Comparing Methods of Clinical Measurement: Reporting Standards for Bland and Altman Analysis
The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
UNLABELLED: In this era of medical technology assessment and evidence-based medicine, evaluating new methods to measure physiologic variables is facilitated by standardization of reporting results. It has been proposed that assessing repeatability be followed by assessing agreement with an established technique. If the "limits of agreement" (mean bias +/- 2SD) are not clinically important, then one could use two measurements interchangeably. Generalizability to larger populations is facilitated by reporting confidence intervals. We identified 44 studies that compared methods of clinical measurement published during 1996 to 1998 in seven anesthesia journals. Although 42 of 44 (95.4%) used the limits of agreement methodology for analysis, several inadequacies and inconsistencies in reporting the results were noted. Limits of agreement were defined a priori in 7.1%, repeatability was evaluated in 21.4%, and relationship (pattern) between difference and average was evaluated in 7.1%. Only one of the articles reported confidence intervals. A computer macro for the Minitab statistical package (State College, PA) is described to facilitate reporting of Bland and Altman analysis with confidence intervals. We propose standardization of nomenclature in clinical measurement comparison studies. IMPLICATIONS: A literature review of anesthesia journals revealed several inadequacies and inconsistencies in statistical reports of results of comparison studies with regard to interchangeability of measurement methods. We encourage journal editors to evaluate submissions on this subject carefully to ensure that their readers can draw valid conclusions about the value of new technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Biostatistics: A Methodology for the Health Sciences.
D'Agostino, R. B., Fisher, L. D., & van Belle, G. (1995) · Journal of the American Statistical Association · doi:10.2307/2291095 · Cited by 957
O??Brien, E., Petrie, J., Littler, W., de Swiet, M., Padfield, P. L., O??Malley, K., Jamieson, M., Altman, D., Bland, M., & Atkins, N. (1990) · Journal of Hypertension · doi:10.1097/00004872-199007000-00004 · Cited by 772
Use and Interpretation of Common Statistical Tests in Method Comparison Studies
Westgard, J. O. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.094060 · Cited by 310
Use and Interpretation of Common Statistical Tests in Method-Comparison Studies
Westgard, J. O., & Hunt, M. R. (1973) · Clinical Chemistry · doi:10.1093/clinchem/19.1.49 · Cited by 264
Intraoperative Determination of Cardiac Output Using Multiplane Transesophageal Echocardiography
Perrino, A. C., Harris, S. N., & Luther, M. A. (1998) · Anesthesiology · doi:10.1097/00000542-199808000-00010 · Cited by 175
Créteur, J., Backer, D. D., & Vincent, J. (1997) · Anesthesiology · doi:10.1097/00000542-199709000-00008 · Cited by 136
Gardner, M. J., & Altman, D. G. (1988) · BMJ · doi:10.1136/bmj.296.6631.1210 · Cited by 133
Accuracy of a Cerebral Oximeter in Healthy Volunteers under Conditions of Isocapnic Hypoxia
Henson, L. C., Calalang, C., Temp, J. A., & Ward, D. S. (1998) · Anesthesiology · doi:10.1097/00000542-199801000-00011 · Cited by 122
Noninvasive Monitoring of Carbon Dioxide During Respiratory Failure in Toddlers and Infants
Tobias, J. D., & Meyer, D. J. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199707000-00010 · Cited by 106
Buunk, G., van der Hoeven, J. G., & Meinders, A. E. (1998) · Anaesthesia · doi:10.1046/j.1365-2044.1998.00263.x · Cited by 96
Circulating Blood Volume Measured by Pulse Dye-Densitometry
Iijima, T., Iwao, Y., & Sankawa, H. (1998) · Anesthesiology · doi:10.1097/00000542-199812000-00009 · Cited by 95
Measurement of Cardiac Output by Pulse Dye Densitometry Using Indocyanine Green
