Proarrhythmia Risk Assessment in Human Induced Pluripotent Stem Cell-Derived Cardiomyocytes Using the Maestro MEA Platform
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Evaluation of stem cell-derived cardiomyocytes (SC-CM) using multi-electrode array (MEA) has attracted attention as a novel model to detect drug-induced arrhythmia. An experiment was conducted to determine if MEA recording from human induced pluripotent SC-CM (hiPSC-CM) could assess proarrhythmic risk. Ten hERG blockers, 4 Na(+) blockers, and 1 IKs blocker were evaluated blindly. Eight drugs are associated with Torsades de Pointes (TdP) and 4 are not. Multiple parameters, including field potential duration (FPD), Na(+) slope, Na(+) amplitude, beat rate (BR), and early after-depolarization (EAD) were recorded. Minimum effective concentrations (MEC) that elicited a significant change were calculated. Our results determined that FPD and EAD were unable to distinguish torsadogenic from benign compounds, Na(+) slope and amplitude could not differentiate Na(+) channel blockade from hERG blockade, BR had an inconsistent response to pharmacological treatment, and that hiPSC-CM were, in general, insensitive to IKs inhibition. A ratio was calculated that relates MEC for evoking FPD prolongation, or triggering EAD, to the human therapeutic unbound Cmax (MEC/Cmax). The key finding was that the ratio was sensitive, but specificity was low. Consistently, the ratio had high positive predictive value and low negative predictive value. In conclusion, MEA recordings of hiPSC-CM were sensitive for FPD and EAD detection, but unable to distinguish agents with low- and high-risk for TdPs. Although some published reports suggested great potential for MEA recordings in hSC-CM to assess preclinical cardiac toxicity, the current evaluation implies that this model would have a high false-positive rate in regard to proarrhythmic risk.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
He, J.-Q., Ma, Y., Lee, Y., Thomson, J. A., & Kamp, T. J. (2003) · Circulation Research · doi:10.1161/01.res.0000080317.92718.99 · Cited by 800
Cited by
Induced pluripotent stem cell technology: a decade of progress.
Shi, Y., Inoue, H., Wu, J. C., & Yamanaka, S. (2017) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2016.245 · Cited by 1,525
Human Engineered Heart Tissue: Analysis of Contractile Force
Mannhardt, I., Breckwoldt, K., Letuffe-Brenière, D., Schaaf, S., Schulz, H., Neuber, C., Benzin, A., Werner, T., Eder, A., Schulze, T., et al. (2016) · Stem Cell Reports · doi:10.1016/j.stemcr.2016.04.011 · Cited by 398
Denning, C., Borgdorff, V., Crutchley, J., Firth, K. S. A., George, V., Kalra, S., Kondrashov, A., Hoang, M. D., Mosqueira, D., Patel, A., et al. (2016) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/j.bbamcr.2015.10.014 · Cited by 293
“Maestro n/a CDI iCells Healthy n/a Compounds on FPD 48-well MEA 15-drug p el: hERG blockers, ↑FPD; IKs blocker L768673, No effect on D [181]”
BackgroundNguyen, N., Nguyen, W., Nguyenton, B., Ratchada, P., Page, G., Miller, P. E., Ghetti, A., & Abi-Gerges, N. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.01073 · Cited by 75
Mannhardt, I., Eder, A., Dumotier, B., Prondzynski, M., Krämer, E., Traebert, M., Söhren, K.-D., Flenner, F., Stathopoulou, K., Lemoine, M. D., et al. (2017) · Toxicological Sciences · doi:10.1093/toxsci/kfx081 · Cited by 68
Metadata
- Authors
- Qu, Y., & Vargas, H. M.
- Venue
- Toxicological Sciences
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-06-27
- Volume
- 147
- Issue
- 1
- Pages
- 286-295
- ISSN
- 1096-0929 (ISSN-L)
- 1096-6080
- OpenAlex
- W2339788706
- Cited by
- 79
- References
- 1
- FWCI
- 8.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.