Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.

Complexity of Multi-Dimensional Spontaneous EEG Decreases during Propofol Induced General Anaesthesia

Open access
Schartner, Michael, Seth, Anil, Noirhomme, Quentin, Boly, Melanie, Bruno, Marie-Aurelie, Laureys, Steven, Barrett, Adam · 2015 · PLOS ONE

Abstract

Emerging neural theories of consciousness suggest a correlation between a specific type of neural dynamical complexity and the level of consciousness: When awake and aware, causal interactions between brain regions are both integrated (all regions are to a certain extent connected) and differentiated (there is inhomogeneity and variety in the interactions). In support of this, recent work by Casali et al (2013) has shown that Lempel-Ziv complexity correlates strongly with conscious level, when computed on the EEG response to transcranial magnetic stimulation. Here we investigated complexity of spontaneous high-density EEG data during propofol-induced general anaesthesia. We consider three distinct measures: (i) Lempel-Ziv complexity, which is derived from how compressible the data are; (ii) amplitude coalition entropy, which measures the variability in the constitution of the set of active channels; and (iii) the novel synchrony coalition entropy (SCE), which measures the variability in the constitution of the set of synchronous channels. After some simulations on Kuramoto oscillator models which demonstrate that these measures capture distinct 'flavours' of complexity, we show that there is a robustly measurable decrease in the complexity of spontaneous EEG during general anaesthesia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0133532

