Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 322

The DOI matches its Crossref record.

Electroencephalographic Quantitation of Opioid Effect: Comparative Pharmacodynamics of Fentanyl and Sufentanil

Open access
Scott, James C., Cooke, James E., Stanski, Donald R.·1991·Anesthesiology

Abstract

The authors compared the pharmacodynamics of sufentanil with those of fentanyl using the electroencephalogram (EEG) as a measure of opioid drug effect. Sixteen patients were given a rapid infusion of sufentanil (18.75 micrograms/min) during EEG recording. To quantitate the opioid-induced slowing of the EEG, the authors analyzed its power spectrum and calculated the spectral edge. An inhibitory sigmoid Emax model of the maximal decrease in spectral edge produced by the opioid related spectral edge values to serum concentrations of sufentanil. The resulting data for the pharmacodynamic parameters of sufentanil were compared with fentanyl parameters that were obtained by reanalysis from an identically conducted, previously published study. The half-time of blood-brain equilibration (T1/2Keo) was not statistically different between sufentanil and fentanyl (6.2 +/- 2.8 vs. 6.6 +/- 1.7 min, mean +/- SD, respectively). The intrinsic potency of sufentanil, as measured by the serum concentration needed to cause half the maximal EEG slowing (IC50), was 12-fold greater (0.68 +/- 0.31 ng/ml) than that of fentanyl (8.1 +/- 2.2 ng/ml). The second part of the study verified the hypothesis that administration of equipotent bolus doses would produce equal onset times. Bolus injections of either 125 micrograms of sufentanil or 1,250 micrograms of fentanyl were given during EEG recording. The time from injection to 50% maximal EEG slowing (T50) was calculated for each patient. The values for T50 for the two groups did not differ. The authors conclude that fentanyl and sufentanil have similar pharmacodynamic profiles, the former being 12 times more potent than the latter.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-199101000-00007

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 322

Metadata

Authors
Scott, J. C., Cooke, J. E., & Stanski, D. R.
Venue
Anesthesiology
Published
1991-01-01
Volume
74
Issue
1
Pages
34-42
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2114588857
Cited by
322
References
0
FWCI
8.30
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electroencephalographic Quantitation of Opioid Effect: Comparative Pharmacodynamics of Fentanyl and Sufentanil. https://app.cochat.ai/papers/10.1097/00000542-199101000-00007
The paper
Scott, J. C., Cooke, J. E., & Stanski, D. R. (1991). Electroencephalographic Quantitation of Opioid Effect: Comparative Pharmacodynamics of Fentanyl and Sufentanil. Anesthesiology. https://doi.org/10.1097/00000542-199101000-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.