The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Detection of Intraoperative Incidents by Electronic Scanning of Computerized Anesthesia Records: Comparison with Voluntary Reporting
Open accessAbstract
Background: The use of a computerized anesthesia information management system provides an opportunity to scan case records electronically for deviations from specific limits for physiologic variables. Anesthesia department policy may define such deviations as intraoperative incidents and may require anesthesiologists to report their occurrence. The actual incidence of such events is not known. Neither is the level of compliance with voluntary reporting. Methods: Using automated anesthesia record-keeping with long-term storage, physiologic data were recorded every 15 s from 5,454 patients undergoing noncardiothoracic surgery. Recorded measurements of blood pressure, heart rate, arterial oxygen saturation, and temperature were electronically analyzed for deviations from defined limits. The computer system also was used by anesthesiologists to report voluntarily those deviations as intraoperative incidents. For each electronically detected incident: 1) the complete automated anesthesia record was examined by two senior anesthesiologists who, by consensus, eliminated case records with artifact or in which context suggested that the incident was not clinically relevant, and 2) the anesthesia information management system database was checked for voluntary reporting. Results: In 473 automated anesthesia records, 494 incidents were found by electronic scanning of 5,454 automated anesthesia records. Sixty intraoperative incidents were eliminated, 25 due to artifact and 35 due to context. When the remaining 434 intraoperative incidents were checked for voluntary reporting, 18 (4.1%) matching voluntary reports were found. All intraoperative incidents that were reported voluntarily also were detected by electronic scanning. Based on a 10% sample, the sensitivity rate of electronic scanning was 97.2% (35/36), and the specificity rate was 98.4% (427/434). Among 413 cases with electronically detected intraoperative incidents, there were 29 deaths (7.0%), whereas there were only 79 deaths (1.6%) among 5,041 cases without incidents (chi 2 = 58.5, P < 0.001). Conclusions: The use of an anesthesia information management system facilitated analysis of intraoperative physiologic data and identified certain intraoperative incidents with high sensitivity and specificity. A low level of compliance with voluntary reporting of defined intraoperative incidents was found for all anesthesiologists studied. Finally, there was a strong association between intraoperative incidents and in-hospital mortality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physician Reporting Compared with Medical-Record Review to Identify Adverse Medical Events
O'Neil, A. C., Petersen, L. A., Cook, E. F., Bates, D. W., Lee, T. H., & Brennan, T. A. (1993) · Annals of Internal Medicine · doi:10.7326/0003-4819-119-5-199309010-00004 · Cited by 315
Cited by
Emergency Tracheal Intubation: Complications Associated with Repeated Laryngoscopic Attempts
Mort, T. C. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000122825.04923.15 · Cited by 995
Bijker, J. B., van Klei, W. A., Kappen, T. H., van Wolfswinkel, L., Moons, K. G. M., & Kalkman, C. J. (2007) · Anesthesiology · doi:10.1097/01.anes.0000270724.40897.8e · Cited by 710
Murat, I., Constant, I., & Maud'huy, H. (2004) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2004.01167.x · Cited by 493
An Exploratory Look at Pediatric Cochlear Implantation: Is Earliest Always Best?
Holt, R. F., & Svirsky, M. A. (2008) · Ear & Hearing · doi:10.1097/aud.0b013e31816c409f · Cited by 279
Mort, T. C. (2004) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2004.01.007 · Cited by 276
Metadata
- Authors
- Sanborn, K. V., Castro, J., Kuroda, M., & Thys, D. M.
- Venue
- Anesthesiology
- Published
- 1996-11-01
- Volume
- 85
- Issue
- 5
- Pages
- 977-987
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2032882478
- Cited by
- 176
- References
- 1
- FWCI
- 7.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Intraoperative Incidents by Electronic Scanning of Computerized Anesthesia Records: Comparison with Voluntary Reporting. https://app.cochat.ai/papers/10.1097/00000542-199611000-00004
- The paper
- Sanborn, K. V., Castro, J., Kuroda, M., & Thys, D. M. (1996). Detection of Intraoperative Incidents by Electronic Scanning of Computerized Anesthesia Records: Comparison with Voluntary Reporting. Anesthesiology. https://doi.org/10.1097/00000542-199611000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.