The DOI matches its Crossref record.
Bispectral EEG Index during Nitrous Oxide Administration
Abstract
Background: Nitrous oxide (N2O) is a commonly used sedative for painful diagnostic procedures and dental work. The authors sought to characterize the effects of N2O on quantitative electroencephalographic (EEG) variables including the bispectral index (BIS), a quantitative parameter developed to correlate with the level of sedation induced by a variety of agents. Methods: Healthy young adult volunteers (n = 13) were given a randomized sequence of N2O/O2 combinations via face mask. Five concentrations of N2O (10, 20, 30, 40, and 50% atm) were administered for 15 min (20 min for the first step). EEG was recorded from bilateral frontal poles continuously. At the end of each exposure, level of sedation was assessed using primarily the Observer Assessment of Alertness/Sedation (OAA/S) scale. Results: One subject withdrew from the study because of emesis at 50% N2O. N2O (50%) increased theta, beta, 40-50 Hz, and 70-110 Hz band powers. BIS and spectral edge frequency during 50% N2O/O2 did not differ significantly from baseline values. Abrupt decreases from higher to lower concentrations frequently evoked a profound, transient slowing of activity. No significant change in OAA/S was detected during the study. Conclusions: Although the spectral content of the EEG changed during N2O administration, reflecting some pharmacologic effect, the subjects remained cooperative and responsive throughout, and therefore N2O can only be considered a weak sedative at the tested concentrations. Despite changes in the lower and higher frequency ranges of EEG activity, the BIS did not change, which is consistent with its design objective as a specific measure of hypnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Development and Clinical Application of Electroencephalographic Bispectrum Monitoring
Johansen, J. W., Sebel, P. S., & Fisher, D. M. (2000) · Anesthesiology · doi:10.1097/00000542-200011000-00029 · Cited by 599
Dahaba, A. A. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000167269.62966.af · Cited by 379
Preoperative Anxiety and Intraoperative Anesthetic Requirements
Maranets, I., & Kain, Z. N. (1999) · Anesthesia & Analgesia · doi:10.1097/00000539-199912000-00003 · Cited by 327
Update on Bispectral Index monitoring
Johansen, J. W. (2006) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2005.08.004 · Cited by 313
Romero, L. M., & Remage-Healey, L. (2000) · General and Comparative Endocrinology · doi:10.1006/gcen.2000.7491 · Cited by 259
Metadata
- Authors
- Rampil, I. J., Kim, J.-S., Lenhardt, R., Negishi, C., & Sessler, D. I.
- Venue
- Anesthesiology
- Published
- 1998-09-01
- Volume
- 89
- Issue
- 3
- Pages
- 671-677.
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2092812121
- Cited by
- 221
- References
- 0
- FWCI
- 13.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bispectral EEG Index during Nitrous Oxide Administration. https://app.cochat.ai/papers/10.1097/00000542-199809000-00017
- The paper
- Rampil, I. J., Kim, J.-S., Lenhardt, R., Negishi, C., & Sessler, D. I. (1998). Bispectral EEG Index during Nitrous Oxide Administration. Anesthesiology. https://doi.org/10.1097/00000542-199809000-00017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.