Electroencephalogram Approximate Entropy Correctly Classifies the Occurrence of Burst Suppression Pattern as Increasing Anesthetic Drug Effect
Open accessThe DOI matches its Crossref record.
Abstract
Background: Approximate entropy, a measure of signal complexity and regularity, quantifies electroencephalogram changes during anesthesia. With increasing doses of anesthetics, burst-suppression patterns occur. Because of the high-frequency bursts, spectrally based parameters such as median electroencephalogram frequency and spectral edge frequency 95 do not decrease, incorrectly suggesting lightening of anesthesia. The authors investigated whether the approximate entropy algorithm correctly classifies the occurrence of burst suppression as deepening of anesthesia. Methods: Eleven female patients scheduled for elective major surgery were studied. After propofol induction, anesthesia was maintained with isoflurane only. Before surgery, the end-tidal isoflurane concentration was varied between 0.6 and 1.3 minimum alveolar concentration. The raw electroencephalogram was continuously recorded and sampled at 128 Hz. Approximate entropy, electroencephalogram median frequency, spectral edge frequency 95, burst-suppression ratio, and burst-compensated spectral edge frequency 95 were calculated offline from 8-s epochs. The relation between burst-suppression ratio and approximate entropy, electroencephalogram median frequency, spectral edge frequency 95, and burst-compensated spectral edge frequency 95 was analyzed using Pearson correlation coefficient. Results: Higher isoflurane concentrations were associated with higher burst-suppression ratios. Electroencephalogram median frequency (r = 0.34) and spectral edge frequency 95 (r = 0.29) increased, approximate entropy (r = -0.94) and burst-compensated spectral edge frequency 95 (r = -0.88) decreased with increasing burst-suppression ratio. Conclusion: Electroencephalogram approximate entropy, but not electroencephalogram median frequency or spectral edge frequency 95 without burst compensation, correctly classifies the occurrence of burst-suppression pattern as increasing anesthetic drug effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nonlinear dynamical analysis of EEG and MEG: Review of an emerging field
Stam, C. J. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.06.011 · Cited by 1,417
Complex systems and the technology of variability analysis
Seely, A. J., & Macklem, P. T. (2004) · Critical Care · doi:10.1186/cc2948 · Cited by 447
Assessing Serial Irregularity and Its Implications for Health
PINCUS, S. M. (2001) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2001.tb02755.x · Cited by 401
Schartner, M., Seth, A., Noirhomme, Q., Boly, M., Bruno, M.-A., Laureys, S., & Barrett, A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0133532 · Cited by 287
“In support of this, simple randomness measures applicable to a single time series, such as approximate entropy [52] and permutation entropy [31], have been found to decrease during anaesthesia and sleep [27, 28, 32, 34].”
MethodPredictability analysis of absence seizures with permutation entropy
Li, X., Ouyang, G., & Richards, D. A. (2007) · Epilepsy Research · doi:10.1016/j.eplepsyres.2007.08.002 · Cited by 290
Abásolo, D., Hornero, R., Espino, P., Poza, J., Sánchez, C. I., & de la Rosa, R. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.04.001 · Cited by 247
“Although there are many other entropy estimators, several properties of ApEn facilitate its utility for empirical time series analysis of the sort of EEGs: ApEn is nearly unaffected by noise below a de facto specified filter level (r), it can be applied to time series of 50 or more points with good reproducibility; it…”
MethodInfluentialFriedman, E. B., Sun, Y., Moore, J. T., Hung, H.-T., Meng, Q. C., Perera, P., Joiner, W. J., Thomas, S. A., Eckenhoff, R. G., Sehgal, A., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0011903 · Cited by 218
Optimal classification of epileptic seizures in EEG using wavelet analysis and genetic algorithm
Ocak, H. (2008) · Signal Processing · doi:10.1016/j.sigpro.2008.01.026 · Cited by 179
Irregularity, volatility, risk, and financial market time series
Pincus, S., & Kalman, R. E. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0405168101 · Cited by 178
Traumatic Brain Injury Detection Using Electrophysiological Methods
Rapp, P. E., Keyser, D. O., Albano, A., Hernandez, R., Gibson, D. B., Zambon, R. A., Hairston, W. D., Hughes, J. D., Krystal, A., & Nichols, A. S. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00011 · Cited by 173
“Approximate entropy and sample entropy have been used to quantify EEG records (Bruhn et al., 2000; Abásolo et al., 2005; Sabeti et al., 2009; Yuan et al., 2011; Yun et al., 2012), heart interbeat interval sequences (Pincus and Goldberger, 1994; Ho et al.”
MethodNonlinear dynamical analysis of sleep electroencephalography using fractal and entropy approaches
Ma, Y., Shi, W., Peng, C.-K., & Yang, A. C. (2018) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2017.01.003 · Cited by 172
Metadata
- Authors
- Bruhn, J., Röpcke, H., Rehberg, B., Bouillon, T., & Hoeft, A.
- Venue
- Anesthesiology
- Published
- 2000-10-01
- Volume
- 93
- Issue
- 4
- Pages
- 981-985
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1998850687
- Cited by
- 161
- References
- 0
- FWCI
- 4.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.