Imai, T., Takahashi, K., Fukura, H., & Morishita, Y. (1997) · Anesthesiology · doi:10.1097/00000542-199710000-00015 · Cited by 91
Lardi, A. M., Hirst, C., Mortimer, A. J., & McCollum, C. N. (1998) · Anaesthesia · doi:10.1046/j.1365-2044.1998.00328.x · Cited by 82
Evaluation of the accuracy and response time of stat-mode continuous cardiac output
Lazor, M. A., Pierce, E. T., Stanley, G. D., Cass, J. L., Halpern, E. F., & Bode, R. H. (1997) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(97)90050-1 · Cited by 70
Statistics notes Variables and parameters
Altman, D. G., & Bland, J. M. (1999) · BMJ · doi:10.1136/bmj.318.7199.1667 · Cited by 67
Woltjer, H. H., Bogaard, H. J., Scheffer, G. J., van der Spoel, H. I., Huybregts, M. A. J. M., & VRIES, P. M. J. M. D. (1996) · British Journal of Anaesthesia · doi:10.1093/bja/77.6.748 · Cited by 58
Pulsed Wave Doppler Measurement of Cardiac Output from the Right Ventricular Outflow Tract
Maslow, A. D., Comunale, M. E., Haering, J. M., & Watkins, J. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199609000-00004 · Cited by 56
Oscillometric Blood Pressure Measurements by Different Devices Are Not Interchangeable
Kaufmann, M., Pargger, H., & Drop, L. J. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199602000-00029 · Cited by 54
Hummel, J. M., van Rossum, W., Verkerke, G. J., & Rakhorst, G. (2000) · The International Journal of Artificial Organs · doi:10.1177/039139880002301108 · Cited by 51
Continuous Cardiac Output Monitoring During Adult Liver Transplantation
Greim, C.-A., Roewer, N., Thiel, H., Laux, G., & Esch, J. S. A. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199709000-00003 · Cited by 51
Comparison of esophageal, tympanic, and forehead skin temperatures in adult patients
Patel, N., Smith, C. E., Pinchak, A. C., & Hagen, J. F. (1996) · Journal of Clinical Anesthesia · doi:10.1016/0952-8180(96)00103-1 · Cited by 49
Weiss, B., Spahn, D. R., Rahmig, H., Rohling, R. G., & Pasch, T. (1996) · British Journal of Anaesthesia · doi:10.1093/bja/76.3.405 · Cited by 48
Thangathurai, D., Charbonnet, C., Roessler, P., Wo, C. C. J., Mikhail, M., Yoshida, R., & Shoemaker, W. C. (1997) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(97)90052-5 · Cited by 43
Gust, R., Gottschalk, A., Bauer, H., Böttiger, B. W., Bohrer, H., & Martin, E. (1998) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(98)90093-3 · Cited by 41
Medical Technology Assessment: An Overview
Fleisher, L. A., Mantha, S., & Roizen, M. F. (1998) · Anesthesia & Analgesia · doi:10.1097/00000539-199812000-00012 · Cited by 40
Self-citationZollinger, A., Spahn, D. R., Singer, T., Zalunardo, M. P., Stoehr, S., Weder, W., & Pasch, T. (1997) · British Journal of Anaesthesia · doi:10.1093/bja/79.1.47 · Cited by 38
Matsukawa, T., Ozaki, M., Hanagata, K., Iwashita, H., Miyaji, T., & Kumazawa, T. (1996) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03013429 · Cited by 30
Cardiac output during liver transplantation
Colbert, S., O'Hanlon, D. M., Duranteau, J., & Ecoflfey, C. (1998) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03013251 · Cited by 30
Perioperative on-site haemoglobin determination: as accurate as laboratory values?
Jaeger, M. T., Ashbury, T. L., Adams, M. A., & Duncan, P. G. (1996) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03013031 · Cited by 26
Wahr, J. A., Yun, J.-H., Yang, V. C.-M., Lee, L. M., Fu, B., & Meyerhoff, M. E. (1996) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(05)80002-3 · Cited by 26
Jugular Venous Bulb Oxyhemoglobin Saturation During Cardiac Surgery
Trubiano, P., Heyer, E. J., Adams, D. C., McMahon, D. J., Christiansen, I., Rose, E. A., & Delphin, E. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199605000-00013 · Cited by 26
Are coagulation studies on blood sampled from arterial lines valid?
