The DOI matches its Crossref record.
Preventable Anesthesia Mishaps: A Study of Human Factors
Open accessAbstract
A modified critical-incident analysis technique was used in a retrospective examination of the characteristics of human error and equipment failure in anesthetic practice. The objective was to uncover patterns of frequently occurring incidents that are in need of careful prospective investigation. Forty-seven interviews were conducted with staff and resident anesthesiologists at one urban teaching institution, and descriptions of 359 preventable incidents were obtained. Twenty-three categories of details from these descriptions were subjected to computer-aided analysis for trends and patterns. Most of the preventable incidents involved human error (82 per cent), with breathing-circuit disconnections, inadvertent changes in gas flow, and drug-syringe errors being frequent problems. Overt equipment failures constituted only 14 per cent of the total number of preventable incidents, but equipment design was indictable in many categories of human error, as were inadequate experience and insufficient familiarity with equipment or with the specific surgical procedure. Other factors frequently associated with incidents were inadequate communication among personnel, haste or lack of precaution, and distraction. Results from multi-hospital studies based on the methodology developed could be used for more objective determination of priorities and planning of specific investments for decreasing the risk associated with anesthesia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Defining and Assessing Professional Competence
Epstein, R. M. (2002) · JAMA · doi:10.1001/jama.287.2.226 · Cited by 3,107
Analysis of errors reported by surgeons at three teaching hospitals
Gawande, A. A., Zinner, M. J., Studdert, D. M., & Brennan, T. A. (2003) · Surgery · doi:10.1067/msy.2003.169 · Cited by 1,082
The incidence and nature of surgical adverse events in Colorado and Utah in 1992
Gawande, A. A., Thomas, E. J., Zinner, M. J., & Brennan, T. A. (1999) · Surgery · doi:10.1067/msy.1999.98664 · Cited by 977
Using usability heuristics to evaluate patient safety of medical devices
Zhang, J., Johnson, T. R., Patel, V. L., Paige, D. L., & Kubose, T. (2003) · Journal of Biomedical Informatics · doi:10.1016/s1532-0464(03)00060-1 · Cited by 591
Adverse Sedation Events in Pediatrics: A Critical Incident Analysis of Contributing Factors
Coté, C. J., Notterman, D. A., Karl, H. W., Weinberg, J. A., & McCloskey, C. (2000) · Pediatrics · doi:10.1542/peds.105.4.805 · Cited by 593
Metadata
- Authors
- Cooper, J. B., Newbower, R. S., Long, C. D., & McPeek, B.
- Venue
- Anesthesiology
- Published
- 1978-12-01
- Volume
- 49
- Issue
- 6
- Pages
- 399-406
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1964773302
- Cited by
- 931
- References
- 0
- FWCI
- 29.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Preventable Anesthesia Mishaps: A Study of Human Factors. https://app.cochat.ai/papers/10.1097/00000542-197812000-00004
- The paper
- Cooper, J. B., Newbower, R. S., Long, C. D., & McPeek, B. (1978). Preventable Anesthesia Mishaps: A Study of Human Factors. Anesthesiology. https://doi.org/10.1097/00000542-197812000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.