Monitoring Electrophysiologic Function during Carotid Endarterectomy: A Comparison of Somatosensory Evoked Potentials and Conventional Electroencephalogram
Abstract
There is no consensus as to the most appropriate monitor for detecting ischemia during carotid endarterectomy. Accordingly, simultaneous 16-channel continuous electroencephalogram (EEG) and somatosensory evoked potential (SSEP) monitoring were performed in 64 normocapnic patients undergoing carotid endarterectomy and anesthetized with isoflurane or halothane-nitrous oxide (supplemented with fentanyl). Recordings were obtained before, during, and for 15 min after cross-clamping of the internal carotid artery. Internal shunt was not used in any patient, regardless of EEG and SSEP changes. Significant amplitude reduction in the cortical component of the primary negative peak (greater than 50%) in SSEP occurred in 6 patients, and an increase in central conduction time (CCT) (greater than 1 ms) occurred in 5 patients. Major EEG changes occurred in 6 patients, 4 of whom also had SSEP changes. Two patients had transient neurologic deficits postoperatively, with both having SSEP changes (amplitude reduction greater than 50%), whereas one had EEG changes. Based on these observations, the relative sensitivity and specificity for EEG and SSEP (amplitude reduction greater than 50%) in detecting postoperative neurologic deficits were 50% and 92% for EEG and 100% and 94% for SSEP, respectively, differences that were not statistically significant. Regarding SSEP, the use of latency change (CCT) as a criterion was associated with a sensitivity of 0% (P = 0.046 from sensitivity of amplitude) and a specificity of 87% (P = 0.17 from specificity of amplitude).(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Update on Bispectral Index monitoring
Johansen, J. W. (2006) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2005.08.004 · Cited by 313
Banoub, M., Tetzlaff, J. E., & Schubert, A. (2003) · Anesthesiology · doi:10.1097/00000542-200309000-00029 · Cited by 299
Romero, L. M., & Remage-Healey, L. (2000) · General and Comparative Endocrinology · doi:10.1006/gcen.2000.7491 · Cited by 259
Metadata
- Authors
- Lam, A. M., Manninen, P. H., Ferguson, G. G., & Nantau, W.
- Venue
- Anesthesiology
- Published
- 1991-07-01
- Volume
- 75
- Issue
- 1
- Pages
- 15-21
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1995718389
- Cited by
- 185
- References
- 0
- FWCI
- 4.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Monitoring Electrophysiologic Function during Carotid Endarterectomy: A Comparison of Somatosensory Evoked Potentials and Conventional Electroencephalogram. https://app.cochat.ai/papers/10.1097/00000542-199107000-00004
- The paper
- Lam, A. M., Manninen, P. H., Ferguson, G. G., & Nantau, W. (1991). Monitoring Electrophysiologic Function during Carotid Endarterectomy: A Comparison of Somatosensory Evoked Potentials and Conventional Electroencephalogram. Anesthesiology. https://doi.org/10.1097/00000542-199107000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.