The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems
Abstract
With the increasing manufacture of expensive systems for the measurement of ambulatory blood pressure there is a need for potential purchasers to be able to satisfy themselves that the systems have been evaluated according to agreed criteria. The British Hypertension Society has, therefore, drawn up a protocol of requirements for the evaluation of these devices. This protocol incorporates many features of the American National Standard for Non-Automated Sphygmomanometers but includes many additional features, such as strict criteria for observer training, interdevice variability testing before and after a month of ambulatory use, and a new system of analysis which permits the test system to be graded. It is recommended that manufacturers of ambulatory blood pressure measuring devices should obtain an unbiased evaluation according to a recognized standard before a device is marketed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Self-citationPickering, T. G. (1982) · JAMA · doi:10.1001/jama.247.7.992 · Cited by 526
Recommendations on blood pressure measurement.
Petrie, J. C., O'Brien, E. T., Littler, W. A., & de Swiet, M. (1986) · BMJ · doi:10.1136/bmj.293.6547.611 · Cited by 396
Self-citationA RANDOM-ZERO SPHYGMOMANOMETER
Weight, B. M., & Dore, C. F. (1970) · The Lancet · doi:10.1016/s0140-6736(70)90709-9 · Cited by 319
Prognostic value of ambulatory blood pressure measurements: further analyses.
Perloff, D. L., Sokolow, M., Cowan, R., & Juster, R. P. (1989) · PubMed · Cited by 209
Circadian blood pressure patterns in ambulatory hypertensive patients
Drayer, J. I. M., Weber, M. A., Deyoung, J. L., & Wyle, F. A. (1982) · The American Journal of Medicine · doi:10.1016/0002-9343(82)90327-8 · Cited by 137
Evaluation of performance of selected devices for measuring blood pressure
Labarthe, D. R., HAWKINS, C. M., & Remington, R. D. (1973) · The American Journal of Cardiology · doi:10.1016/s0002-9149(73)80046-3 · Cited by 111
Inaccuracy of seven popular sphygmomanometers for home measurement of blood pressure
Brien, E. O., Mee, F., Atkins, N., & O??Malley, K. (1990) · Journal of Hypertension · doi:10.1097/00004872-199007000-00005 · Cited by 71
Self-citationTHE RANDOM-ZERO VERSUS THE STANDARD MERCURY SPHYGMOMANOMETER: A SYSTEMATIC BLOOD PRESSURE DIFFERENCE
Gaudemaris, R. D., Folsom, A. R., Prineas, R. J., & Luepker, R. V. (1985) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a113998 · Cited by 58
Cited by
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationStaessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Human blood pressure determination by sphygmomanometry.
Perloff, D., Grim, C., Flack, J., Frohlich, E. D., Hill, M., McDonald, M., & Morgenstern, B. Z. (1993) · Circulation · doi:10.1161/01.cir.88.5.2460 · Cited by 1,591
Blood pressure measuring devices: recommendations of the European Society of Hypertension
O'Brien, E., Waeber, B., Parati, G., Staessen, J., & Myers, M. G. (2001) · BMJ · doi:10.1136/bmj.322.7285.531 · Cited by 903
Self-citation
Metadata
- Authors
- O??Brien, E., Petrie, J., Littler, W., de Swiet, M., Padfield, P. L., O??Malley, K., Jamieson, M., Altman, D., Bland, M., & Atkins, N.
- Venue
- Journal of Hypertension
- Published
- 1990-07
- Volume
- 8
- Issue
- 7
- Pages
- 607-619
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2166451543
- Cited by
- 772
- References
- 17
- FWCI
- 17.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems. https://app.cochat.ai/papers/10.1097/00004872-199007000-00004
- The paper
- O??Brien, E., Petrie, J., Littler, W., de Swiet, M., Padfield, P. L., O??Malley, K., Jamieson, M., Altman, D., Bland, M., & Atkins, N. (1990). The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems. Journal of Hypertension. https://doi.org/10.1097/00004872-199007000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.