Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 228

The DOI matches its Crossref record.

Voluven®, a Lower Substituted Novel Hydroxyethyl Starch (HES 130/0.4), Causes Fewer Effects on Coagulation in Major Orthopedic Surgery than HES 200/0.5

Langeron, Olivier, Doelberg, Martin, Ang, Eng-Than, Bonnet, Francis, Capdevila, Xavier, Coriat, Pierre · 2001 · Anesthesia & Analgesia

Abstract

UNLABELLED: Hydroxyethyl starch (HES) solutions are effective plasma volume expanders. Impairment of coagulation occurs with large HES volumes infused perioperatively. Therefore, a lower substituted novel HES (Voluven; Fresenius Kabi, Bad Homburg, Germany) was developed to minimize hemostatic interactions, and was compared with HAES-steril (Fresenius Kabi) (pentastarch) regarding safety and efficacy. We performed a prospective, randomized, double-blinded study in 100 major orthopedic surgery patients. Because the 95% confidence interval (-330 mL; +284 mL) for the treatment contrast Voluven-HAES-steril was entirely included in the predefined equivalence range (+/- 500 mL), comparable efficacy was established. Voluven interfered significantly less than HAES-steril with coagulation factor VIII levels and partial thromboplastin time postoperatively. Total amounts of red blood cells transfused were comparable between the Voluven and HAES-steril groups, but a significantly reduced need for homologous red blood cells was observed in the Voluven group. We conclude that in large-blood-loss surgery, Voluven has a comparable efficacy with HAES-steril and may reduce coagulation impairment, possibly leading to a smaller number of allogeneic blood transfusions. IMPLICATIONS: Hydroxyethyl starches are common plasma volume expanders, but may interfere with coagulation at large doses. We tested a novel hydroxyethyl starch specification (Voluven; Fresenius Kabi, Bad Homburg, Germany) which was developed to reduce hemostatic interactions while preserving its efficacy in restoring plasma volume in comparison to HAES-steril (pentastarch; Fresenius Kabi) in major orthopedic surgery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000539-200104000-00011

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 228

Metadata

Authors
Langeron, O., Doelberg, M., Ang, E.-T., Bonnet, F., Capdevila, X., & Coriat, P.
Venue
Anesthesia & Analgesia
Published
2001-04
Volume
92
Issue
4
Pages
855-862
ISSN
0003-2999 (ISSN-L)
OpenAlex
W1996447886
Cited by
228
References
0
FWCI
9.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Voluven®, a Lower Substituted Novel Hydroxyethyl Starch (HES 130/0.4), Causes Fewer Effects on Coagulation in Major Orthopedic Surgery than HES 200/0.5. https://app.cochat.ai/papers/10.1097/00000539-200104000-00011
The paper
Langeron, O., Doelberg, M., Ang, E.-T., Bonnet, F., Capdevila, X., & Coriat, P. (2001). Voluven®, a Lower Substituted Novel Hydroxyethyl Starch (HES 130/0.4), Causes Fewer Effects on Coagulation in Major Orthopedic Surgery than HES 200/0.5. Anesthesia & Analgesia. https://doi.org/10.1097/00000539-200104000-00011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.