Continuous positive airway pressure as treatment for systemic hypertension in people with obstructive sleep apnoea: randomised controlled trial
Open accessAbstract
OBJECTIVE: To assess the effect of continuous positive airway pressure (CPAP) on 24 hour ambulatory blood pressure monitoring values in a large number of patients with untreated systemic hypertension of new onset and obstructive sleep apnoea. DESIGN: Multicentre, double blind, randomised, placebo controlled trial. SETTING: Eleven general hospitals in Spain between 2004 and 2007. PARTICIPANTS: 340 patients recently diagnosed as having systemic hypertension by a general practitioner (systolic blood pressure ≥140 mm Hg, diastolic blood pressure ≥90 mm Hg, or both) and an apnoea-hypopnoea index per hour of sleep of >15 events/hour. INTERVENTION: Patients were assigned to CPAP (n=169) or sham CPAP (n=171) for three months. Main outcome measurements Net changes in the different 24 hour ambulatory blood pressure monitoring values from baseline to three months of optimal or sham CPAP. RESULTS: 277 (81%) of the 340 patients randomised were men; the patients had a mean age of 52.4 (SD 10.5) years, a body mass index of 31.9 (5.7), an Epworth sleepiness scale score of 10.1 (4.3), an apnoea-hypopnoea index of 43.5 (24.5). No differences between groups were seen at baseline. Compared with placebo and analysed by intention to treat, the mean 24 hour ambulatory blood pressure of the CPAP group decreased by 1.5 (95% confidence interval: 0.4 to 2.7) mm Hg (P=0.01). The mean 24 hour ambulatory blood pressure monitoring measures decreased by 2.1 mm Hg (0.4 to 3.7) mm Hg (P=0.01) for systolic pressure and 1.3 (0.2 to 2.3) mm Hg (P=0.02) for diastolic blood pressure. Mean nocturnal blood pressure decreased by 2.1 (0.5 to 3.6) mm Hg (P=0.01). CONCLUSIONS: CPAP produced a statistically significant reduction in blood pressure in patients with systemic hypertension and obstructive sleep apnoea. This reduction is small and did not achieve the 3 mm Hg drop in mean 24 hour ambulatory blood pressure that the trial was powered to detect. Consequently, these results may have uncertain clinical relevance. However, taking into account the prevalence of hypertension and the likelihood of comorbidities, the decrease in blood pressure, although minimal, may be beneficial. TRIAL REGISTRATION: Clinical trials NCT00202527.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chobanian, A. V. (2003) · JAMA · doi:10.1001/jama.289.19.2560 · Cited by 25,386
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,655
Chobanian, A. V., Bakris, G. L., Black, H. R., Cushman, W. C., Green, L. A., Izzo, J. L., Jones, D. W., Materson, B. J., Oparil, S., Wright, J. T., et al. (2003) · Hypertension · doi:10.1161/01.hyp.0000107251.49515.c2 · Cited by 13,271
Mancia, G., De Backer, G., Dominiczak, A., Cifkova, R., Fagard, R., Germano, G., Grassi, G., Heagerty, A. M., Kjeldsen, S. E., Laurent, S., et al. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3281fc975a · Cited by 5,824
Prospective Study of the Association between Sleep-Disordered Breathing and Hypertension
Peppard, P. E., Young, T., Palta, M., & Skatrud, J. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005113421901 · Cited by 4,973
Marin, J. M., Carrizo, S. J., Vicente, E., & Agusti, A. G. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71141-7 · Cited by 4,678
Self-citationNieto, F. J. (2000) · JAMA · doi:10.1001/jama.283.14.1829 · Cited by 3,369
A Multiple Testing Procedure for Clinical Trials
O'Brien, P. C., & Fleming, T. R. (1979) · Biometrics · doi:10.2307/2530245 · Cited by 3,311
Obstructive Sleep Apnea as a Risk Factor for Stroke and Death
Yaggi, H. K., Concato, J., Kernan, W. N., Lichtman, J. H., Brass, L. M., & Mohsenin, V. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043104 · Cited by 3,004
Cited by
Barbé, F., Durán-Cantolla, J., Sánchez-de-la-Torre, M., Martínez-Alonso, M., Carmona, C., Barceló, A., Chiner, E., Masa, J. F., Gonzalez, M., Marín, J. M., et al. (2012) · JAMA · doi:10.1001/jama.2012.4366 · Cited by 792
Self-citationPeker, Y., Glantz, H., Eulenburg, C., Wegscheider, K., Herlitz, J., & Thunström, E. (2016) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201601-0088oc · Cited by 756
Trends in CPAP adherence over twenty years of data collection: A flattened curve
Rotenberg, B. W., Murariu, D., & Pang, K. P. (2016) · Journal of Otolaryngology - Head & Neck Surgery · doi:10.1186/s40463-016-0156-0 · Cited by 742
Patil, S. P., Ayappa, I. A., Caples, S. M., Kimoff, R. J., Patel, S. R., & Harrod, C. G. (2019) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7638 · Cited by 721
Martínez-García, M.-A., Capote, F., Campos-Rodríguez, F., Lloberes, P., Díaz de Atauri, M. J., Somoza, M., Masa, J. F., González, M., Sacristán, L., Barbé, F., et al. (2013) · JAMA · doi:10.1001/jama.2013.281250 · Cited by 685
Self-citation
Metadata
- Authors
- Duran-Cantolla, J., Aizpuru, F., Montserrat, J. M., Ballester, E., Teran-Santos, J., Aguirregomoscorta, J. I., Gonzalez, M., Lloberes, P., Masa, J. F., De La Pena, M., Carrizo, S., Mayos, M., Barbe, F., & Spanish Sleep and Breathing Group
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 2010-11-24
- Volume
- 341
- Issue
- nov24 1
- Pages
- c5991-c5991
- ISSN
- 0007-1447 (ISSN-L)
- 0959-8138
- 1468-5833
- OpenAlex
- W2128416574
- Cited by
- 257
- References
- 58
- FWCI
- 11.41
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous positive airway pressure as treatment for systemic hypertension in people with obstructive sleep apnoea: randomised controlled trial. https://app.cochat.ai/papers/10.1136/bmj.c5991
- The paper
- Duran-Cantolla, J., Aizpuru, F., Montserrat, J. M., Ballester, E., Teran-Santos, J., Aguirregomoscorta, J. I., Gonzalez, M., Lloberes, P., Masa, J. F., De La Pena, M., Carrizo, S., Mayos, M., Barbe, F., & Spanish Sleep and Breathing Group. (2010). Continuous positive airway pressure as treatment for systemic hypertension in people with obstructive sleep apnoea: randomised controlled trial. BMJ. https://doi.org/10.1136/bmj.c5991
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.