The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Electroencephalographic Bispectral Index Correlates with Intraoperative Recall and Depth of Propofol-Induced Sedation
Abstract
The bispectral (BIS) index and 95% spectral edge frequency (SEF) of the electroencephalograph (EEG) have been used to study the anesthetic and sedative effects of intravenously (i.v.) administered drugs. This prospective study was designed to evaluate the effectiveness of the BIS index and 95% SEF for assessing the level of propofol-induced sedation and amnesia during regional anesthesia. Ten consenting adult patients undergoing surgery with regional anesthesia were administered propofol in increments of 10-20 mg i.v., every 5-10 min until they became unresponsive to tactile stimulation (i.e., mild prodding or shaking). The BIS index and 95% SEF were continuously recorded from a bifrontal montage (Fp1-Cz and Fp2-Cz) using the Aspect B500 monitor. The depth of sedation was assessed clinically at 5- to 10-min intervals using the observer's assessment of alertness/sedation (OAA/S) scale, with 1 = no response to tactile stimulation to 5 = wide awake. Each patient was shown a picture of an animal (cat) prior to administration of an initial dose of propofol, 40 mg i.v.. Subsequently, patients were administered intermittent bolus doses of propofol, 10-20 mg i.v., and shown different pictures upon achieving OAA/S scores of 4, 3, and 2 during the onset of and recovery from propofol-induced sedation. Picture recall was tested upon arrival of the patient in the postanesthesia care unit (PACU). Of the two EEG variables studied, the BIS index exhibited a better correlation with the OAA/S scores during both the onset (Spearman's rho = 0.744) and recovery (Spearman's rho = 0.705) phases of propofol-induced sedation. With the increasing depth of sedation, there was a progressive decrease in the BIS index (OAA/S score of 5, BIS = 94.5 +/- 2.9; 4, 93.3 +/- 3.3; 3, 89 +/- 6.1; 2, 80.1 +/- 8.7; 1, 75.6 +/- 7.5; mean +/- SD). Conversely, there was a progressive increase in the BIS value during recovery from propofol sedation (OAA/S score of 1, BIS = 75.6 +/- 7.5; 2, 82.4 +/- 10.5; 3, 84.9 +/- 5.9; 4, 93.8 +/- 0.8). Although the changes in the 95% SEF values were less consistent during the onset phase, this EEG variable increased from 16.4 +/- 5.0 to 19.3 +/- 5.6 as the OAA/S score increased from 1 to 4 during the recovery phase. Patient recall of the intraoperative pictures decreased with increasing depth of sedation and decreasing BIS values (OAA/S:% BIS:% recall = 5:94.5 +/- 2.9:100%; 4:93.4 +/- 3:63%; 3:87.3 +/- 6.1:40%; 2:80.8 +/- 8.3:0%; 1:75.6 +/- 7.5:0%). The BIS index appears to be a useful variable for assessing the depth of propofol-induced sedation. Increasing depth of sedation was associated with a significant decrease in intraoperative picture recall.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validity and Reliability of the Observer??s: Assessment of Alertness/Sedation Scale
CHERNIK, D. A., GILLINGS, D., LAINE, H., HENDLER, J., SILVER, J. M., DAVIDSON, A. B., SCHWAM, E. M., & SIEGEL, J. L. (1990) · Journal of Clinical Psychopharmacology · doi:10.1097/00004714-199008000-00003 · Cited by 1,246
Propofol. An update on its clinical use.
Smith, I., White, P. F., Nathanson, M. H., et al. (1994) · PubMed · Cited by 586
Self-citationPropofol: An update on its Clinical Use
Biebuyck, J. F., Smith, I., White, P. F., Nathanson, M., & Gouldson, R. (1994) · Anesthesiology · doi:10.1097/00000542-199410000-00028 · Cited by 394
Self-citationMemory and Awareness in Anaesthesia
Sebel, P. S., Bonke, B., & Winograd, E. (1990) · Medical Entomology and Zoology · Cited by 217
Kearse, L. A., Manberg, P., Chamoun, N., deBros, F., & Zaslavsky, A. (1994) · Anesthesiology · doi:10.1097/00000542-199412000-00010 · Cited by 212
Leslie, K., Sessler, D. I., Schroeder, M., & Walters, K. (1995) · Anesthesia & Analgesia · doi:10.1097/00000539-199512000-00025 · Cited by 174
Propofol Infusion During Regional Anesthesia: Sedative, Amnestic, and Anxiolytic Properties
Smith, I., Monk, T. G., White, P. F., & Ding, Y. (1994) · Anesthesia & Analgesia · doi:10.1213/00000539-199408000-00020 · Cited by 153
Self-citationEEG AND MEMORY EFFECTS OF LOW-DOSE INFUSIONS OF PROPOFOL †
Veselis, R. A., Reinsel, R. A., Wroński, M., Marino, P., TONG, W. P., & Bedford, R. F. (1992) · British Journal of Anaesthesia · doi:10.1093/bja/69.3.246 · Cited by 94
Midazolam in combination with propofol for sedation during local anesthesia
Taylor, E. R., Ghouri, A. F., & White, P. F. (1992) · Journal of Clinical Anesthesia · doi:10.1016/0952-8180(92)90068-c · Cited by 86
Self-citation
Cited by
Update on Bispectral Index monitoring
Johansen, J. W. (2006) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2005.08.004 · Cited by 313
Quantitative EEG correlations with brain glucose metabolic rate during anesthesia in volunteers
Alkire, M. T. (1998) · Anesthesiology · doi:10.1097/00000542-199808000-00007 · Cited by 177
Metadata
- Authors
- Liu, J., Singh, H., & White, P. F.
- Venue
- Anesthesia & Analgesia
- Published
- 1997-01
- Volume
- 84
- Issue
- 1
- Pages
- 185-189
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2139255073
- Cited by
- 432
- References
- 9
- FWCI
- 21.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electroencephalographic Bispectral Index Correlates with Intraoperative Recall and Depth of Propofol-Induced Sedation. https://app.cochat.ai/papers/10.1097/00000539-199701000-00033
- The paper
- Liu, J., Singh, H., & White, P. F. (1997). Electroencephalographic Bispectral Index Correlates with Intraoperative Recall and Depth of Propofol-Induced Sedation. Anesthesia & Analgesia. https://doi.org/10.1097/00000539-199701000-00033
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.