The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Survey of Laryngeal Mask Airway Usage in 11,910 Patients: Safety and Efficacy for Conventional and Nonconventional Usage
Abstract
A survey of laryngeal mask airway (LMA) usage was conducted to provide general information about safety and efficacy with special emphasis on controversial issues such as positive pressure ventilation (PPV), prolonged anesthesia, and laparoscopic and nonlaparoscopic intraabdominal surgery. During the 2-yr study period, of the 39,824 patients who underwent general anesthesia, 11,910 (29.9%) patient airways were managed with the LMA. Forty-four percent underwent PPV. Placement was successful in 99.81%, and in 23 patients the LMA was abandoned in favor of the tracheal tube (TT). Use of the LMA for any intraabdominal procedure was considered nonconventional and occurred in 2222 (18.7%) patients. On 579 occasions procedures lasted > 2 h. A total of 44 critical incidents were documented. Eighteen (0.15%) were related to the airway and none required intensive care management. There were 26 critical incidents not related to the airway which resulted in two admissions to the intensive care unit and one death. There were three cases of failed tracheal intubation managed with the LMA. This survey demonstrates that the LMA technique is safe and effective for both spontaneous and controlled ventilation. Use of the LMA for gynecologic laparoscopy, gynecologic laparotomy, and procedures > 2 h also appears safe.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preventable Anesthesia Mishaps: A Study of Human Factors
Cooper, J. B., Newbower, R. S., Long, C. D., & McPeek, B. (1978) · Anesthesiology · doi:10.1097/00000542-197812000-00004 · Cited by 931
Cooper, J. B., Newbower, R. S., & Kitz, R. J. (1984) · Anesthesiology · doi:10.1097/00000542-198401000-00008 · Cited by 858
The airway: problems and predictions in 18,500 patients
Rose, D. K., & Cohen, M. M. (1994) · Canadian Journal of Anaesthesia · doi:10.1007/bf03009858 · Cited by 645
Brimacombe, J. R., & Berry, A. (1995) · Journal of Clinical Anesthesia · doi:10.1016/0952-8180(95)00026-e · Cited by 310
Self-citationReflux during positive pressure ventilation through the laryngeal mask
Valentine, J., STAKES, A. F., & Bellamy, M. C. (1994) · British Journal of Anaesthesia · doi:10.1093/bja/73.4.543 · Cited by 55
Cited by
The unanticipated difficult airway with recommendations for management
Crosby, E. T., Cooper, R. M., Douglas, M. J., Doyle, D. J., Hung, O. R., Labrecque, P., Muir, H., Murphy, M. F., Preston, R. P., Rose, D. K., et al. (1998) · Canadian Journal of Anaesthesia · doi:10.1007/bf03012147 · Cited by 615
Difficult Airway Society guidelines for awake tracheal intubation (ATI) in adults
Ahmad, I., El‐Boghdadly, K., Bhagrath, R., Hodzovic, I., McNarry, A. F., Mir, F., O'Sullivan, E. P., Patel, A., Stacey, M., & Vaughan, D. (2020) · Anaesthesia · doi:10.1111/anae.14904 · Cited by 563
Complications and failure of airway management
Cook, T. M., & MacDougall-Davis, S. R. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes393 · Cited by 525
Brain, A. I., Verghese, C., Addy, E. V., Kapila, A., & Brimacombe, J. (1997) · British Journal of Anaesthesia · doi:10.1093/bja/79.6.704 · Cited by 323
Self-citationAnesthesia for laparoscopy: a review
Gerges, F. J., Kanazi, G. E., & Jabbour-khoury, S. I. (2006) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2005.01.013 · Cited by 262
Metadata
- Authors
- Verghese, C., & Brimacombe, J. R.
- Venue
- Anesthesia & Analgesia
- Published
- 1996-01
- Volume
- 82
- Issue
- 1
- Pages
- 129-133
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W1966225509
- Cited by
- 348
- References
- 6
- FWCI
- 28.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Survey of Laryngeal Mask Airway Usage in 11,910 Patients: Safety and Efficacy for Conventional and Nonconventional Usage. https://app.cochat.ai/papers/10.1097/00000539-199601000-00023
- The paper
- Verghese, C., & Brimacombe, J. R. (1996). Survey of Laryngeal Mask Airway Usage in 11,910 Patients: Safety and Efficacy for Conventional and Nonconventional Usage. Anesthesia & Analgesia. https://doi.org/10.1097/00000539-199601000-00023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.