Heap, M. J., Ridley, S., Hodson, K., & Martos, F. J. (1997) · Anaesthesia · doi:10.1111/j.1365-2044.1997.148-az0152.x · Cited by 25
Continuous intra-arterial blood gas monitoring during oesophagectomy
Ishikawa, S., Makita, K., Nakazawa, K., & Amaha, K. (1998) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03012916 · Cited by 24
Sekimoto, M., Fukui, M., & Fujita, K. (1997) · Anaesthesia · doi:10.1111/j.1365-2044.1997.249-az0389.x · Cited by 22
Gastric tonometry: in vivo comparison of saline and air tonometry in patients with cardiogenic shock
Janssens, U., Graf, J., Koch, K.-C., & Hanrath, P. (1998) · British Journal of Anaesthesia · doi:10.1093/bja/81.5.676 · Cited by 21
Nakata, Y., Goto, T., Saito, H., Ichinose, F., Uezono, S., Suwa, K., & Morita, S. (1998) · Journal of Clinical Anesthesia · doi:10.1016/s0952-8180(98)00006-3 · Cited by 19
Central venous pressure from common iliac vein reflects right atrial pressure
Alzeer, A. H., Arora, S., Ansari, Z., Fayed, D. F., & Naguib, M. (1998) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03012153 · Cited by 15
Monitoring of pH and PCO2 in children using the Paratrend 7 in a peripheral vein
Tobias, J. D., Meyer, D. J., & Helikson, M. A. (1998) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03012000 · Cited by 14
Greim, C. A., Roewer, N., Laux, G., & Esch, J. S. A. (1996) · British Journal of Anaesthesia · doi:10.1093/bja/77.3.365 · Cited by 13
Wajon, P., & Lindsay, G. (1998) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(98)90231-2 · Cited by 13
Kolev, N. S., Brase, R., Wolner, E., & ZIMPFER, M. (1998) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(98)90050-7 · Cited by 11
Evaluation of a new semi-continuous cardiac output system in the intensive care unit
Seguin, P., Colcanap, O., Rouzo, A. L., Tanguy, M., Guillou, Y., & Mallédant, Y. (1998) · Canadian Journal of Anaesthesia-journal Canadien D Anesthesie · doi:10.1007/bf03012713 · Cited by 10
Technology assessment of anesthesia monitors
Pace, N. L. (1992) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf01617435 · Cited by 8
Franklin, M. L., Peruzzi, W. T., Moen, S. G., & Shapiro, B. A. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199609000-00010 · Cited by 5
Use of a neonatal noninvasive blood pressure module on adult patients
GREEN, D. W. (1996) · Anaesthesia · doi:10.1111/j.1365-2044.1996.tb15049.x · Cited by 4
Cardiac output estimation by visual inspection vs thermodilution during cardiac surgery
Aye, T., Milne, B., & Ballantyne, M. (1997) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03012999 · Cited by 3
Cited by
Dewitte, K., Fierens, C., Stöckl, D., & Thienpont, L. M. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.5.799 · Cited by 359
Interobserver agreement issues in radiology
Benchoufi, M., Matzner-Lober, E., Molinari, N., Jannot, A.-S., & Soyer, P. (2020) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2020.09.001 · Cited by 317
Design, Analysis, and Interpretation of Method-Comparison Studies
Hanneman, S. K. (2008) · AACN Advanced Critical Care · doi:10.1097/01.aacn.0000318125.41512.a3 · Cited by 306
Reporting Standards for a Bland–Altman Agreement Analysis: A Review of Methodological Reviews
Gerke, O. (2020) · Diagnostics · doi:10.3390/diagnostics10050334 · Cited by 246
Exact Parametric Confidence Intervals for Bland-Altman Limits of Agreement
Carkeet, A. (2015) · Optometry and Vision Science · doi:10.1097/opx.0000000000000513 · Cited by 215
“Bland-Altman plots usually also include horizontal lines to denote 95% LoAs.”
BackgroundResultInfluential
Metadata
- Authors
- Mantha, S., Roizen, M. F., Fleisher, L. A., Thisted, R., & Foss, J.
- Venue
- Anesthesia & Analgesia
- Published
- 2000-03
- Volume
- 90
- Issue
- 3
- Pages
- 593-602
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2143660976
- Cited by
- 266
- References
- 50
- FWCI
- 13.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.