Changes in Blood Volume and Hematocrit during Acute Preoperative Volume Loading with 5% Albumin or 6% Hetastarch Solutions in Patients before Radical Hysterectomy
The DOI matches its Crossref record.
Abstract
Background: The impact of acute preoperative volume loading with colloids on blood volume has not been investigated sufficiently. Methods: Before surgery, in 20 patients undergoing major gynecologic procedures, volume loading was performed during anesthesia by infusing approximately 20 ml/kg of colloid at a rate of 90 ml/min (group I: 5% albumin solution; group II: 6% hetastarch solution; n = 10 each). Plasma volume (indocyanine green dilution technique), erythrocyte volume (labeling erythrocytes with fluorescein), hematocrit, total protein, and hetastarch plasma concentrations (group II) were measured before and 30 min after the end of infusion. Results: More than 1,350 ml of colloid (approximately 50% of the baseline plasma volume) were infused within 15 min. Thirty minutes after the infusion had been completed, blood volume was only 524 +/- 328 ml (group I) and 603 +/- 314 ml (group II) higher than before volume loading. The large vessel hematocrit (measured by centrifugation) dropped more than the whole body hematocrit, which was derived from double-label measurements of blood volume. Conclusions: The double-label measurements of blood volume performed showed that 30 min after the infusion of approximately 20 ml/kg of 5% albumin or 6% hetastarch solution (within 15 min), only mean 38 +/- 21% and 43 +/- 26%, respectively, of the volume applied remained in the intravascular space. Different, i.e., earlier or later, measuring points, different infusion volumes, infusion rates, plasma substitutes, or possibly different tracers for plasma volume measurement might lead to different results concerning the kinetics of fluid or colloid extravasation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Colloids versus crystalloids for fluid resuscitation in critically ill patients
Perel, P., Roberts, I., & Ker, K. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000567.pub6 · Cited by 1,115
A Rational Approach to Perioperative Fluid Management
Chappell, D., Jacob, M., Hofmann-Kiefer, K., Conzen, P., & Rehm, M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e3181863117 · Cited by 909
Self-citationWoodcock, T. E., & Woodcock, T. M. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aer515 · Cited by 806
Rehm, M., Bruegger, D., Christ, F., Conzen, P., Thiel, M., Jacob, M., Chappell, D., Stoeckelhuber, M., Welsch, U., Reichart, B., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.684852 · Cited by 669
Self-citationJohansson, P. I., Stensballe, J., Rasmussen, L. S., & Ostrowski, S. R. (2011) · Annals of Surgery · doi:10.1097/sla.0b013e318226113d · Cited by 554
Degradation of the endothelial glycocalyx in clinical settings: searching for the sheddases
Becker, B. F., Jacob, M., Leipert, S., Salmon, A. H. J., & Chappell, D. (2015) · British Journal of Clinical Pharmacology · doi:10.1111/bcp.12629 · Cited by 464
Self-citationThe endothelial glycocalyx: a review of the vascular barrier
Alphonsus, C. S., & Rodseth, R. N. (2014) · Anaesthesia · doi:10.1111/anae.12661 · Cited by 460
Therapeutic strategies targeting the endothelial glycocalyx: acute deficits, but great potential
Becker, B. F., Chappell, D., Bruegger, D., Annecke, T., & Jacob, M. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq137 · Cited by 438
Self-citationPerioperative Fluid Management Strategies in Major Surgery: A Stratified Meta-Analysis
Corcoran, T., Emma Joy Rhodes, J., Clarke, S., Myles, P. S., & Ho, K. M. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318240d6eb · Cited by 427
Microvascular blood viscosity in vivo and the endothelial surface layer
Pries, A. R., & Secomb, T. W. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00297.2005 · Cited by 349
Chappell, D., Bruegger, D., Potzel, J., Jacob, M., Brettner, F., Vogeser, M., Conzen, P., Becker, B. F., & Rehm, M. (2014) · Critical Care · doi:10.1186/s13054-014-0538-5 · Cited by 336
Self-citationMeta-analysis of standard, restrictive and supplemental fluid administration in colorectal surgery
Rahbari, N. N., Zimmermann, J. B., Schmidt, T., Koch, M., Weigand, M. A., & Weitz, J. (2009) · British Journal of Surgery · doi:10.1002/bjs.6552 · Cited by 321
Endothelial Glycocalyx: Permeability Barrier and Mechanosensor
