Volume Kinetics of Ringer Solution, Dextran 70, and Hypertonic Saline in Male Volunteers
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Background: A knowledge of the distribution of different fluids given by intravenous infusion is basic to the understanding of the effects of fluid therapy. Therefore, a mathematical model was tested to analyze the volume kinetics of three types of fluids. Methods: The authors infused 25 ml/kg of Ringer acetate solution, 5 ml/kg of 6% dextran 70 in 0.9% NaCl, and 3 ml/kg of 7.5% NaCl over 30 min in 8 male volunteers aged from 25 to 36 years (mean, 31 years) and measured the changes in total hemoglobin, serum albumin, and total blood water over time. The changes were expressed as fractioned dilution and then plotted against time. The curves were fitted to a one-volume and a two-volume model, which allowed an estimation of the size of the body fluid space expanded by the fluid (V) and the elimination rate constant (k(r) to be made. Results: The changes in blood water concentration indicated a mean size of V of 5.9 1 (+/- 0.8, SEM) for Ringer's solution, 2.6 (+/- 0.3) 1 for dextran, and 1.2 (+/- 0.1) 1 for hypertonic saline. The corresponding values of k(r) were 94 (+/- 42), 12 (+/- 6), and 30 (+/- 4) ml/min, respectively. Blood hemoglobin indicated a degree of dilution similar to that indicated by blood water. Serum albumin indicated a more pronounced dilution, which resulted in a larger expandable volume and a greater mean square error for the curvefitting. The larger volume obtained for serum albumin can probably be explained by a loss of intravascular albumin into the tissues along with the infused fluid. Conclusions: The distribution of intravenous fluids can be analyzed by a kinetic model adapted for fluid spaces, but slightly different results are obtained, depending on the marker used to indicate dilution of the primary fluid space. Analysis and simulation of plasma volume expansion by this model is a tool that can help the anesthetist to better plan fluid therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1962) · PubMed · Cited by 2,094
Fitting curves to data using nonlinear regression: a practical and nonmathematical review
Motulsky, H. J., & Ransnas, L. A. (1987) · The FASEB Journal · doi:10.1096/fasebj.1.5.3315805 · Cited by 1,327
Interstitial-lymphatic mechanisms in the control of extracellular fluid volume
Aukland, K., & Reed, R. K. (1993) · Physiological Reviews · doi:10.1152/physrev.1993.73.1.1 · Cited by 934
Plasma volume changes after infusion of various plasma expanders
Lamke, L.-O., & Liljedahl, S.-O. (1976) · Resuscitation · doi:10.1016/0300-9572(76)90029-0 · Cited by 208
Moore, F. D., Dagher, F. J., Boyden, C. M., Lee, V. C. J., & Lyons, J. H. (1966) · Annals of Surgery · doi:10.1097/00000658-196604000-00001 · Cited by 111
Hint, H. C. (1968) · PubMed · Cited by 103
Modelling the volume of expandable body fluid spaces during i.v. fluid therapy
Ståhle, L., Nilsson, A. C., & Hahn, R. G. (1997) · British Journal of Anaesthesia · doi:10.1093/bja/78.2.138 · Cited by 63
Self-citation
Cited by
(Ab)normal saline and physiological Hartmann's solution: a randomized double-blind crossover study
REID, F., LOBO, D. N., WILLIAMS, R. N., ROWLANDS, B. J., & ALLISON, S. P. (2003) · Clinical Science · doi:10.1042/cs1040017 · Cited by 284
Volume Kinetics for Infusion Fluids
Hahn, R. G., & Warner, D. S. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181dcd88f · Cited by 210
“The size of Vt is 6–8 l in adult males weighing 70–80 kg and, therefore, smaller than the expected size of the interstitial fluid space.(3,10,11) In contrast to tracer ions such as bromide, however, volume kinetics indicates only the body fluid spaces that can be expanded, and this is not possible in certain body regi…”
BackgroundSelf-citationEpidural Anesthesia, Hypotension, and Changes in Intravascular Volume
Holte, K., Foss, N. B., Svensén, C., Lund, C., Madsen, J. L., & Kehlet, H. (2004) · Anesthesiology · doi:10.1097/00000542-200402000-00016 · Cited by 185
“The distribution of the fluid given by infusion of HES was analyzed using a one-volume kinetic model.(6) In this model, the fluid is given at a rate ki and is distributed in an expandable space having a volume (v), which the body strives to maintain at a target volume (V).”
BackgroundMethodResultHow perioperative fluid balance influences postoperative outcomes
Lobo, D. N., Macafee, D. A. L., & Allison, S. P. (2006) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2006.03.004 · Cited by 164
Circadian changes in the sweating-to-vasoconstriction interthreshold range
Tayefeh, F., Plattner, O., Sessler, D. I., Ikeda, T., & Marder, D. (1998) · Pfl�gers Archiv European Journal of Physiology · doi:10.1007/s004240050530 · Cited by 79
“However, most of the administered lactate-Ringer’s solution rapidly diffuses into the extracellular space, leaving relatively little remaining within the blood stream [ 34 ].”
Background
Metadata
- Authors
- Svensen, C., & Hahn, R. G.
- Venue
- Anesthesiology
- Published
- 1997-08-01
- Volume
- 87
- Issue
- 2
- Pages
- 204-212
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2086340914
- Cited by
- 164
- References
- 7
- FWCI
- 5.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.