The Effects of Body Mass on Lung Volumes, Respiratory Mechanics, and Gas Exchange During General Anesthesia
Abstract
UNLABELLED: We investigated the effects of body mass index (BMI) on functional residual capacity (FRC), respiratory mechanics (compliance and resistance), gas exchange, and the inspiratory mechanical work done per liter of ventilation during general anesthesia. We used the esophageal balloon technique, together with rapid airway occlusion during constant inspiratory flow, to partition the mechanics of the respiratory system into its pulmonary and chest wall components. FRC was measured by using the helium dilution technique. We studied 24 consecutive and unselected patients during general anesthesia, before surgical intervention, in the supine position (8 normal subjects with a BMI < or = 25 kg/m2, 8 moderately obese patients with a BMI >25 kg/m2 and <40 kg/m2, and 8 morbidly obese patients with a BMI > or = 40 kg/m2). We found that, with increasing BMI: 1. FRC decreased exponentially (r = 0.86; P < 0.01) 2. the compliance of the total respiratory system and of the lung decreased exponentially (r = 0.86; P < 0.01 and r = 0.81; P < 0.01, respectively), whereas the compliance of the chest wall was only minimally affected (r = 0.45; P < 0.05) 3. the resistance of the total respiratory system and of the lung increased (r = 0.81; P < 0.01 and r = 0.84; P < 0.01, respectively), whereas the chest wall resistance was unaffected (r = 0.06; P = not significant) 4. the oxygenation index (PaO2/PAO2) decreased exponentially (r = 0.81; P < 0.01) and was correlated with FRC (r = 0.62; P < 0.01), whereas PaCO2 was unaffected (r = 0.06; P = not significant) 5. the work of breathing of the total respiratory system increased, mainly due to the lung component (r = 0.88; P < 0.01 and r = 0.81; P < 0.01, respectively). In conclusion, BMI is an important determinant of lung volumes, respiratory mechanics, and oxygenation during general anesthesia with patients in the supine position. IMPLICATIONS: The aim of this study was to investigate the influence of body mass on lung volumes, respiratory mechanics, and gas exchange during general anesthesia.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Obese patients consistently have a reduced expiratory reserve volume (or FRC) proportional to the magnitude of obesity.
“Obese patients consistently have a reduced expiratory reserve volume (or FRC) proportional to the magnitude of obesity.99,108,110,113–120”
From Pathogenesis of hyperinflation in chronic obstructive pulmonary disease (2014) · cites this paper as [118]
Cited by
Sorted by citations
The effect of obesity on lung function
Dixon, A. E., & Peters, U. (2018) · Expert Review of Respiratory Medicine · doi:10.1080/17476348.2018.1506331 · Cited by 889 · see citing works
The Impact of Obesity on Oxygen Desaturation during Sleep-disordered Breathing
Peppard, P. E., Ward, N. R., & Morrell, M. J. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200905-0773oc · Cited by 194 · see citing works
Pathogenesis of hyperinflation in chronic obstructive pulmonary disease
Saey, Gagnon, P., Guenette, J., Langer, D., Laviolette, L., Mainguy, V., Maltais, F., & Ribeiro, F. (2014) · International Journal of Chronic Obstructive Pulmonary Disease · doi:10.2147/copd.s38934 · Cited by 180 · see citing works
Ora, J., Laveneziana, P., Ofir, D., Deesomchok, A., Webb, K. A., & O'Donnell, D. E. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200904-0530oc · Cited by 139 · see citing works
Effect of obesity on respiratory mechanics during rest and exercise in COPD
Ora, J., Laveneziana, P., Wadell, K., Preston, M., Webb, K. A., & O'Donnell, D. E. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01131.2010 · Cited by 101 · see citing works
Blechert, J., Wilhelm, F. H., Meuret, A. E., Wilhelm, E. M., & Roth, W. T. (2010) · Biological Psychology · doi:10.1016/j.biopsycho.2010.01.002 · Cited by 43 · see citing works
Positive-end expiratory pressure titration and transpulmonary pressure: the EPVENT 2 trial
Turbil, E., Galerneau, L. M., Terzi, N., Schwebel, C., Argaud, L., & Guérin, C. (2019) · Journal of Thoracic Disease · doi:10.21037/jtd.2019.06.34 · Cited by 8 · see citing works
Rybka-Fraczek, A., Orzolek, I., & Dabrowska, M. (2026) · The Journal of Allergy and Clinical Immunology: In Practice · doi:10.1016/j.jaip.2025.10.014 · Cited by 5 · see citing works
- Authors
- Pelosi, P., Croci, M., Ravagnan, I., Tredici, S., Pedoto, A., Lissoni, A., & Gattinoni, L.
- Affiliations
- University of Milan (IT)
- Corresponding author
- Pelosi, Paolo
- Venue
- Anesthesia & Analgesia
- Published
- 1998-09
- Volume
- 87
- Issue
- 3
- Pages
- 654-660
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W4233094824
- Cited by
- 655
- References
- 0
- Citations by year
- 2026: 25 · 2025: 27 · 2024: 22 · 2023: 25 · 2022: 34 · 2021: 25 · 2020: 41 · 2019: 28 · 2018: 31 · 2017: 24 · 2016: 29 · 2015: 28 · 2014: 31 · 2013: 25 · 2012: 28
- FWCI
- 6.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Anesthesia & Analgesia (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Airway Management and Intubation Techniques
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Anesthesia and Sedative Agents
- Keywords
- body mass index, obesity, morbid obesity, general anesthesia, functional residual capacity, respiratory mechanics, lung compliance, airway resistance, chest wall compliance, work of breathing, oxygenation, gas exchange, supine position, helium dilution, airway occlusion, PaCO2, lung volume, chest wall
- MeSH terms
- Adult, Aged, Airway Resistance, Anesthesia, General, Female, Functional Residual Capacity, Humans, Lung Volume Measurements, Male, Middle Aged, Obesity, Morbid, Oxygen, Pulmonary Gas Exchange, Tidal Volume, Work of Breathing, Respiratory Mechanics, Body Mass Index
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review