Cites

54 of 54 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig 1 Two 10sec EEG segments from 25 channels. The segment in the left panel is during wakeful rest (WR) and the segment in the right panel is during propofol-induced loss of consciousness (LOC); both segments are shown after pre-processing. The voltage scale is the same for both conditions and the maximal fluctuation shown is approximately 0.1mV (for more data details, see [16, 38]). The recordings for LOC display visibly stronger slow waves (low-frequency components) as compared to those for WR.
Fig 1 Two 10sec EEG segments from 25 channels. The segment in the left panel is during wakeful rest (WR) and the segment in the right panel is during propofol-induced loss of consciousness (LOC); both segments are shown after pre-processing. The voltage scale is the same for both conditions and the maximal fluctuation shown is approximately 0.1mV (for more data details, see [16, 38]). The recordings for LOC display visibly stronger slow waves (low-frequency components) as compared to those for WR.CC BY · PubMed Central
Fig 2 Channel selection from the high density (256 electrodes) EEG. The electrode layout is from manufacturer EGI [40]. The homogeneously distributed channel selection is shown for: a) analyses across the whole scalp; b) analyses restricted to a certain lobe. Chosen channels are indicated as black stars. See text for details.
Fig 2 Channel selection from the high density (256 electrodes) EEG. The electrode layout is from manufacturer EGI [40]. The homogeneously distributed channel selection is shown for: a) analyses across the whole scalp; b) analyses restricted to a certain lobe. Chosen channels are indicated as black stars. See text for details.CC BY · PubMed Central
Fig 3 Schematic of the computation of Lempel-Ziv complexity LZc. a) x i is the activity of the i th EEG electrode, i.e. the i th channel, and a i is the (Hilbert) amplitude of x i. b) b i is binarized a i, using the mean activity of a i as binarisation threshold. c) After binarisation of all n channels, successive n × 1 dimensional observations are concatenated to obtain one binary sequence s in which patterns are searched and listed into a dictionary of binary words via a Lempel-Ziv algorithm. d) Lempel-Ziv complexity LZc is proportional to the size of this dictionary.
Fig 3 Schematic of the computation of Lempel-Ziv complexity LZc. a) x i is the activity of the i th EEG electrode, i.e. the i th channel, and a i is the (Hilbert) amplitude of x i. b) b i is binarized a i, using the mean activity of a i as binarisation threshold. c) After binarisation of all n channels, successive n × 1 dimensional observations are concatenated to obtain one binary sequence s in which patterns are searched and listed into a dictionary of binary words via a Lempel-Ziv algorithm. d) Lempel-Ziv complexity LZc is proportional to the size of this dictionary.CC BY · PubMed Central
Fig 4 Schematic of the computation of SCE. a) Two time series. b) The analytic signals of these two, being complex signals with the real part being the original signal and the imaginary part being the Hilbert transform of the signal. c) A synchrony time series is created for this pair of signals, being 1 at time t if the phases of the complex values of the analytic signals have similar magnitude at this time t. d) SCE(i) with respect to channel i is the entropy over columns (n × 1 synchronies) of the matrix Ψi containing all n synchrony time series for channel i. The overall SCE is then the mean value of the SCE(i) across channels.
Fig 4 Schematic of the computation of SCE. a) Two time series. b) The analytic signals of these two, being complex signals with the real part being the original signal and the imaginary part being the Hilbert transform of the signal. c) A synchrony time series is created for this pair of signals, being 1 at time t if the phases of the complex values of the analytic signals have similar magnitude at this time t. d) SCE(i) with respect to channel i is the entropy over columns (n × 1 synchronies) of the matrix Ψi containing all n synchrony time series for channel i. The overall SCE is then the mean value of the SCE(i) across channels.CC BY · PubMed Central
Fig 5 Complexity measures for increasingly regular activation/synchrony matrices. Given a random binary matrix of activations (for ACE and LZc) or synchronies (for SCE), with increasing number of duplicated channels, the complexity measures monotonically decrease with the number of equal channels. See text for details.
Fig 5 Complexity measures for increasingly regular activation/synchrony matrices. Given a random binary matrix of activations (for ACE and LZc) or synchronies (for SCE), with increasing number of duplicated channels, the complexity measures monotonically decrease with the number of equal channels. See text for details.CC BY · PubMed Central
Fig 6 LZc, ACE and SCE for Kuramoto model. The data were obtained by varying phase-lags for inter-community interactions. A small value of β ext corresponds to a large phase lag and leads to little inter-community synchrony (as measured by phase synchrony, PhaseSync—indicated as green discs, see text for its computation) whereas larger values of β ext correspond to smaller phase lags and lead to greater inter-community synchrony. See main text for details. LZc and ACE show similar dependence on β ext whereas SCE peaks where the former two have a minimum.
Fig 6 LZc, ACE and SCE for Kuramoto model. The data were obtained by varying phase-lags for inter-community interactions. A small value of β ext corresponds to a large phase lag and leads to little inter-community synchrony (as measured by phase synchrony, PhaseSync—indicated as green discs, see text for its computation) whereas larger values of β ext correspond to smaller phase lags and lead to greater inter-community synchrony. See main text for details. LZc and ACE show similar dependence on β ext whereas SCE peaks where the former two have a minimum.CC BY · PubMed Central
Fig 7 LZc, SCE and ACE computed as averages over multiple 10sec segments of EEG of the 7 subjects before and during anaesthesia. States shown are wakeful rest (WR) before propofol, mild sedation (MS), LOC and wakeful rest emerging from propofol sedation (WRa, not shown for single subject results). Measures are computed across 25 channels spread evenly across the whole cortex. The measures score highest for shuffled WR data, and consistently across subjects higher for WR as opposed to LOC. Error bars indicate standard error across segments, cyan horizontal lines are example thresholds for each of the measures, separating WR from LOC for all 7 subjects. For each single subject plot, the mean and standard error across its 7 values per state is displayed in the narrow plot to its right, with the title ‘mean’. For these mean values across subjects, significant differences between state pairs are shown by a double asterisk if p < 0.01 and a single asterisk if p < 0.05 (Wilcoxon rank sum test, FDR corrected for multiple comparison). See Table 1 for effect size comparison.
Fig 7 LZc, SCE and ACE computed as averages over multiple 10sec segments of EEG of the 7 subjects before and during anaesthesia. States shown are wakeful rest (WR) before propofol, mild sedation (MS), LOC and wakeful rest emerging from propofol sedation (WRa, not shown for single subject results). Measures are computed across 25 channels spread evenly across the whole cortex. The measures score highest for shuffled WR data, and consistently across subjects higher for WR as opposed to LOC. Error bars indicate standard error across segments, cyan horizontal lines are example thresholds for each of the measures, separating WR from LOC for all 7 subjects. For each single subject plot, the mean and standard error across its 7 values per state is displayed in the narrow plot to its right, with the title ‘mean’. For these mean values across subjects, significant differences between state pairs are shown by a double asterisk if p < 0.01 and a single asterisk if p < 0.05 (Wilcoxon rank sum test, FDR corrected for multiple comparison). See Table 1 for effect size comparison.CC BY · PubMed Central
Fig 8 Discriminative power across subjects of nine measures, as measured by area under the ROC curve (AROC). Each symbol represents a state pair as indicated. The AROC is computed from the mean scores for the 7 subjects, obtained from the broadband signal from 25 electrodes from the whole cortex. The closer the AROC is to 0 or 1, the better the measure is at discriminating the given state-pair, close to 1 signifying that the measure tends to be greater for the more conscious state and close to 0 signifying that the measure tends to be greater for the less conscious state. When the AROC is 0.5 there is no discriminative power; hit rate equals false alarm rate for all classification thresholds. LZc, ACE and SCE have nearly maximal discriminative power for state pairs LOC/MS and LOC/WR. The measure sumCov fails to discriminate LOC/MS yet has strong (inverse) discriminative power for LOC/WR and MS/WR. Normalized delta band power discriminates LOC/WR and LOC/MS strongly yet MS/WR poorly.
Fig 8 Discriminative power across subjects of nine measures, as measured by area under the ROC curve (AROC). Each symbol represents a state pair as indicated. The AROC is computed from the mean scores for the 7 subjects, obtained from the broadband signal from 25 electrodes from the whole cortex. The closer the AROC is to 0 or 1, the better the measure is at discriminating the given state-pair, close to 1 signifying that the measure tends to be greater for the more conscious state and close to 0 signifying that the measure tends to be greater for the less conscious state. When the AROC is 0.5 there is no discriminative power; hit rate equals false alarm rate for all classification thresholds. LZc, ACE and SCE have nearly maximal discriminative power for state pairs LOC/MS and LOC/WR. The measure sumCov fails to discriminate LOC/MS yet has strong (inverse) discriminative power for LOC/WR and MS/WR. Normalized delta band power discriminates LOC/WR and LOC/MS strongly yet MS/WR poorly.CC BY · PubMed Central
Fig 9 Pearson correlations between measures. Each black triangle indicates the positive correlation for the given measure pair listed in increasing order along the x-axis. The correlation was computed across subjects for the ratio of WR/LOC. Each correlation of all possible pairs of 9 measures was tested for significance and only those with 2-tailed p-value smaller than 0.05 are plotted. The red triangle indicates negative correlation. All 3 pairs out of ACE, LZc, SCE correlate significantly. There is no significant correlation of delta power with any other of the 9 measures for the state pair WR/LOC.
Fig 9 Pearson correlations between measures. Each black triangle indicates the positive correlation for the given measure pair listed in increasing order along the x-axis. The correlation was computed across subjects for the ratio of WR/LOC. Each correlation of all possible pairs of 9 measures was tested for significance and only those with 2-tailed p-value smaller than 0.05 are plotted. The red triangle indicates negative correlation. All 3 pairs out of ACE, LZc, SCE correlate significantly. There is no significant correlation of delta power with any other of the 9 measures for the state pair WR/LOC.CC BY · PubMed Central
Fig 10 Analysis of 25 k-medoids chosen electrodes for each of four lobes. Blue star is WR, red diamond is LOC. The red error bars indicate standard error. LZc and ACE score for all subjects higher for WR as opposed to LOC, SCE does so for 6/7 subjects. The measures behave similarly for different brain regions. If the effect size Cohen’s d < 0.8 for the scores of a given subject, the subject’s label is printed in red.
Fig 10 Analysis of 25 k-medoids chosen electrodes for each of four lobes. Blue star is WR, red diamond is LOC. The red error bars indicate standard error. LZc and ACE score for all subjects higher for WR as opposed to LOC, SCE does so for 6/7 subjects. The measures behave similarly for different brain regions. If the effect size Cohen’s d < 0.8 for the scores of a given subject, the subject’s label is printed in red.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 54 references

