Pressure–Time Curve Predicts Minimally Injurious Ventilatory Strategy in an Isolated Rat Lung Model

Ranieri, V. Marco, Zhang, Haibo, Mascia, Luciana, Aubin, Michael, Lin, Chang-Yi, Mullen, J. Brendan, Grasso, Salvatore, Binnie, Matthew, Volgyesi, George A., Eng, P., Slutsky, Arthur S. · 2000 · Anesthesiology

Abstract

Background: We tested the hypothesis that the pressure-time (P-t) curve during constant flow ventilation can be used to set a noninjurious ventilatory strategy. Methods: In an isolated, nonperfused, lavaged model of acute lung injury, tidal volume and positive end-expiratory pressure were set to obtain: (1) a straight P-t curve (constant compliance, minimal stress); (2) a downward concavity in the P-t curve (increasing compliance, low volume stress); and (3) an upward concavity in the P-t curve (decreasing compliance, high volume stress). The P-t curve was fitted to: P = a. tb +c, where b describes the shape of the curve, b = 1 describes a straight P-t curve, b < 1 describes a downward concavity, and b > 1 describes an upward concavity. After 3 h, lungs were analyzed for histologic evidence of pulmonary damage and lavage concentration of inflammatory mediators. Ventilator-induced lung injury occurred when injury score and cytokine concentrations in the ventilated lungs were higher than those in 10 isolated lavaged rats kept statically inflated for 3 h with an airway pressure of 4 cm H2O. Results: The threshold value for coefficient b that discriminated best between lungs with and without histologic and inflammatory evidence of ventilator-induced lung injury (receiver-operating characteristic curve) ranged between 0.90-1.10. For such threshold values, the sensitivity of coefficient b to identify noninjurious ventilatory strategy was 1.00. A significant relation (P < 0.001) between values of coefficient b and injury score, interleukin-6, and macrophage inflammatory protein-2 was found. Conclusions: The predictive power of coefficient b to predict noninjurious ventilatory strategy in a model of acute lung injury is high.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-200011000-00027

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 198

Metadata

Authors
Ranieri, V. M., Zhang, H., Mascia, L., Aubin, M., Lin, C.-Y., Mullen, J. B., Grasso, S., Binnie, M., Volgyesi, G. A., Eng, P., & Slutsky, A. S.
Venue
Anesthesiology
Published
2000-11-01
Volume
93
Issue
5
Pages
1320-1328
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2073108089
Cited by
198
References
1
FWCI
7.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pressure–Time Curve Predicts Minimally Injurious Ventilatory Strategy in an Isolated Rat Lung Model. https://app.cochat.ai/papers/10.1097/00000542-200011000-00027
The paper
Ranieri, V. M., Zhang, H., Mascia, L., Aubin, M., Lin, C.-Y., Mullen, J. B., Grasso, S., Binnie, M., Volgyesi, G. A., Eng, P., & Slutsky, A. S. (2000). Pressure–Time Curve Predicts Minimally Injurious Ventilatory Strategy in an Isolated Rat Lung Model. Anesthesiology. https://doi.org/10.1097/00000542-200011000-00027

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.