Curry, F. E., & Adamson, R. H. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0429-8 · Cited by 312
Endothelial glycocalyx and coronary vascular permeability: the fringe benefit
Becker, B. F., Chappell, D., & Jacob, M. (2010) · Basic Research in Cardiology · doi:10.1007/s00395-010-0118-z · Cited by 277
Self-citationRehm, M., Zahler, S., Lötsch, M., Welsch, U., Conzen, P., Jacob, M., & Becker, B. F. (2004) · Anesthesiology · doi:10.1097/00000542-200405000-00025 · Cited by 276
Self-citationBruegger, D., Jacob, M., Rehm, M., Loetsch, M., Welsch, U., Conzen, P., & Becker, B. F. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00218.2005 · Cited by 265
Self-citationModulation of Endothelial Glycocalyx Structure under Inflammatory Conditions
Kolářová, H., Ambrůzová, B., Švihálková Šindlerová, L., Klinke, A., & Kubala, L. (2014) · Mediators of Inflammation · doi:10.1155/2014/694312 · Cited by 257
Damage of the endothelial glycocalyx in chronic kidney disease
Padberg, J.-S., Wiesinger, A., di Marco, G. S., Reuter, S., Grabner, A., Kentrup, D., Lukasz, A., Oberleithner, H., Pavenstädt, H., Brand, M., et al. (2014) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2014.03.016 · Cited by 241
Chappell, D., Jacob, M., Paul, O., Rehm, M., Welsch, U., Stoeckelhuber, M., Conzen, P., & Becker, B. F. (2009) · Circulation Research · doi:10.1161/circresaha.108.187831 · Cited by 218
Self-citationBlood Flow in Microvascular Networks
Pries, A. R., & Secomb, T. W. (2008) · Microcirculation · doi:10.1016/b978-0-12-374530-9.00001-2 · Cited by 213
Contrasting Effects of Colloid and Crystalloid Resuscitation Fluids on Cardiac Vascular Permeability
Jacob, M., Bruegger, D., Rehm, M., Welsch, U., Conzen, P., & Becker, B. F. (2006) · Anesthesiology · doi:10.1097/00000542-200606000-00018 · Cited by 210
Self-citationColloids versus crystalloids for fluid resuscitation in critically ill patients
Perel, P., & Roberts, I. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000567.pub5 · Cited by 191
Lobo, D. N., Stanga, Z., Aloysius, M. M., Wicks, C., Nunes, Q. M., Ingram, K. L., Risch, L., & Allison, S. P. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181bc80f1 · Cited by 191
“In an experiment on acute normovolemic hemodilution during anesthesia for major gynecologic surgery, Rehm et al (26) showed a lower increase in plasma volume (using fluorescein-labeled red blood cells) post colloidal infusion than in our study.”
ResultJACOB, M., BRUEGGER, D., REHM, M., STOECKELHUBER, M., WELSCH, U., CONZEN, P., & BECKER, B. (2007) · Cardiovascular Research · doi:10.1016/j.cardiores.2006.11.021 · Cited by 180
“[23]). This “COP paradox” is of practical importance, due to a very frequent but indiscriminant use of different colloids in clinical settings, all being assumed to maintain plasma volume simply on the basis of their COP [ 24 ].”
BackgroundSelf-citationColloids versus crystalloids for fluid resuscitation in critically ill patients
Perel, P., Roberts, I., & Pearson, M. (2007) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000567.pub3 · Cited by 179
Nanomechanics of the Endothelial Glycocalyx in Experimental Sepsis
Wiesinger, A., Peters, W., Chappell, D., Kentrup, D., Reuter, S., Pavenstädt, H., Oberleithner, H., & Kümpers, P. (2013) · PLoS ONE · doi:10.1371/journal.pone.0080905 · Cited by 170
“Along with various incorporated proteins of plasmatic and endothelial origin, the eGC attains thickness of up to 2 μm and thus is considerably thicker than the endothelial cells themselves [9,11-15].”
BackgroundThe impact of the glycocalyx on microcirculatory oxygen distribution in critical illness
Chappell, D., Westphal, M., & Jacob, M. (2009) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0b013e328328d1b6 · Cited by 161
Self-citationThe ‘third space’ – fact or fiction?
Jacob, M., Chappell, D., & Rehm, M. (2009) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2009.05.001 · Cited by 159
Self-citationJacob, M., Chappell, D., Hofmann-Kiefer, K., Conzen, P., Peter, K., & Rehm, M. (2007) · Der Anaesthesist · doi:10.1007/s00101-007-1235-4 · Cited by 51
Self-citation
Metadata
- Authors
- Rehm, M., Haller, M., Orth, V., Kreimeier, U., Jacob, M., Dressel, H., Mayer, S., Brechtelsbauer, H., & Finsterer, U.
- Venue
- Anesthesiology
- Published
- 2001-10-01
- Volume
- 95
- Issue
- 4
- Pages
- 849-856
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2058698941
- Cited by
- 228
- References
- 0
- FWCI
- 2.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.