Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 167

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Prone Positioning Improves Pulmonary Function in Obese Patients During General Anesthesia

Pelosi, Paolo, Croci, Massimo, Calappi, Emiliana, Mulazzi, Davide, Cerisara, Marco, Vercesi, Paola, Vicardi, Pierluigi, Gattinoni, Luciano·1996·Anesthesia & Analgesia

Abstract

We investigated the effects of prone position on functional residual capacity (FRC), the mechanical properties (compliance and resistance) of the total respiratory system, lung and chest wall, and the gas exchange in 10 anesthetized and paralyzed obese (body mass index more than 30 kg/m2) patients, undergoing elective surgery. We used the esophageal balloon technique together with rapid airway occlusions during constant inspiratory flow to partition the mechanics of the respiratory system into its pulmonary and chest wall components. FRC was measured by the helium dilution technique. Measurements were taken in the supine position and after 15-30 min of prone position maintaining the same respiratory pattern (tidal volume 12 mL/kg ideal body weight, respiratory rate 14 breaths/ min, fraction of inspired oxygen [FIO2]0.4). We found that FRC and lung compliance significantly (P < 0.01) increased from the supine to prone position (0.894 +/- 0.327 L vs 1.980 +/- 0.856 L and 91.4 +/- 55.2 mL/cm H2O vs 109.6 +/- 52.4 mL/cm H2O, respectively). On the contrary, the prone position reduced chest wall compliance (199.5 +/- 58.7 mL/cm H2O vs 160.5 +/- 45.4 mL/cm H2O, P < 0.01), thus total respiratory system compliance did not change. Resistance of the total respiratory system, lung, and chest wall were not modified on turning the patients prone. The increase in FRC and lung compliance was paralleled by a significant (P < 0.01) improvement of PaO2 from supine to prone position (130 +/- 31 vs 181 +/- 28 mm Hg, P < 0.01), while PaCO2 was unchanged. We conclude that, in anesthetized and paralyzed obese subjects, the prone position improves pulmonary function, increasing FRC, lung compliance, and oxygenation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000539-199609000-00025

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 167

Metadata

Authors
Pelosi, P., Croci, M., Calappi, E., Mulazzi, D., Cerisara, M., Vercesi, P., Vicardi, P., & Gattinoni, L.
Venue
Anesthesia & Analgesia
Published
1996-09
Volume
83
Issue
3
Pages
578-583
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2092368416
Cited by
167
References
1
FWCI
6.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prone Positioning Improves Pulmonary Function in Obese Patients During General Anesthesia. https://app.cochat.ai/papers/10.1097/00000539-199609000-00025
The paper
Pelosi, P., Croci, M., Calappi, E., Mulazzi, D., Cerisara, M., Vercesi, P., Vicardi, P., & Gattinoni, L. (1996). Prone Positioning Improves Pulmonary Function in Obese Patients During General Anesthesia. Anesthesia & Analgesia. https://doi.org/10.1097/00000539-199609000-00025

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.