The DOI matches its Crossref record.
Voluven®, a Lower Substituted Novel Hydroxyethyl Starch (HES 130/0.4), Causes Fewer Effects on Coagulation in Major Orthopedic Surgery than HES 200/0.5
Abstract
UNLABELLED: Hydroxyethyl starch (HES) solutions are effective plasma volume expanders. Impairment of coagulation occurs with large HES volumes infused perioperatively. Therefore, a lower substituted novel HES (Voluven; Fresenius Kabi, Bad Homburg, Germany) was developed to minimize hemostatic interactions, and was compared with HAES-steril (Fresenius Kabi) (pentastarch) regarding safety and efficacy. We performed a prospective, randomized, double-blinded study in 100 major orthopedic surgery patients. Because the 95% confidence interval (-330 mL; +284 mL) for the treatment contrast Voluven-HAES-steril was entirely included in the predefined equivalence range (+/- 500 mL), comparable efficacy was established. Voluven interfered significantly less than HAES-steril with coagulation factor VIII levels and partial thromboplastin time postoperatively. Total amounts of red blood cells transfused were comparable between the Voluven and HAES-steril groups, but a significantly reduced need for homologous red blood cells was observed in the Voluven group. We conclude that in large-blood-loss surgery, Voluven has a comparable efficacy with HAES-steril and may reduce coagulation impairment, possibly leading to a smaller number of allogeneic blood transfusions. IMPLICATIONS: Hydroxyethyl starches are common plasma volume expanders, but may interfere with coagulation at large doses. We tested a novel hydroxyethyl starch specification (Voluven; Fresenius Kabi, Bad Homburg, Germany) which was developed to reduce hemostatic interactions while preserving its efficacy in restoring plasma volume in comparison to HAES-steril (pentastarch; Fresenius Kabi) in major orthopedic surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Management of severe perioperative bleeding: Guidelines from the European Society of Anaesthesiology
Kozek-Langenecker, S. A., Afshari, A., Albaladejo, P., Santullano, C. A. A., De Robertis, E., Filipescu, D. C., Fries, D., Görlinger, K., Haas, T., Imberger, G., et al. (2013) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32835f4d5b · Cited by 909
Perioperative Fluid Management and Clinical Outcomes in Adults
Grocott, M. P. W., Mythen, M. G., & Gan, T. J. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000148691.33690.ac · Cited by 404
Hydroxyethyl Starches: Different Products – Different Effects
Westphal, M., James, M. F. M., Kozek-Langenecker, S., Stocker, R., Guidet, B., Van Aken, H., & Warner, M. A. (2009) · Anesthesiology · doi:10.1097/aln.0b013e3181a7ec82 · Cited by 383
Tan, M. L., Choong, P. F. M., & Dass, C. R. (2010) · Peptides · doi:10.1016/j.peptides.2009.10.002 · Cited by 350
Massive transfusion and coagulopathy: pathophysiology and implications for clinical management
Hardy, J.-F., Moerloose, P. D., & Samama, C. M. (2006) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03022251 · Cited by 293
Metadata
- Authors
- Langeron, O., Doelberg, M., Ang, E.-T., Bonnet, F., Capdevila, X., & Coriat, P.
- Venue
- Anesthesia & Analgesia
- Published
- 2001-04
- Volume
- 92
- Issue
- 4
- Pages
- 855-862
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W1996447886
- Cited by
- 228
- References
- 0
- FWCI
- 9.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Voluven®, a Lower Substituted Novel Hydroxyethyl Starch (HES 130/0.4), Causes Fewer Effects on Coagulation in Major Orthopedic Surgery than HES 200/0.5. https://app.cochat.ai/papers/10.1097/00000539-200104000-00011
- The paper
- Langeron, O., Doelberg, M., Ang, E.-T., Bonnet, F., Capdevila, X., & Coriat, P. (2001). Voluven®, a Lower Substituted Novel Hydroxyethyl Starch (HES 130/0.4), Causes Fewer Effects on Coagulation in Major Orthopedic Surgery than HES 200/0.5. Anesthesia & Analgesia. https://doi.org/10.1097/00000539-200104000-00011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.