RATIONALE: The most common single channel devices used for obstructive sleep apnea (OSA) screening are nasal airflow and oximetry. No studies have directly compared their role in diagnosing OSA at home. STUDY OBJECTIVES: To prospectively compare the diagnostic utility of home-based nasal airflow and oximetry to attended polysomnography (PSG) and to assess the diagnostic value of adding oximetry to nasal airflow for OSA. DESIGN: Cross-sectional study. SETTING: Laboratory and home. PARTICIPANTS: Sleep clinic patients with suspected OSA. INTERVENTIONS: All patients had laboratory PSG and 2 sets of 3 consecutive nights on each device; nasal airflow (Flow Wizard, DiagnoselT, Australia) and oximetry (Radical Set, Masimo, USA) at home in random order. RESULTS: Ninety-eight of the 105 patients enrolled completed home monitoring. The accuracy of nasal airflow respiratory disturbance index (NF RDI) was not different from oximetry (ODI 3%) for diagnosing OSA (area under the ROC curve (AUC) difference, 0.04; 95% CI of difference -0.05 to 0.12; P = 0.43) over 3 nights of at-home recording. The accuracy of NF RDI was higher after 3 nights compared to one night (AUC difference, 0.05; 95% CI of difference, 0.01 to 0.08; P = 0.04). Addition of oximetry to nasal airflow did not increase the accuracy for predicting OSA compared to nasal airflow alone (P > 0.1). CONCLUSIONS: Nasal flow and oximetry have equivalent accuracy for diagnosing OSA in the home setting. Choice of device for home screening of sleep apnea may depend on logistical and service delivery issues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
Validation of a single-channel airflow monitor for screening of sleep-disordered breathing
Nakano, H., Tanigawa, T., Ohnishi, Y., Uemori, H., Senzaki, K., Furukawa, T., & Nishima, S. (2008) · European Respiratory Journal · doi:10.1183/09031936.00130907 · Cited by 43
Cited by
Kapur, V. K., Auckley, D. H., Chowdhuri, S., Kuhlmann, D. C., Mehra, R., Ramar, K., & Harrod, C. G. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6506 · Cited by 3,253
“The performance of the Multivariable Apnea Prediction (MAP) questionnaire has been evaluated against PSG in those with suspected OSA, 35,72–74 a sample of hypertensive patients, 70 and also a sample of older adults 75 with findings of lower levels of specificity and high numbers of false positive…”
Jonas, D. E., Amick, H. R., Feltner, C., Weber, R. P., Arvanitis, M., Stine, A., Lux, L., & Harris, R. P. (2017) · JAMA · doi:10.1001/jama.2016.19635 · Cited by 267
“(AHI) of 15 or greater or an AHI of 5 or greater plus symptoms of disturbed sleep.(17,18)”
BackgroundAbrahamyan, L., Sahakyan, Y., Chung, S., Pechlivanoglou, P., Bielecki, J., Carcone, S. M., Rac, V. E., Fitzpatrick, M., & Krahn, M. (2018) · Sleep and Breathing · doi:10.1007/s11325-017-1615-1 · Cited by 67
Metadata
- Authors
- Rofail, L. M., Wong, K. K. H., Unger, G., Marks, G. B., & Grunstein, R. R.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-08
- Volume
- 33
- Issue
- 8
- Pages
- 1106-1114
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W1494184446
- Cited by
- 45
- References
- 4
- FWCI
- 1.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison between a Single-Channel Nasal Airflow Device and Oximetry for the Diagnosis of Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.1093/sleep/33.8.1106
- The paper
- Rofail, L. M., Wong, K. K. H., Unger, G., Marks, G. B., & Grunstein, R. R. (2010). Comparison between a Single-Channel Nasal Airflow Device and Oximetry for the Diagnosis of Obstructive Sleep Apnea. Sleep. https://doi.org/10.1093/sleep/33.8.1106
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.