CoChat

Testing Computer-controlled Infusion Pumps by Simulation

Shafer, Steven L., Siegel, Lawrence C., Cooke, James E., Scott, James C. · 1988 · Anesthesiology
Cited by 90

The DOI matches its Crossref record.

Abstract

The pharmacokinetic behavior of intravenous anesthetic drugs can be described by two- or three-compartment models. Rapid achievement and maintenance of steady plasma concentrations of these drugs requires a complicated delivery scheme, perhaps best controlled by a computer. The authors developed a method of simulating the performance of a computer-controlled infusion pump from the differential equations describing drug transfer between compartments. They also derived a mathematically simple and flexible approximate solution to these equations using Euler's numerical method. They incorporated this approximate solution into a computer-controlled infusion pump for intravenous drugs. They tested their pump by simulating the administration of fentanyl to a hypothetical patient whose fentanyl pharmacokinetics were described by a three-compartment model. The exact analytical solution served as the standard of comparison. The approximation technique, using a 15-s interval between model updates, had a maximum error of 0.35 ng.ml-1, and rapidly converged on the exact solution. The simulations revealed oscillations in the system. The authors suggest that such simulations be used to evaluate computer-controlled infusion pumps prior to clinical trials of these devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-198802000-00013

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 90

Metadata

Authors
Shafer, S. L., Siegel, L. C., Cooke, J. E., & Scott, J. C.
Venue
Anesthesiology
Published
1988-02-01
Volume
68
Issue
2
Pages
261-266
ISSN
0003-3022 (ISSN-L)
OpenAlex
W1988364699
Cited by
90
References
0
FWCI
3.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Testing Computer-controlled Infusion Pumps by Simulation. https://app.cochat.ai/papers/10.1097/00000542-198802000-00013
The paper
Shafer, S. L., Siegel, L. C., Cooke, J. E., & Scott, J. C. (1988). Testing Computer-controlled Infusion Pumps by Simulation. Anesthesiology. https://doi.org/10.1097/00000542-198802000-00013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.