Adverse Respiratory Events in Anesthesia: A Closed Claims Analysis
Open accessAbstract
Adverse outcomes associated with respiratory events constitute the single largest class of injury in the American Society of Anesthesiology Closed Claims Study (522 of 1541 cases; 34%). Death or brain damage occurred in 85% of cases. The median cost of settlement or jury award was +200,000. Most outcomes (72%) were considered preventable with better monitoring. Three mechanisms of injury accounted for three-fourths of the adverse respiratory events: inadequate ventilation (196; 38%), esophageal intubation (94; 18%), and difficult tracheal intubation (87; 17%). Inadequate ventilation was used to describe claims in which it was evident that insufficient gas exchange had produced the adverse outcome, but it was not possible to identify the exact cause. This group was characterized by the highest proportion of cases in which care was considered substandard (90%). The esophageal intubation group was notable for a recurring diagnostic failure: in 48% of cases where auscultation of breath sounds was performed and documented, this test led to the erroneous conclusion that the endotracheal tube was correctly located in the trachea. Claims for difficult tracheal intubation were distinguished by a comparatively small proportion of cases (36%) in which the outcome was considered preventable with better monitoring. A better understanding of respiratory risks may require investigative protocols that initiate data collection immediately upon the recognition of a critical incident or adverse outcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cook, T. M., Woodall, N., & Frerk, C. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer058 · Cited by 2,415
Cook, T. M., Woodall, N., Harper, J., & Benger, J. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer059 · Cited by 1,065
Prediction of Difficult Mask Ventilation
Langeron, O., Masso, E., Huraux, C., Guggiari, M., Bianchi, A., Coriat, P., & Riou, B. (2000) · Anesthesiology · doi:10.1097/00000542-200005000-00009 · Cited by 915
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., Schofield-Robinson, O. J., & Smith, A. F. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex228 · Cited by 359
Video‐laryngoscopes in the adult airway management: a topical review of the literature
NIFOROPOULOU, P., PANTAZOPOULOS, I., DEMESTIHA, T., KOUDOUNA, E., & XANTHOS, T. (2010) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2010.02285.x · Cited by 316
Metadata
- Authors
- Caplan, R. A., Posner, K. L., Ward, R. J., & Cheney, F. W.
- Venue
- Anesthesiology
- Published
- 1990-05-01
- Volume
- 72
- Issue
- 5
- Pages
- 828-833
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1996859235
- Cited by
- 1,060
- References
- 0
- FWCI
- 39.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adverse Respiratory Events in Anesthesia: A Closed Claims Analysis. https://app.cochat.ai/papers/10.1097/00000542-199005000-00010
- The paper
- Caplan, R. A., Posner, K. L., Ward, R. J., & Cheney, F. W. (1990). Adverse Respiratory Events in Anesthesia: A Closed Claims Analysis. Anesthesiology. https://doi.org/10.1097/00000542-199005000-00010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.