A Comparison of the INVOS 4100 and the NIRO 300 Near-Infrared Spectrophotometers

Yoshitani, Kenji, Kawaguchi, Masahiko, Tatsumi, Kazuyuki, Kitaguchi, Katsuyasu, Furuya, Hitoshi · 2002 · Anesthesia & Analgesia

Abstract

UNLABELLED: We determined whether two different devices for measuring near-infrared spectroscopy (NIRS)---the INVOS 4100 and the NIRO 300---produce similar cerebral oxygenation data during the CO(2) challenge test. Nineteen patients anesthetized with sevoflurane, 67% nitrous oxide in oxygen, and fentanyl were studied. A series of measurements of regional cerebral oxygen saturation (rSO(2)), measured by the INVOS 4100, and tissue oxygen index (TOI), measured by the NIRO 300, were performed in the following conditions: 1) normocapnia (PaCO(2), 35--45 mm Hg); 2) hypocapnia (PaCO(2), 25--35 mm Hg); 3) normocapnia; and 4) hypercapnia (PaCO(2), 45--55 mm Hg). Hemodynamic variables, including arterial blood gases and cerebral blood flow velocity, were measured at the same time with transcranial Doppler. The values and percentage changes of rSO(2) and TOI were compared by using regression analysis and Bland and Altman analysis. The rSO(2) showed a significant positive correlation with TOI (r = 0.58, P < 0.01). The percentage change of rSO(2) also showed a significant positive correlation with the percentage change of TOI during the CO(2) challenge (r = 0.85, P < 0.01). Bland and Altman analysis revealed a bias of -0.5% with 2 SD of 15.6% when comparing the rSO(2) value with the TOI value, and it showed a bias of -3.4% with 2 SD of 15.2% when comparing the percentage change of rSO(2) with the percentage change of TOI, indicating unacceptable disagreement of these data. These results indicate that cerebral oxygen saturation and its relative change during the CO(2) challenge may vary depending on the type of NIRS used. Because the measurement technique and algorithm were different in each device, we should carefully consider the clinical application of the values produced by NIRS. IMPLICATIONS: Near-infrared spectroscopy (NIRS) has been proposed as a noninvasive clinical method for assessing cerebral oxygenation. The acceptable reliability and validity of NIRS values have not been established despite their widespread use. The INVOS 4100 and the NIRO 300 can display cerebral oxygen saturation as regional cerebral oxygen saturation and tissue oxygenation index, but they produce differing results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000539-200203000-00020

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 162

Metadata

Authors
Yoshitani, K., Kawaguchi, M., Tatsumi, K., Kitaguchi, K., & Furuya, H.
Venue
Anesthesia & Analgesia
Published
2002-03
Volume
94
Issue
3
Pages
586-590
ISSN
0003-2999 (ISSN-L)
OpenAlex
W1967137016
Cited by
162
References
1
FWCI
8.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Comparison of the INVOS 4100 and the NIRO 300 Near-Infrared Spectrophotometers. https://app.cochat.ai/papers/10.1097/00000539-200203000-00020
The paper
Yoshitani, K., Kawaguchi, M., Tatsumi, K., Kitaguchi, K., & Furuya, H. (2002). A Comparison of the INVOS 4100 and the NIRO 300 Near-Infrared Spectrophotometers. Anesthesia & Analgesia. https://doi.org/10.1097/00000539-200203000-00020

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.