CoChat

Cardiac Output by Transesophageal Echocardiography Using Continuous-wave Doppler across the Aortic Valve

Darmon, Pierre-Louis, Hillel, Zak, Mogtader, Allen, Mindich, Bruce, Thys, Daniel · 1994 · Anesthesiology
Cited by 183

The DOI matches its Crossref record.

Abstract

BACKGROUND: The use of transesophageal echocardiography for the determination of cardiac output (CO) has been limited to date. We assessed the capability of aortic continuous-wave Doppler transesophageal echocardiography to determine CO (DCO) in a transgastric long-axis imaging plane of the heart by comparing DCO to thermodilution CO (TCO). METHODS: DCO was determined in 63 consecutive patients undergoing cardiac surgery. Aortic valve area was obtained from the transverse short-axis view of the valve assuming a triangular shape for the valve orifice. Stroke volume was calculated as the product of velocity-time integral and aortic valve area: stroke volume = velocity-time integral x aortic valve area. DCO was calculated off-line, by multiplying stroke volume with heart rate: DCO = stroke volume x heart rate. RESULTS: The aortic valve orifice was easily imaged in all patients. Excellent-quality continuous-wave Doppler flow profiles were obtained in nearly all (62 of 63). A total of 109 DCO determinations were performed. Mean DCO was 4.35 +/- 1.18 l.min-1 (range 2.02-7.42 l.min-1), and mean TCO was 4.41 +/- 1.17 l.min-1 (range 2.24-8.94 l.min-1). Very high correlation and agreement were found between the two methods: DCO = 0.94 x TCO + 0.19, r = 0.94, SEE (standard error of the estimate) = 0.41 l.min-1; 95% confidence interval = 0.06 +/- 0.83 l.min-1. Relative changes from pre- to postbypass CO (delta) also showed a strong correlation (delta DCO = 0.93 x delta TCO + 5.4%, r = 0.82, SEE = 17.8%). For CO changes greater than 10%, Doppler was in accordance with thermodilution in 43 of 45 measurements. DCO repeatability coefficient was 0.51 l.min-1. CONCLUSIONS: Compared to thermodilution, continuous-wave Doppler measurements of blood flow velocity across the aortic valve in the transesophageal echocardiographic transgastric view allow accurate CO determination.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-199404000-00011

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 183

Metadata

Authors
Darmon, P.-L., Hillel, Z., Mogtader, A., Mindich, B., & Thys, D.
Venue
Anesthesiology
Published
1994-04-01
Volume
80
Issue
4
Pages
796-805
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2076889980
Cited by
183
References
0
FWCI
8.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiac Output by Transesophageal Echocardiography Using Continuous-wave Doppler across the Aortic Valve. https://app.cochat.ai/papers/10.1097/00000542-199404000-00011
The paper
Darmon, P.-L., Hillel, Z., Mogtader, A., Mindich, B., & Thys, D. (1994). Cardiac Output by Transesophageal Echocardiography Using Continuous-wave Doppler across the Aortic Valve. Anesthesiology. https://doi.org/10.1097/00000542-199404000-00011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.