Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 209

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

The Sensitivity and Specificity of the Caffeine-Halothane Contracture Test: A Report from the North American Malignant Hyperthermia Registry

Open access
Allen, Gregory C., Larach, Marilyn Green, Kunselman, Allen R.·1998·Anesthesiology

Abstract

Background: The caffeine-halothane contracture test (CHCT) is the only recognized laboratory test to diagnose malignant hyperthermia (MH). The authors report the results of their analysis of pooled data from the North American Malignant Hyperthermia Registry database to determine the sensitivity and specificity of the CHCT. Methods: The MH Clinical Grading Scale was used to identify 32 case subjects who were "almost certain" to be MH susceptible based on clinical criteria alone. Their CHCT results were compared with those of a group of 120 control subjects considered to be at low risk for MH. Diagnostic thresholds of the CHCT were adjusted, and its component tests were combined to generate receiver operating characteristic curves. The maximal Youden index for each component test was chosen as the diagnostic threshold indicative of MH susceptibility. Results: The highest sensitivity (97%; 95% CI, 84-100%) was achieved with a two-component test with thresholds of > or = 0.5 g contracture for 3% halothane, > or = 0.3 g contracture at 2 mM caffeine, or both, considered positive for MH. The test specificity was 78% (95% CI, 69-85%). The addition of other CHCT component tests did not improve CHCT sensitivity or specificity. Conclusion: The CHCT achieves high sensitivity and acceptable specificity as a clinical laboratory diagnostic test when it is performed according to published standards. However, it cannot be used as a screening test because of the low prevalence of MH in the general population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-199803000-00006

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 209

Metadata

Authors
Allen, G. C., Larach, M. G., & Kunselman, A. R.
Venue
Anesthesiology
Published
1998-03-01
Volume
88
Issue
3
Pages
579-588
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2087955851
Cited by
209
References
1
FWCI
13.40
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Sensitivity and Specificity of the Caffeine-Halothane Contracture Test: A Report from the North American Malignant Hyperthermia Registry. https://app.cochat.ai/papers/10.1097/00000542-199803000-00006
The paper
Allen, G. C., Larach, M. G., & Kunselman, A. R. (1998). The Sensitivity and Specificity of the Caffeine-Halothane Contracture Test: A Report from the North American Malignant Hyperthermia Registry. Anesthesiology. https://doi.org/10.1097/00000542-199803000-00006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.