Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 212

The DOI matches its Crossref record.

Bispectral Analysis of the Electroencephalogram Correlates with Patient Movement to Skin Incision during Propofol/Nitrous Oxide Anesthesia

Kearse, Lee A., Manberg, Paul, Chamoun, Nassib, deBros, Fred, Zaslavsky, Alan · 1994 · Anesthesiology

Abstract

BACKGROUND: Bispectral analysis is a signal-processing technique that determines the harmonic and phase relations among the various frequencies in the electroencephalogram. Our purpose was to compare the accuracy of a bispectral descriptor, the bispectral index, with that of three power spectral variables (95% spectral edge, median frequency, and relative delta power) in predicting patient movement in response to skin incision during propofol-nitrous oxide anesthesia. METHODS: Forty-four adult patients scheduled for elective noncranial surgery were studied. Gold cup electroencephalographic electrodes were placed on each patient in a frontoparietal montage (Fp1, Fp2, P3, and P4) referred to Cz, and the electroencephalogram was recorded continuously and processed off-line. Conventional frequency bands were used to describe power spectrum variables. Anesthesia was induced with propofol (1.5-3.0 mg-1.kg-1) and maintained with 60% nitrous oxide in oxygen and with propofol at one of three randomized infusion rates (100, 200, or 300 micrograms.kg-1.min-1). Inadequate anesthetic depth was defined as patient movement in response to a 2-cm skin incision at the planned site of surgery. Plasma propofol concentrations were measured within 2 min after skin incision. RESULTS: Complete data were available for 38 patients, of whom 17 moved in response to skin incision. Analysis of the area under the receiver operating characteristic curves showed that only for bispectral index and drug dose group was there a significant predictive relation (area > 0.5). Furthermore, the bispectrum was significantly predictive even after stratification by dose group. CONCLUSIONS: The bispectral index of the electroencephalogram is a more accurate predictor of patient movement in response to skin incision during propofol-nitrous oxide anesthesia than are standard power spectrum parameters or plasma propofol concentrations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-199412000-00010

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 212

Metadata

Authors
Kearse, L. A., Manberg, P., Chamoun, N., deBros, F., & Zaslavsky, A.
Venue
Anesthesiology
Published
1994-12-01
Volume
81
Issue
6
Pages
1365-1370
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2159198299
Cited by
212
References
0
FWCI
11.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bispectral Analysis of the Electroencephalogram Correlates with Patient Movement to Skin Incision during Propofol/Nitrous Oxide Anesthesia. https://app.cochat.ai/papers/10.1097/00000542-199412000-00010
The paper
Kearse, L. A., Manberg, P., Chamoun, N., deBros, F., & Zaslavsky, A. (1994). Bispectral Analysis of the Electroencephalogram Correlates with Patient Movement to Skin Incision during Propofol/Nitrous Oxide Anesthesia. Anesthesiology. https://doi.org/10.1097/00000542-199412000-00010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.