CoChat

Sample Size Calculations in Clinical Research

Open access
Bacchetti, Peter, Leung, Jacqueline M. · 2002 · Anesthesiology
Cited by 199

The DOI matches its Crossref record.

Abstract

To the Editor:—We write to make the case that the practice of providing a priori sample size calculations, recently endorsed in an Anesthesiology editorial, 1is in fact undesirable. Presentation of confidence intervals serves the same purpose, but is superior because it more accurately reflects the actual data, is simpler to present, addresses uncertainty more directly, and encourages more careful interpretation of results. The clinical trial report 2lauded in the editorial in fact serves to illustrate the drawbacks of sample size calculation as a data analysis tool. The a priori calculation presented is based on assumptions about length of stay (normally distributed with a SD of 4.5 days) that did not hold in the actual data, an analysis (comparison of mean length of stay between two groups by t test) that was not presented, and a sample size that was not attained. It therefore does not help the reader interpret the results, which is the proper goal when reporting on a study that has been completed. The post hoc power calculation presented retains most of these deficiencies, and therefore does not help the reader to assess the strength of evidence against a 1.0-day mean advantage for one treatment versus another. In contrast, a confidence interval for the difference in means would directly address this issue. Although the presence of outliers would require a bootstrapping method 3to obtain a valid confidence interval for a difference in means, this bit of extra effort is certainly worthwhile for the central issue of a study, and in any case, much better than relying on convoluted reasoning with invalid power approximations.Perhaps the worst aspect of reporting sample size or power calculations is that it encourages interpretation of studies’ results based only on P values, in particular the widespread fallacy of interpreting P > 0.05 as proving the null hypothesis. The other article 4cited by the editorial provides a glaring example of this type of reasoning, concluding that reporting of sample size calculations did not change over time in any journal but did increase overall (see their fig. 2). Returning to the clinical trial report, consider the statement that death rates “were similar” in the four subgroups. While this is an accurate characterization of what was actually observed, unsophisticated readers are liable to interpret this (contrary to the authors’ intentions) to mean that the study found strong evidence against any substantial difference in death rates. In fact, the exact 595% confidence interval around the odds ratio for death comparing intravenous versus epidural postoperative analgesia goes from 0.36 to 5.4, which is wide enough to make clear to most readers that this study by itself provides only very weak evidence against a clinically important difference in death rates.We urge reviewers, editors, and quality studies to give authors full credit for providing confidence intervals instead of sample size calculations in reports of completed studies. Indeed, for the reasons illustrated here, it would be best to discourage the practice of using sample size and power calculations as substitutes for more direct assessment of uncertainty using confidence intervals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-200210000-00050

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 199

Metadata

Authors
Bacchetti, P., & Leung, J. M.
Venue
Anesthesiology
Published
2002-10-01
Volume
97
Issue
4
Pages
1028-1029
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2057517520
Cited by
199
References
0
FWCI
0.36
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sample Size Calculations in Clinical Research. https://app.cochat.ai/papers/10.1097/00000542-200210000-00050
The paper
Bacchetti, P., & Leung, J. M. (2002). Sample Size Calculations in Clinical Research. Anesthesiology. https://doi.org/10.1097/00000542-200210000-00050

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.