Cited by

See all 287

Metadata

Authors
Schartner, M., Seth, A., Noirhomme, Q., Boly, M., Bruno, M.-A., Laureys, S., & Barrett, A.
Affiliations
  • University of Sussex (GB)
  • University of Liège (BE)
Corresponding author
Schartner, Michael
Venue
PLOS ONE
Published
2015-08-07
Volume
10
Issue
8
Pages
e0133532
ISSN
1932-6203 (ISSN-L)
OpenAlex
W1957794009
Cited by
287
References
54
Citations by year
2026: 35 · 2025: 28 · 2024: 27 · 2023: 36 · 2022: 35 · 2021: 34 · 2020: 25 · 2019: 23 · 2018: 25 · 2017: 11 · 2016: 7
FWCI
8.61
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Sussex Research Online (University of Sussex) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Figshare (submittedVersion, cc-by)
  • Open Repository and Bibliography (University of Liège) (submittedVersion, cc-by)
Funders
  • James S. McDonnell Foundation
  • Mind Science Foundation
  • European Commission
  • University of Sussex
  • Université de Liège
  • Engineering and Physical Sciences Research Council (EP/G007543/1, EP/L005131/1)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Anesthesia and Sedative Agents
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
Keywords
spontaneous EEG, general anesthesia, propofol, neural complexity, Lempel-Ziv complexity, level of consciousness, EEG synchronization, theory of consciousness
MeSH terms
Anesthesia, General, Cerebral Cortex, Computer Simulation, Electrodes, Electroencephalography, Humans, Models, Theoretical, ROC Curve, Time Factors, Propofol, Entropy, Area Under Curve

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Complexity of Multi-Dimensional Spontaneous EEG Decreases during Propofol Induced General Anaesthesia. https://app.cochat.ai/papers/10.1371/journal.pone.0133532
The paper
Schartner, M., Seth, A., Noirhomme, Q., Boly, M., Bruno, M.-A., Laureys, S., & Barrett, A. (2015). Complexity of Multi-Dimensional Spontaneous EEG Decreases during Propofol Induced General Anaesthesia. PLOS ONE. https://doi.org/10.1371/journal.pone.0133532

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.