Cricoid Pressure Displaces the Esophagus: An Observational Study Using Magnetic Resonance Imaging
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Background: Cricoid pressure (CP) is often used during general anesthesia induction to prevent passive regurgitation of gastric contents. The authors used magnetic resonance imaging to determine the anatomic relationship between the esophagus and the cricoid cartilage ("cricoid") with and without CP. Methods: Magnetic resonance images of the necks of 22 healthy volunteers were reviewed with and without CP. Esophageal and airway dimensions, distance between the midline of the vertebral body and the midline of the esophagus, and distance between the lateral border of the cricoid or vertebral body and the lateral border of the esophagus were measured. Results: The esophagus was displaced laterally relative to the cricoid in 52.6% of necks without CP and 90.5% with CP. CP shifted the esophagus relative to its initial position to the left in 68.4% of subjects and to the right in 21.1% of subjects. Unopposed esophagus was seen in 47.4% of necks without CP and 71.4% with CP. Lateral laryngeal displacement and airway compression were demonstrated in 66.7% and 81.0% of necks, respectively, as a result of CP. Conclusion: In the absence of CP, the esophagus was lateral to the cricoid in more than 50% of the sample. CP further displaced both the esophagus and the larynx laterally.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Netter, F. H. (1974) · Virtual Defense Library (Ministerio de Defensa) · doi:10.5281/zenodo.5507198 · Cited by 1,215
If Nothing Goes Wrong, Is Everything All Right?: Interpreting Zero Numerators
Hanley, J. A. (1983) · JAMA · doi:10.1001/jama.1983.03330370053031 · Cited by 1,043
CRICOID PRESSURE TO CONTROL REGURGITATION OF STOMACH CONTENTS DURING INDUCTION OF ANÆSTHESIA
Sellick, B. A. (1961) · The Lancet · doi:10.1016/s0140-6736(61)92485-0 · Cited by 951
Airway obstruction with cricoid pressure
Hartsilver, E. L., & Vanner, R. G. (2000) · Anaesthesia · doi:10.1046/j.1365-2044.2000.01205.x · Cited by 198
Cricoid pressure: knowledge and performance amongst anaesthetic assistants
Meek, T., Gittins, N., & Duggan, J. E. (1999) · Anaesthesia · doi:10.1046/j.1365-2044.1999.00706.x · Cited by 129 · cited 1×
“This method has been used to reproduce accurate amounts of CP previously.(4,5) Because of spatial limitations of the MRI machine, the investigator applied CP using a two-handed technique while positioned at the head of the MRI table.”
MethodThe cricoid cartilage and the esophagus are not aligned in close to half of adult patients
Smith, K. J., Ladak, S., Choi, P. T. L., & Dobranowski, J. (2002) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03017931 · Cited by 79 · cited 2×
“Furthermore, the esophagus was displaced laterally in more than one half of the subjects, which is similar to the results seen in previous studies of normal necks without CP using computed tomography and MRI.(7,13) Below the level of the cricoid, the esophagus is expected to travel to the left of midline.”
MethodResultSelf-citationHoyte, L. P. J., & Ratiu, P. (2001) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2001.116751 · Cited by 25 · cited 3×
“To determine the interrater agreement for measurements, we defined an allowable measurement error of 2.0 mm, assuming an average esophageal diameter of approximately 15.0 mm, as a representative reproducible measurement based on a study demonstrating up to 15% measurement variability using MRI.11 Of the images selecte…”
MethodInfluential
Cited by
Preoxygenation and prevention of desaturation during emergency airway management
Weingart, S. D., & Levitan, R. M. (2012) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2011.10.002 · Cited by 554
“Computed tomography and magnetic resonance imaging scanning have shown that cricoid pressure causes lateral displacement of the esophagus in more than 90% of patients and laryngeal/tracheal compression in 80%.(87,88) Numerous ventilation studies have found that cricoid pressure hinders bagvalve-mask device ventilation…”
BackgroundThe difficult airway with recommendations for management – Part 2 – The anticipated difficult airway
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0020-x · Cited by 276
Rapid Sequence Induction and Intubation: Current Controversy
El-Orbany, M., & Connolly, L. A. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181d5ae47 · Cited by 239
“Incorrect timing, the use of excessive force, and compressing the thyroid cartilage instead of the cricoid cartilage are examples of misuse of CP. Advocates also stress the added benefit of the ability of CP to prevent gastric insufflation when mask ventilation is needed before tracheal intubation, which may frequentl…”
BackgroundInfluentialSakai, T., Planinsic, R. M., Quinlan, J. J., Handley, L. J., Kim, T.-Y., & Hilmi, I. A. (2006) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000237296.57941.e7 · Cited by 196
““Proper” cricoid pressure application is often difficult in terms of the force needed to occlude the upper portion of the esophagus because of the anatomical alignment of the larynx and the esophagus ( 7 ).”
BackgroundLipman, S., Cohen, S., Einav, S., Jeejeebhoy, F., Mhyre, J. M., Morrison, L. J., Katz, V., Tsen, L. C., Daniels, K., Halamek, L. P., et al. (2014) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000171 · Cited by 190
Metadata
- Authors
- Smith, K. J., Dobranowski, J., Yip, G., Dauphin, A., & Choi, P. T.-L.
- Venue
- Anesthesiology
- Published
- 2003-07-01
- Volume
- 99
- Issue
- 1
- Pages
- 60-64
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2119612388
- Cited by
- 219
- References
- 7
- FWCI
- 5.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.