The DOI matches its Crossref record.
The Effect of Carbon Monoxide Inhalation on Pulse Oximetry and Transcutaneous Po 2
Abstract
Five dogs were anesthetized, intubated, and ventilated with various mixtures of oxygen, nitrogen, and carbon monoxide. Each dog was monitored with arterial and pulmonary artery catheters, a transcutaneous PO2 analyzer, and two pulse oximeters. An IL-282 Co-oximeter was used to periodically measure arterial oxyhemoglobin (O2Hb) and carboxyhemoglobin (COHb) as percentages of the total hemoglobin. The PaO2, PaCO2, and pHa were measured in the same blood specimens using standard electrodes. When the inspired oxygen concentration was reduced in the absence of COHb, the pulse oximeter saturation (SpO2) estimated O2Hb with reasonable accuracy. COHb levels were then varied slowly from 0-75% in each dog. As the COHb level increased and oxyhemoglobin decreased, both pulse oximeters continued to read an oxygen saturation of greater than 90%, while the actual O2Hb fell below 30%. In the presence of COHb, the SpO2 is approximately the sum of COHb and O2Hb, and, thus, may seriously overestimate O2Hb. The pulse oximeter, as the sole indicator of blood oxygenation, should, therefore, be used with caution in patients with recent carbon monoxide exposure. On the other hand, transcutaneous PO2 falls linearly as COHb increases, and reaches about one-fifth of its initial value at the highest COHb levels despite the maintenance of constant arterial PO2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pulse oximetry: Understanding its basic principles facilitates appreciation of its limitations
Chan, E. D., Chan, M. M., & Chan, M. M. (2013) · Respiratory Medicine · doi:10.1016/j.rmed.2013.02.004 · Cited by 710
Pulse oximetry: Principles and limitations
Sinex, J. E. (1999) · The American Journal of Emergency Medicine · doi:10.1016/s0735-6757(99)90019-0 · Cited by 481
Pharmacogenetics, Drug-Metabolizing Enzymes, and Clinical Practice
Gardiner, S. J., & Begg, E. J. (2006) · Pharmacological Reviews · doi:10.1124/pr.58.3.6 · Cited by 406
Cyanide poisoning and its treatment
Gracia, R., & Shepherd, G. (2004) · Pharmacotherapy The Journal of Human Pharmacology and Drug Therapy · doi:10.1592/phco.24.14.1358.43149 · Cited by 173
Effect of skin pigmentation on pulse oximetry accuracy in the emergency department
Adler, J. N., Hughes, L. A., Vtvilecchia, R., & Jr., C. A. C. (1998) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.1998.tb02772.x · Cited by 102
Metadata
- Authors
- Barker, S. J., & Tremper, K. K.
- Venue
- Anesthesiology
- Published
- 1987-05-01
- Volume
- 66
- Issue
- 5
- Pages
- 677-679
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2151897902
- Cited by
- 281
- References
- 0
- FWCI
- 14.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Effect of Carbon Monoxide Inhalation on Pulse Oximetry and Transcutaneous Po 2. https://app.cochat.ai/papers/10.1097/00000542-198705000-00014
- The paper
- Barker, S. J., & Tremper, K. K. (1987). The Effect of Carbon Monoxide Inhalation on Pulse Oximetry and Transcutaneous Po 2. Anesthesiology. https://doi.org/10.1097/00000542-198705000-00014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.