Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 387

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Positive End-expiratory Pressure Improves Respiratory Function in Obese but not in Normal Subjects during Anesthesia and Paralysis

Open access
Pelosi, Paolo, Ravagnan, Irene, Giurati, Gabriella, Panigada, Mauro, Bottino, Nicola, Tredici, Stefano, Eccher, Giuditta, Gattinoni, Luciano · 1999 · Anesthesiology

Abstract

Background: Morbidly obese patients, during anesthesia and paralysis, experience more severe impairment of respiratory mechanics and gas exchange than normal subjects. The authors hypothesized that positive end-expiratory pressure (PEEP) induces different responses in normal subjects (n = 9; body mass index < 25 kg/m2) versus obese patients (n = 9; body mass index > 40 kg/m2). Methods: The authors measured lung volumes (helium technique), the elastances of the respiratory system, lung, and chest wall, the pressure-volume curves (occlusion technique and esophageal balloon), and the intraabdominal pressure (intrabladder catheter) at PEEP 0 and 10 cm H2O in paralyzed, anesthetized postoperative patients in the intensive care unit or operating room after abdominal surgery. Results: At PEEP 0 cm H2O, obese patients had lower lung volume (0.59 +/- 0.17 vs. 2.15 +/- 0.58 l [mean +/- SD], P < 0.01); higher elastances of the respiratory system (26.8 +/- 4.2 vs. 16.4 +/- 3.6 cm H2O/l, P < 0.01), lung (17.4 +/- 4.5 vs. 10.3 +/- 3.2 cm H2O/l, P < 0.01), and chest wall (9.4 +/- 3.0 vs. 6.1 +/- 1.4 cm H2O/l, P < 0.01); and higher intraabdominal pressure (18.8 +/-7.8 vs. 9.0 +/- 2.4 cm H2O, P < 0.01) than normal subjects. The arterial oxygen tension was significantly lower (110 +/- 30 vs. 218 +/- 47 mmHg, P < 0.01; inspired oxygen fraction = 50%), and the arterial carbon dioxide tension significantly higher (37.8 +/- 6.8 vs. 28.4 +/- 3.1, P < 0.01) in obese patients compared with normal subjects. Increasing PEEP to 10 cm H2O significantly reduced elastances of the respiratory system, lung, and chest wall in obese patients but not in normal subjects. The pressure-volume curves were shifted upward and to the left in obese patients but were unchanged in normal subjects. The oxygenation increased with PEEP in obese patients (from 110 +/-30 to 130 +/- 28 mmHg, P < 0.01) but was unchanged in normal subjects. The oxygenation changes were significantly correlated with alveolar recruitment (r = 0.81, P < 0.01). Conclusions: During anesthesia and paralysis, PEEP improves respiratory function in morbidly obese patients but not in normal subjects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-199911000-00011

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 387

Metadata

Authors
Pelosi, P., Ravagnan, I., Giurati, G., Panigada, M., Bottino, N., Tredici, S., Eccher, G., & Gattinoni, L.
Venue
Anesthesiology
Published
1999-11-01
Volume
91
Issue
5
Pages
1221-1221
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2019485790
Cited by
387
References
21
FWCI
7.71
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Positive End-expiratory Pressure Improves Respiratory Function in Obese but not in Normal Subjects during Anesthesia and Paralysis. https://app.cochat.ai/papers/10.1097/00000542-199911000-00011
The paper
Pelosi, P., Ravagnan, I., Giurati, G., Panigada, M., Bottino, N., Tredici, S., Eccher, G., & Gattinoni, L. (1999). Positive End-expiratory Pressure Improves Respiratory Function in Obese but not in Normal Subjects during Anesthesia and Paralysis. Anesthesiology. https://doi.org/10.1097/00000542-199911000-00011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.