Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record, with a small difference in title or year; 243 of the 243 references it cites were found in a registry or an index.

Pharmacologic and Physiologic Influences Affecting Sensory Evoked Potentials: Implications for Perioperative Monitoring

Banoub, Mark, Tetzlaff, John E., Schubert, Armin · 2003 · Anesthesiology

Abstract

Received from the Department of General Anesthesiology, The Cleveland Clinic Foundation, Cleveland, Ohio.EVOKED potentials (EPs) are the electrophysiologic responses of the nervous system to sensory or motor stimulation. 1,2Stimulating the nervous system initiates the transmission of neural signals that may be recorded as EPs from various points along the stimulated pathway. Intraoperative monitoring (IOM) of EP has gained popularity because EPs reflect the functional integrity of neural pathways in anesthetized patients undergoing surgical procedures that place nervous system structures in jeopardy. EPs monitored intraoperatively include somatosensory evoked potentials (SSEPs), brainstem auditory evoked potentials (BAEPs; also referred to as auditory brainstem responses), visual evoked potentials (VEPs), and motor evoked potentials. Additional EP modalities include dermatomal sensory evoked potentials, electrocochleography, and electromyography.Intraoperative EP changes may result from surgical injury or ischemia of the specific neural pathway, or they may be due to nonspecific physiologic or pharmacologic influences. Physiologic factors that may influence EPs include temperature, blood pressure, hematocrit, acid–base balance, and oxygen and carbon dioxide tensions. Anesthetic drugs and sedatives are the most common pharmacologic causes of nonspecific EP changes.This review discusses the physiologic and pharmacologic factors (including newer anesthetic agents and adjuncts) that influence sensory evoked potentials (SEPs), focussing on SSEPs, BAEPs, and VEPs. For ease of reference and to allow better comparisons between anesthetic agents, the discussion of anesthetic effects is separated from physiologic effects. The review intends to help clinicians recognize the important confounding perturbations so that intraoperative changes in SEPs can be interpreted optimally. It also aims to guide anesthetic planning so that reliable intraoperative EP monitoring can be accomplished during effective and safe anesthesia.The single cortical sensory evoked response has a low amplitude (1–2 μV) compared with the much larger electroencephalogram waves (50–100 μV). Therefore, the EP wave has to be extracted from concurrent spontaneous electroencephalogram activity by repetitive stimulation and computer-signal averaging techniques. 3The EP waveform consists of a series of peaks and valleys presented as a graph of voltage over time and described in terms of amplitude, latency, and morphology. For IOM, amplitude is commonly measured as the waves’ peak-to-peak voltage difference. Latency is the time from stimulus to the peak of the response. Interpeak latency is the interval between the peaks of interest (fig. 1).Evoked potential waves can have either negative or positive polarity. A negative wave occurring at a latency of approximately 20 ms would be indicated as N-20. Generally, negative waves are shown as upward deflections, while positive waves are shown as downward deflections. Evoked potentials can be of cortical or subcortical origin. Responses recorded by electrodes located within 3–4 cm of the neural generator are termed near-field potentials (e.g. , cortical SSEP waves recorded from scalp electrodes), whereas those recorded from electrodes farther from the neural generator are called far-field potentials (e.g. , BAEP recorded over the vertex). 4,5SEPs are also classified as short latency (< 30 ms), intermediate latency (30–75 ms), or long latency (> 75 ms). 6For the purposes of this review, SEPs are considered recordable when reproducible waveforms are reported. An anesthetic regimen is described as compatible with IOM when it results in consistently recordable waveforms. Reliability of SEPs refers to their ability to detect potentially injurious conditions intraoperatively.The SSEP represents the reproducible electrical activity of cortical and subcortical structures time-locked to a peripheral nerve stimulus. For perioperative applications, electrical impulses are commonly delivered to the median nerve or posterior tibial nerves using needle or surface electrodes. The impulse propagates peripherally (resulting in muscle twitches) and centrally via the peripheral nerve and the dorsal root to the spinal cord. The nerve cell body of the first-order neuron lies in the dorsal root ganglion. Impulses then ascend primarily in the dorsal column fibers of the spinal cord, which synapse (fig. 2) in the lower medulla near the nucleus gracilis and cuneatus, respectively. Axons of the second-order neurons cross the midline at the cervicomedullary junction, from where they regroup to form the medial lemniscus and synapse in the ventroposterior–lateral nucleus of the contralateral thalamus. Third-order neurons from the ventroposterior–lateral leave the thalamus and travel through the posterior limb of the internal capsule as the thalamocortical radiation to synapse in the primary somatosensory cortex in the postcentral gyrus of th

Overview

Integrity signals

Registry

Crossref · 10.1097/00000542-200309000-00029

Cites

243 of 243 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 237 references

Cited by

See all 315

Metadata

Authors
Banoub, M., Tetzlaff, J. E., & Schubert, A.
Affiliations
  • Mercy St. Vincent Medical Center (US)
  • Cleveland Clinic (US)
Venue
Anesthesiology
Published
2003-09-01
Volume
99
Issue
3
Pages
716-737
ISSN
0003-3022 (ISSN-L)
OpenAlex
W1966061837
Cited by
299
References
237
Citations by year
2026: 6 · 2025: 18 · 2024: 16 · 2023: 13 · 2022: 17 · 2021: 14 · 2020: 11 · 2019: 14 · 2018: 8 · 2017: 18 · 2016: 14 · 2015: 10 · 2014: 10 · 2013: 9 · 2012: 14
FWCI
1.58
Type
journal article
Language
en
Open access
closed
Locations
  • Anesthesiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Intraoperative Neuromonitoring and Anesthetic Effects
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Anesthesia and Sedative Agents
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Anesthesia and Pain Management
Keywords
sensory evoked potentials, intraoperative neuromonitoring, somatosensory evoked potentials, auditory brainstem evoked potentials, visual evoked potentials, anesthetic effects, signal averaging, anesthetic agents, sedatives, anesthetic planning, nerve injury detection, temperature, blood pressure, acid-base balance, hematocrit
MeSH terms
Anesthesia, Anesthetics, Animals, Electrophysiology, Evoked Potentials, Auditory, Evoked Potentials, Somatosensory, Evoked Potentials, Visual, Humans, Evoked Potentials, Auditory, Brain Stem, Monitoring, Intraoperative, Anesthetics, Inhalation, Anesthetics, Intravenous

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pharmacologic and Physiologic Influences Affecting Sensory Evoked Potentials: Implications for Perioperative Monitoring. https://app.cochat.ai/papers/10.1097/00000542-200309000-00029
The paper
Banoub, M., Tetzlaff, J. E., & Schubert, A. (2003). Pharmacologic and Physiologic Influences Affecting Sensory Evoked Potentials: Implications for Perioperative Monitoring. Anesthesiology. https://doi.org/10.1097/00000542-200309000-00029

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.