2548 · Cited by 222
Self-citation
Metadata
- Authors
- Pittman, S. D., MacDonald, M. M., Fogel, R. B., Malhotra, A., Todros, K., Levy, B., Geva, A. B., & White, D. P.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-10
- Volume
- 27
- Issue
- 7
- Pages
- 1394-1403
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W109729959
- Cited by
- 88
- References
- 3
- FWCI
- 1.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.