Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 703

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

The Intubation Difficulty Scale (IDS): Proposal and Evaluation of a New Score Characterizing the Complexity of Endotracheal Intubation

Open access
Adnet, Frederic, Borron, Stephen W., Racine, Stephane X., Clemessy, Jean-Luc, Fournier, Jean-Luc, Plaisance, Patrick, Lapandry, Claude·1997·Anesthesiology

Abstract

Background: A quantitative scale of intubation difficulty would be useful for objectively comparing the complexity of endotracheal intubations. The authors have developed a quantitative score that can be used to evaluate intubating conditions and techniques with the aim of determining the relative values of predictive factors of intubation difficulty and of the techniques used to decrease such difficulties. Methods: An Intubation Difficulty Scale (IDS) was developed, based on parameters known to be associated with difficult intubation. It was then evaluated prospectively in a group of 311 consecutive prehospital intubations and 315 intubations in an operating room. In the operating room, the IDS was compared with two other parameters: the time to completion of intubation and the visual analog scale (VAS). Time was measured by an independent observer. Operators in both groups completed a checklist regarding the conditions of intubation. Results: There is a good correlation between the IDS scale and the VAS assessment of difficulty and time to completion of intubation. VAS and time to completion have a significant but lesser correlation to each other. Comparison of IDS with operator-assessed subjective categorical impression of difficulty by Kruskall-Wallis was statistically significant. Conclusions: The IDS correlates with but is less subjective than the VAS and categorical classification. IDS correlates with time to intubation, but it offers details regarding the difficulty encountered that time alone does not. This score may not only aid in evaluation of factors linked to difficult intubations, but it may provide a uniform approach to comparing studies related to this subject.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-199712000-00005

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 703

Metadata

Authors
Adnet, F., Borron, S. W., Racine, S. X., Clemessy, J.-L., Fournier, J.-L., Plaisance, P., & Lapandry, C.
Venue
Anesthesiology
Published
1997-12-01
Volume
87
Issue
6
Pages
1290-1297
ISSN
0003-3022 (ISSN-L)
OpenAlex
W1973132844
Cited by
703
References
8
FWCI
12.40
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Intubation Difficulty Scale (IDS): Proposal and Evaluation of a New Score Characterizing the Complexity of Endotracheal Intubation. https://app.cochat.ai/papers/10.1097/00000542-199712000-00005
The paper
Adnet, F., Borron, S. W., Racine, S. X., Clemessy, J.-L., Fournier, J.-L., Plaisance, P., & Lapandry, C. (1997). The Intubation Difficulty Scale (IDS): Proposal and Evaluation of a New Score Characterizing the Complexity of Endotracheal Intubation. Anesthesiology. https://doi.org/10.1097/00000542-199712000-00005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.