Abstract
The pharmacokinetic behavior of intravenous anesthetic drugs can be described by two- or three-compartment models. Rapid achievement and maintenance of steady plasma concentrations of these drugs requires a complicated delivery scheme, perhaps best controlled by a computer. The authors developed a method of simulating the performance of a computer-controlled infusion pump from the differential equations describing drug transfer between compartments. They also derived a mathematically simple and flexible approximate solution to these equations using Euler's numerical method. They incorporated this approximate solution into a computer-controlled infusion pump for intravenous drugs. They tested their pump by simulating the administration of fentanyl to a hypothetical patient whose fentanyl pharmacokinetics were described by a three-compartment model. The exact analytical solution served as the standard of comparison. The approximation technique, using a 15-s interval between model updates, had a maximum error of 0.35 ng.ml-1, and rapidly converged on the exact solution. The simulations revealed oscillations in the system. The authors suggest that such simulations be used to evaluate computer-controlled infusion pumps prior to clinical trials of these devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ketamine: A Review of Clinical Pharmacokinetics and Pharmacodynamics in Anesthesia and Pain Therapy
Peltoniemi, M. A., Hagelberg, N. M., Olkkola, K. T., & Saari, T. I. (2016) · Clinical Pharmacokinetics · doi:10.1007/s40262-016-0383-6 · Cited by 672
“In this study, a targetcontrolled infusion was used with a serum ketamine target set at 300 ng/mL, using STANPUMP software [77].”
Effects of Subanesthetic Ketamine on Regional Cerebral Glucose Metabolism in Humans
Långsjö, J. W., Salmi, E., Kaisti, K. K., Aalto, S., Hinkka, S., Aantaa, R., Oikonen, V., Viljanen, T., Kurki, T., Silvanto, M., et al. (2004) · Anesthesiology · doi:10.1097/00000542-200405000-00006 · Cited by 123
Importance of Chronopharmacokinetics in Design and Evaluation of Transdermal Drug Delivery Systems
Gries, J.-M., Benowitz, N., & Verotta, D. (1998) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(24)37450-6 · Cited by 20
“If reaching the target rapidly is important, it is necessary to include an early phase (first 4 hr) with an high delivery rate, followed by an exponential decay (Shafer et al., 1988).”
Metadata
- Authors
- Shafer, S. L., Siegel, L. C., Cooke, J. E., & Scott, J. C.
- Venue
- Anesthesiology
- Published
- 1988-02-01
- Volume
- 68
- Issue
- 2
- Pages
- 261-266
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1988364699
- Cited by
- 90
- References
- 0
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Testing Computer-controlled Infusion Pumps by Simulation. https://app.cochat.ai/papers/10.1097/00000542-198802000-00013
- The paper
- Shafer, S. L., Siegel, L. C., Cooke, J. E., & Scott, J. C. (1988). Testing Computer-controlled Infusion Pumps by Simulation. Anesthesiology. https://doi.org/10.1097/00000542-198802000-00013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.