Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 228

The DOI matches its Crossref record.

Changes in Blood Volume and Hematocrit during Acute Preoperative Volume Loading with 5% Albumin or 6% Hetastarch Solutions in Patients before Radical Hysterectomy

Rehm, Markus, Haller, Mathias, Orth, Victoria, Kreimeier, Uwe, Jacob, Mathias, Dressel, Holger, Mayer, Sabine, Brechtelsbauer, Heinz, Finsterer, Udilo · 2001 · Anesthesiology

Abstract

Background: The impact of acute preoperative volume loading with colloids on blood volume has not been investigated sufficiently. Methods: Before surgery, in 20 patients undergoing major gynecologic procedures, volume loading was performed during anesthesia by infusing approximately 20 ml/kg of colloid at a rate of 90 ml/min (group I: 5% albumin solution; group II: 6% hetastarch solution; n = 10 each). Plasma volume (indocyanine green dilution technique), erythrocyte volume (labeling erythrocytes with fluorescein), hematocrit, total protein, and hetastarch plasma concentrations (group II) were measured before and 30 min after the end of infusion. Results: More than 1,350 ml of colloid (approximately 50% of the baseline plasma volume) were infused within 15 min. Thirty minutes after the infusion had been completed, blood volume was only 524 +/- 328 ml (group I) and 603 +/- 314 ml (group II) higher than before volume loading. The large vessel hematocrit (measured by centrifugation) dropped more than the whole body hematocrit, which was derived from double-label measurements of blood volume. Conclusions: The double-label measurements of blood volume performed showed that 30 min after the infusion of approximately 20 ml/kg of 5% albumin or 6% hetastarch solution (within 15 min), only mean 38 +/- 21% and 43 +/- 26%, respectively, of the volume applied remained in the intravascular space. Different, i.e., earlier or later, measuring points, different infusion volumes, infusion rates, plasma substitutes, or possibly different tracers for plasma volume measurement might lead to different results concerning the kinetics of fluid or colloid extravasation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-200110000-00011

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 228

Metadata

Authors
Rehm, M., Haller, M., Orth, V., Kreimeier, U., Jacob, M., Dressel, H., Mayer, S., Brechtelsbauer, H., & Finsterer, U.
Venue
Anesthesiology
Published
2001-10-01
Volume
95
Issue
4
Pages
849-856
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2058698941
Cited by
228
References
0
FWCI
2.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Changes in Blood Volume and Hematocrit during Acute Preoperative Volume Loading with 5% Albumin or 6% Hetastarch Solutions in Patients before Radical Hysterectomy. https://app.cochat.ai/papers/10.1097/00000542-200110000-00011
The paper
Rehm, M., Haller, M., Orth, V., Kreimeier, U., Jacob, M., Dressel, H., Mayer, S., Brechtelsbauer, H., & Finsterer, U. (2001). Changes in Blood Volume and Hematocrit during Acute Preoperative Volume Loading with 5% Albumin or 6% Hetastarch Solutions in Patients before Radical Hysterectomy. Anesthesiology. https://doi.org/10.1097/00000542-200110000-00011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.