The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Computer Models for Designing Hypertension Experiments and Studying Concepts
Abstract
This paper demonstrates how computer models along with animal experiments have been used to work out the conceptual bases of hypertensive mechanisms, especially the following: (1) The renal-fluid volume pressure control mechanism has a feed-back gain for pressure control of infinity. Therefore, the chronic level to which the arterial pressure is controlled can be changed only by altering this pressure control mechanism. (2) An increase in total peripheral resistance is not sufficient by itself to cause hypertension. The only resistances in the circulatory system that, when increased, will cause hypertension are those along a restricted axis from the root of the aorta to Bowman's capsule in the kidneys. (3) Autoregulation in the peripheral vascular beds does not increase the arterial pressure in hypertension. However, autoregulation can convert high cardiac output hypertension into high peripheral resistance hypertension. (4) In a computer simulation that cannot yet be performed in animals, a simulated hypertension caused by a combination of increased renal afferent and efferent arteriolar resistances has characteristics that match almost exactly those of essential hypertension.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Despite the lack of model validation studies in salt loaded normal controls, these models have been used for many years to probe hypotheses about the possible role of abnormalities in sodium excretion, cardiac output, and vascular resistance in mediating pressor responses to both short-term and long-term salt loading.5, 6, 13, 24, 25”
From Testing Computer Models Predicting Human Responses to a High-Salt Diet: Implications for Understanding Mechanisms of Salt-Sensitive Hypertension (2018) · cites this paper as [6]
Citations
Cites
Circulation: Overall Regulation
Guyton, A. C., Coleman, T. G., & Granger, H. J. (1972) · Annual Review of Physiology · doi:10.1146/annurev.ph.34.030172.000305 · Cited by 870
Self-citationFolkow, B. (1978) · Clinical Science · doi:10.1042/cs055003s · Cited by 403
Physical bases of circulatory transport: Regulation and exchange
(1968) · American Heart Journal · doi:10.1016/0002-8703(68)90104-x · Cited by 231
ARTERIAL PRESSURE AND HYPERTENSION
Brewer, T. F. (1981) · Chest · doi:10.1016/s0012-3692(16)61286-2 · Cited by 193
Role of renal hemodynamics and arterial pressure in aldosterone "escape".
Hall, J. E., Granger, J. P., Smith, M. J., & Premen, A. J. (1984) · Hypertension · doi:10.1161/01.hyp.6.2_pt_2.i183 · Cited by 153
Self-citation
Research works printed but not linked: 1
- Korner, 1982, Causal and homeostatic factors in hypertension, Clin Set, 63, 5s
Cited by
Montani, J., & Van Vliet, B. N. (2009) · Experimental Physiology · doi:10.1113/expphysiol.2008.043299 · Cited by 100
Self-citationThe Obesity Epidemic: Current and Future Pharmacological Treatments
Hofbauer, K. G., Nicholson, J. R., & Boss, O. (2006) · The Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev.pharmtox.47.120505.105256 · Cited by 104
de Mey, C. (1998) · European Urology · doi:10.1159/000052284 · Cited by 60
“Furthermore, pharmacological BP reduction is also subject to homeostatic counter-regulation: the reduced level will only be accepted after the baroreceptor system is ‘reset’ to accept the new, lower level [”
BackgroundSummers, R. L., Ward, K. R., Witten, T. M., Convertino, V. A., Ryan, K. L., Coleman, T. G., & Hester, R. L. (2009) · Resuscitation · doi:10.1016/j.resuscitation.2009.09.001 · Cited by 57
Osborn, J. W., Averina, V. A., & Fink, G. D. (2009) · Experimental Physiology · doi:10.1113/expphysiol.2008.043281 · Cited by 53
“By opposing pressure-induced distension of arterioles, autoregulation greatly reduces the change in ECFV, blood volume and CO that would otherwise be required to increase BP in order to achieve sodium balance (Guyton et al. 1988).”
BackgroundMethodInfluential
Metadata
- Authors
- Guyton, A. C., Montani, J.-P., Hall, J. E., & Manning, R. D.
- Affiliations
- University of Mississippi Medical Center (US)
- Corresponding author
- Guyton, Arthur C.
- ORCID
- Hall, John E.
- Venue
- The American Journal of the Medical Sciences
- Publisher
- Elsevier BV
- Published
- 1988-04
- Volume
- 295
- Issue
- 4
- Pages
- 320-326
- ISSN
- 0002-9629 (ISSN-L)
- OpenAlex
- W2038283374
- Semantic Scholar
- ad9a106a599988c41165e0620ef373dc811fa6d1
- Cited by
- 20
- References
- 5
- Citations by year
- 2024: 1 · 2018: 1 · 2017: 1 · 2015: 1 · 2013: 1 · 2012: 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The American Journal of the Medical Sciences (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Renin-Angiotensin System Studies
- Health Sciences › Medicine › Nephrology › Renal and Vascular Pathologies
- Keywords
- hypertension, computer simulation, feedback gain, systemic vascular resistance, autoregulation, essential hypertension, blood pressure regulation
- MeSH terms
- Animals, Arterioles, Blood Pressure, Cardiac Output, Computer Simulation, Humans, Hypertension, Hypertrophy, Kidney, Models, Biological, Vascular Resistance, Water-Electrolyte Balance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computer Models for Designing Hypertension Experiments and Studying Concepts. https://app.cochat.ai/papers/10.1097/00000441-198804000-00018
- The paper
- Guyton, A. C., Montani, J.-P., Hall, J. E., & Manning, R. D. (1988). Computer Models for Designing Hypertension Experiments and Studying Concepts. The American Journal of the Medical Sciences. https://doi.org/10.1097/00000441-198804000-00018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.