CoChat

Refining the Human iPSC-Cardiomyocyte Arrhythmic Risk Assessment Model

Guo, Liang, Coyle, Luke, Abrams, Rory M. C., Kemper, Raymond, Chiao, Eric T., Kolaja, Kyle L. · 2013 · Toxicological Sciences
Cited by 145

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Human induced pluripotent stem cell-derived cardiomyocytes (hiPS-CMs) are capable of detecting drug-induced clinical arrhythmia, Torsade de Pointes (TdP), and QT prolongation. Efforts herein employ a broad set of structurally diverse drugs to optimize the predictive algorithm for applications in discovery toxicology and cardiac safety screening. The changes in the beat rhythm and rate of a confluent monolayer of hiPS-CMs by 88 marketed and 30 internal discovery compounds were detected with real-time cellular impedance measurement and quantified by measures of arrhythmic beating (IB20, lowest concentration inducing ≥ 20% arrhythmic [irregular, atypical] beats in 3 consecutive 20-s sweeps, and predicted proarrhythmic score [PPS]-IB20) or changes in beat rate (BR20, the lowest concentration inducing a reduction in beat rate of ≥ 20% at 3 consecutive sweeps compared with the time-matched vehicle control group, and PPS-BR20). Drug-induced arrhythmic beats and reductions in beat rates are predictive of clinical arrhythmia and QT prolongation, respectively. A threshold of ≤ 10 μM for class determination results in 82% in vitro-in vivo concordance for TdP prediction and 91% sensitivity for non-TdP arrhythmia detection, or 83% and 91% if clinically efficacious plasma (effective serum therapeutic concentration [C eff]) values are incorporated. This human cardiomyocyte arrhythmic risk (hCAR) model provides greater predictivity for torsadogenicity in humans compared with either human ether-a-go-go-related gene (hERG) inhibition (75%) or QT prolongation (81%). The concordance of beat rate reductions to predict clinical QT prolongation is 86%, or 87% when C eff is considered, which is greater than a hERG signal (80%). Further, arrhythmic beats resulting from cytotoxicity were identified by a distinct arrhythmic beating pattern, which occurred after the onset of cytolethality. This hCAR assay showed increased performance over existing preclinical tools in predicting clinical QT prolongation, arrhythmia, and TdP. Thus, hiPS-CMs are a relevant cell system to improve evaluating cardiac safety liabilities of drug candidates.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/toxsci/kft205

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Guo, L., Coyle, L., Abrams, R. M. C., Kemper, R., Chiao, E. T., & Kolaja, K. L.
Venue
Toxicological Sciences
Published
2013-09-18
Volume
136
Issue
2
Pages
581-594
ISSN
  • 1096-0929 (ISSN-L)
  • 1096-6080
OpenAlex
W2133124132
Cited by
145
References
3
FWCI
11.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.