CoChat

Evaluation of Sham-CPAP as a Placebo in CPAP Intervention Studies

Open access
Rodway, George W., Weaver, Terri E., Mancini, Cristina, Cater, Jacqueline, Maislin, Greg, Staley, Bethany, Ferguson, Kathleen A., George, Charles F. P, Schulman, David A., Greenberg, Harly, Rapoport, David M., Walsleben, Joyce A., Lee-Chiong, Teofilo, Kuna, Samuel T. · 2010 · Sleep
Cited by 55

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

STUDY OBJECTIVES: To evaluate the use of sham-continuous positive airway pressure (CPAP) treatment as a placebo intervention. DESIGN AND SETTING: Analysis of polysomnograms performed in fixed order without sham-CPAP and on the first night of the sham-CPAP intervention in participants in the CPAP Apnea Trial North American Program (CATNAP), a randomized, placebo controlled trial evaluating the effects of CPAP treatment on daytime function in adults with newly diagnosed mild to moderate obstructive sleep apnea (apnea hypopnea index (AHI) 5-30). PARTICIPANTS: The first 104 CATNAP participants randomized to the sham-CPAP intervention arm. MEASUREMENTS AND RESULTS: Compared to the polysomnographic measures without sham-CPAP, the study on the first night with sham-CPAP had statistically significant differences that suggested a decrease in sleep quality: decreased sleep efficiency, increased arousal index, increased time in stage 1 NREM sleep, and prolonged latency to REM sleep. However, all of these differences had a relatively small effect size. Compared to the polysomnogram without sham-CPAP, the number of hypopneas on the sham-CPAP polysomnogram was significantly increased and the number of apneas significantly decreased. Relatively minor differences in AHI with and without sham-CPAP were present and were dependent on the criteria used to score hypopneas. CONCLUSION: Comparison of polysomnograms with and without sham-CPAP revealed differences that, although statistically significant, were small in magnitude and had relatively low effect sizes suggesting minimal clinical significance. The results support the use of sham-CPAP as a placebo intervention in trials evaluating the effects of CPAP treatment in patients with obstructive sleep apnea. CLINICAL TRIAL INFORMATION: This paper was a secondary analysis of clinical trial data. CATNAP: CPAP Apnea Trial North American Program, the trial from which the data were obtained, is registered with clinicaltrial.gov. Registration #NCT00089752.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/sleep/33.2.260

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 55

Metadata

Authors
Rodway, G. W., Weaver, T. E., Mancini, C., Cater, J., Maislin, G., Staley, B., Ferguson, K. A., George, C. F. P., Schulman, D. A., Greenberg, H., Rapoport, D. M., Walsleben, J. A., Lee-Chiong, T., & Kuna, S. T.
Venue
Sleep
Published
2010-02
Volume
33
Issue
2
Pages
260-266
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W1627167252
Cited by
55
References
7
FWCI
3.04
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Sham-CPAP as a Placebo in CPAP Intervention Studies. https://app.cochat.ai/papers/10.1093/sleep/33.2.260
The paper
Rodway, G. W., Weaver, T. E., Mancini, C., Cater, J., Maislin, G., Staley, B., Ferguson, K. A., George, C. F. P., Schulman, D. A., Greenberg, H., Rapoport, D. M., Walsleben, J. A., Lee-Chiong, T., & Kuna, S. T. (2010). Evaluation of Sham-CPAP as a Placebo in CPAP Intervention Studies. Sleep. https://doi.org/10.1093/sleep/33.2.260

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.