Bispectral Analysis of the Electroencephalogram Correlates with Patient Movement to Skin Incision during Propofol/Nitrous Oxide Anesthesia
Abstract
BACKGROUND: Bispectral analysis is a signal-processing technique that determines the harmonic and phase relations among the various frequencies in the electroencephalogram. Our purpose was to compare the accuracy of a bispectral descriptor, the bispectral index, with that of three power spectral variables (95% spectral edge, median frequency, and relative delta power) in predicting patient movement in response to skin incision during propofol-nitrous oxide anesthesia. METHODS: Forty-four adult patients scheduled for elective noncranial surgery were studied. Gold cup electroencephalographic electrodes were placed on each patient in a frontoparietal montage (Fp1, Fp2, P3, and P4) referred to Cz, and the electroencephalogram was recorded continuously and processed off-line. Conventional frequency bands were used to describe power spectrum variables. Anesthesia was induced with propofol (1.5-3.0 mg-1.kg-1) and maintained with 60% nitrous oxide in oxygen and with propofol at one of three randomized infusion rates (100, 200, or 300 micrograms.kg-1.min-1). Inadequate anesthetic depth was defined as patient movement in response to a 2-cm skin incision at the planned site of surgery. Plasma propofol concentrations were measured within 2 min after skin incision. RESULTS: Complete data were available for 38 patients, of whom 17 moved in response to skin incision. Analysis of the area under the receiver operating characteristic curves showed that only for bispectral index and drug dose group was there a significant predictive relation (area > 0.5). Furthermore, the bispectrum was significantly predictive even after stratification by dose group. CONCLUSIONS: The bispectral index of the electroencephalogram is a more accurate predictor of patient movement in response to skin incision during propofol-nitrous oxide anesthesia than are standard power spectrum parameters or plasma propofol concentrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Glass, P. S., Bloom, M., Kearse, L., Rosow, C., Sebel, P., & Manberg, P. (1997) · Anesthesiology · doi:10.1097/00000542-199704000-00014 · Cited by 1,274
Self-citationClinical Electroencephalography for Anesthesiologists: Part I: Background and Basic Signatures
Purdon, P. L., Sampson, A., Pavone, K. J., & Brown, E. N. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000841 · Cited by 854
General Anesthesia and Altered States of Arousal: A Systems Neuroscience Analysis
Brown, E. N., Purdon, P. L., & Van Dort, C. J. (2011) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-060909-153200 · Cited by 539
Liu, J., Singh, H., & White, P. F. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199701000-00033 · Cited by 432
A Multicenter Study of Bispectral Electroencephalogram Analysis for Monitoring Anesthetic Effect
Sebel, P. S., Lang, E., Rampil, I. J., White, P. F., Cork, R., Jopling, M., Smith, N. T., Glass, P. S. A., & Manberg, P. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199704000-00035 · Cited by 422
Self-citation
Metadata
- Authors
- Kearse, L. A., Manberg, P., Chamoun, N., deBros, F., & Zaslavsky, A.
- Venue
- Anesthesiology
- Published
- 1994-12-01
- Volume
- 81
- Issue
- 6
- Pages
- 1365-1370
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2159198299
- Cited by
- 212
- References
- 0
- FWCI
- 11.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bispectral Analysis of the Electroencephalogram Correlates with Patient Movement to Skin Incision during Propofol/Nitrous Oxide Anesthesia. https://app.cochat.ai/papers/10.1097/00000542-199412000-00010
- The paper
- Kearse, L. A., Manberg, P., Chamoun, N., deBros, F., & Zaslavsky, A. (1994). Bispectral Analysis of the Electroencephalogram Correlates with Patient Movement to Skin Incision during Propofol/Nitrous Oxide Anesthesia. Anesthesiology. https://doi.org/10.1097/00000542-199412000-00010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.